Low Frequency 3 Phase Online UPS 10KVA - 400KVA With RS232

Categories 3 Phase Online UPS
Place of Origin: Shenzhen China
Brand Name: HRD/OEM/ODM
Certification: CE, ISO9001:2008
Model Number: PV3310II,PV3320I,PV3330III,,, PV33200II, PV33300II, PV33400II
MOQ: 1PCS
Price: Negotiable
Packaging Details: wooden case with pallet
Delivery Time: 3 weeks after down payment
Payment Terms: TT
Supply Ability: 500pcs/ month
Warranty: 2-3 years after shipment with 10years technical support
Product Name: online ups system
Rate frequency: 50 / 60 Hz auto-sense
Output PF: 0.8(lag)
System efficiency (ECO mode): 98%(@100%load)
System efficiency (inverter mode): 92%(@100% load) ;90% @50%load;
Communication interface: Standard RS232,optional: RS485 / MODBUS
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Low Frequency 3 Phase Online UPS 10KVA - 400KVA With RS232

    Low Frequency 3 Phase Online UPS 10KVA - 400KVA With RS232

    Introduction: Powervalue (Ⅱ) is upgraded DSP controlled Online LF UPS with output isolation transformer. It can be your perfect large capacity power shield for your critical and industrial load.

    QUALITY POWER SUPPLY


    HRD PV(II)series is an On-Line double conversion (VFI) UPS with isolation output transformer, unit capacity from 10KVA to 400KVA. It is immune to the interferences on the electric power supply line as it has special input and output filters. World leading DSP technology, with high speed DSP processor 32bits,are adopted to guarantee system’s high stability and giving stable output power supply for all kinds of harsh load.

    PERFECT APPLICAITON: Middle and large data center, Telecom, Finance, Traffic, Defense, Medical, Education, Energy, Manufacture, Industry, etc.

    MAXIMUM RELIABILITY


    The advanced DPS technology appliance considerably improves reliability, since a reduction in electronic components lowers the likelihood of breakdowns. Digital control is provided by the microprocessor that, in the PV(II) series controls all the internal parameters, thus increasing reliability and performance. In parallel connections, digital control ensures balance of the currents, which generally change over time due to phenomena such as vibrations and temperature, between the UPS units and the exchange of information with no need for manual tuning. MTBF >200,000h.PV(II) has been designed so that it can be connected in parallel even after the installation of the first unit. The power availability can be increased thanks to various configurations available such as the parallel configuration, the Dual Bus function and the Dynamic Dual Bus system.

    HIGH SPEED DSP PROCESSOR: Ensuring the operation more fast and stable

    OUTPUT 100% UNBALANCE LOAD


    The ups can accept 3phase 100% unbalance load to satisfy kinds of load configuration.

    ECO function: under good power condition, UPS can work in ECO mode, efficiency reach 98%, green and energy saving;

    UPS FOR INDUSTRIAL LOADS


    PV-Plus with its strong overload capability, output galvanic isolation and low harmonic current distortion, is the ideal solution for industrial applications.

    Thanks to the high battery current, PV Plus Series is suitable to work with large battery banks as it can guarantee recharging in 10 hours as recommended by the battery manufacturer.

    OPERATING FLEXIBILITY:All power ratings of the PV(II) series can also be used as Frequency Converters 50 to 60 Hz and vice versa.

    COLORFUL MULTIFUCTIONAL PANEL


    The 7 inch colorful multifunctional panel allows easy and humanized operation of the UPS. It gives access to the most important parameters: status and alarms, control commands, input, output, battery measurements (power, current, voltage, frequency and temperature) and settings. The PV(II) series’ diagnostics system includes up to 128 alarms or messages allowing precise and detailed identification of any event.

    Advanced Battery Management (ABM)


    Optimal battery management includes:

    • Periodic battery test, and automatically transfer between boost charging and float charging to extend battery lifespan
    • Automatically adjusting the battery charging current according to battery capacity
    • Recharge temperature compensation (optional)
    • Remaining back up time display

    MAXIMUM SAFETY FOR PERSONNEL


    The back feed protection device prevents any voltage back feed in the upstream distribution board, thus ensuring the safety of the maintenance personnel.

    FULL FRONT ACCESS AND CONVENIENT CABLE CONNECTION


    Full frontal access is for all power and electronic components, which reduces the floor space required and consequently reduces the installation costs.

    Configured with top and bottom cable connection

    PERFECT HUMAN-MACHINE COMMUNICATION


    UPS Monitor software displays the most important information such as the input and output voltage, the load applied, the remaining back-up time, etc., in the form of bar graphs. The software is able to provide information even in the event of a failure, in support of the fault diagnostics. The UPS Monitor software can be used to program the automatic shutdown of all open systems in the event of a prolonged black out. PV Plus can also operate with a network agent for applications on LAN or WAN networks.

    The UPS contains the following hardware interfaces:

    • RS232 /RS485 interface,
    • Dry contacts: battery low,battery discharge,bypass/breakdown
    • EPO (Emergency Power Off) contact for UPS shutdown using the remote emergency button.
    • SNMP card(optional)

    ADVANCED PARALLEL


    Maximum parallel up to 8 units and share the common battery pack.10-80kva parallel with parallel card only ; 100kva-400kva, parallel card with weaver reactance and different capacity UPS can be also be parallel;

    DYNAMIC DUAL BUS SYSTEM


    Two independent systems set in Dual Bus Configuration can be merged together at any time for system expansion or maintenance. This provides a lot of flexibility in your installation in case of maintenance or when it is necessary to change the redundancy level of both systems.

    EVENT LOG: 1000 historical events can be saved, which is easy for tracing ups operation status and useful for maintenance

    Technical specification:

    1) 10-120KVA specification:

    Model

    PV3310ii

    PV3315ii

    PV3320ii

    PV3330ii

    PV3340ii

    PV3360ii

    PV3380ii

    PV33100ii

    PV33120ii

    Capacity

    10KVA

    15KVA

    20KVA

    30KVA

    40KVA

    60KVA

    80KVA

    100KVA

    120KVA

    system

    Output PF

    0.8(lag)

    System efficiency (inverter mode)

    92%(@100% load) ;90% @50%load;

    System efficiency (ECO mode)

    98%(@100%load)

    Maximum leakage current

    100(mA)

    MTBF

    Above 200,000hours

    Dry contact

    Standard: 3 types signal(BAT. low,battery mode,bypass /failure);

    Optional:14 dry contact ; output: 12Vdc 80mA

    Communication interface

    Standard RS232,optional: RS485 / MODBUS

    Operation temperature

    0 ~ 40 °C

    Humidity

    95 % (non-condense)

    Cooling

    Forced air(speed varying according to load percent)

    Max. altitude

    Within 1000m(every 100increase,capacity decrease -1%),Maximum 4000m

    Noise (dB)

    52 ~ 58

    IP protection

    (EN 60529)

    IP20

    Input/output way

    Bottom /rear

    Safety standard

    safety:GB4943 ,EN 50091-1;EMI:GB7260.2,GB/T 17626.2~5EMC, EN 50091-2

    Physical

    W *D*H(mm)

    600*600*1280

    800*800*1480

    800*800*1800

    Weight(Kg)

    195

    210

    220

    305

    340

    500

    600

    800

    950

    AC input

    Rated voltage

    380/400/415VAC Three-phase three-wire

    Input voltage range

    ± 15 %- ± 25 % adjustable)

    Rate frequency

    50 / 60 Hz auto-sense

    Frequency range

    50/60Hz+/-5Hz

    Input soft start function

    0 - 100%,10-300s(settable)

    Input power factor

    Reachable 0.99(plus harmonic filter)

    Input current harmonic component(THDi )

    Can <5%(plus harmonic filter)

    Max. input current [A]

    18

    27

    36

    54

    72

    108

    144

    180

    216

    The output characteristic of the rectifier

    Maintain the voltage (20°C)

    Battery type1 and 2 :V =435Vdc (2.266 x el.)

    Battery type 3 :V =424Vdc (2.21 x el.)

    Battery type 0:the voltage value between type 1and 2,

    Voltage regulating range: V =400~460Vdc

    Charging voltage (20°C)

    Battery type1 and 2 :V (%recharging<95%) = 445Vdc (2.32 x el.)

    Battery type 3 :V (%recharging<95%) = 460Vdc (2.4 x el.)

    Battery type 0: the voltage value between type 1and 2,

    Voltage regulating range: V =400~460Vdc

    The highest charging voltage

    445V

    The charger output voltage regulation accuracy

    1%

    DC ripple voltage component

    ≤1%

    Battery

    Unit number(rated voltage)

    384VDC(360-384v,selectable)

    Charging current settings

    0.1C(battery capacity)

    The battery discharge end voltage

    Battery type 1,2 and 3:no-load discharge current,V min=346 [V dc]

    Battery type 1,2 and 3:output current =Ah capacity,V min=316 [V dc]

    Battery type 1,2 and 3:output current >Ah capacity,V min=306 [V dc]

    Battery type 0: the factory set the default values,V min=320 [V dc]

    Regulating range: V min =300~360[V dc]

    Inverter output

    Rated capacity [KVA]

    10

    15

    20

    30

    40

    60

    80

    100

    120

    Rated power [KW]

    8

    12

    16

    24

    32

    48

    64

    80

    96

    Rated voltage [V]

    380/400/415VAC three-phase four-wire

    Rated current [A]

    12

    18

    24

    36

    48

    72

    96

    120

    144

    Phase voltage setting

    200 ~ 244 V (control board)

    Peak factor

    3:1

    Waveform

    Sine wave

    Voltage phase shift (degrees) 100% balanced load

    ± 1'

    Voltage phase shift (degrees)

    100% unbalanced load

    ± 2'

    Phase voltage difference 100% balance load

    ± 1 %

    Phase voltage difference 100% unbalanced load

    ± 3 %

    Total harmonic content(THD v) 100% linear load

    <2%

    Total harmonic content(THD v) 100% non-linear load

    <5%

    Steady-state voltage stability

    ± 1 %

    Transient voltage response

    ± 5 % within 10ms

    Rated frequency

    Same as input

    Frequency stability

    When asynchronous,± 0.5 %;synchronization,± 2 %

    (can be set to ± 1~5 %,by the panel operation)

    Overload

    600’ / 10’ / 1’ (110/125/150% rated current)

    Short circuit 0.1s

    Double input

    Inverter efficiency (load 100%)

    98%

    Bypass

    Rated capacity [KVA]

    10

    15

    20

    30

    40

    60

    80

    100

    120

    Rated voltage [V]

    380/400/415VAC Three-phase four-wire

    Input voltage range

    ±15 %(can be adjusted from the control panel ± 10 %,± 20%)

    Rated frequency [Hz]

    50 / 60

    Frequency range

    ±2 %(can be adjusted from the control panel ± 5 %)

    “STAND-BY ON”(Eco mode, the bypass switch to inverter)transfer time

    2~5ms

    Inverter/bypass transfer time

    <1ms

    Overload

    10’/1’/18” (150/175/200% Rated current)

    Standard configuration

    Feed flow protection, bypass independently isolated

    2) 160-400KVA product specification parameter table:

    Model

    PV33160 ii

    PV33200 ii

    PV33250 ii

    PV33300 ii

    PV33350 ii

    PV33400 ii

    Capacity

    160KVA

    200KVA

    250KVA

    300KVA

    350KVA

    400KVA

    6 pulse

    12 pulse

    6 pulse

    12 pulse

    6 pulse

    12 pulse

    6 pulse

    12 pulse

    6 pulse

    12 pulse

    6 pulse

    12 pulse

    System parameter

    Output power factor

     0.8(lag)

    Overall efficiency (normal model) Load 100%

    94%

    Load 50%

    92%

    Overall efficiency:

    (ECO mode) Load 100%

    98%

    Maximum leakage current(mA)

    100

    Standby economic model

    Standard functions

    Mean time before failure(MTBF)

    Above 200,000 hours

    Dry contact signal

    Standard three control signal (battery low,battery discharge,bypass/breakdown);

    Optional 14 control signal;output 12Vdc 80mA

    Computer monitors port

    Standard S232,optional ODBUS

    Running temperature

    0 ~ 40 °C

    Maximum relative humidity

    95 % (non-condensing)

    Cooling

    Forced ventilation (fan speed changing with load)

    Maximum altitude

    1000m rated power(Rising 100m lower 1%) maximum 4000m

    Noise dB

    54 ~ 62

    Protection class

    (EN 60529)

    IP20

    Inlet and outlet of the wire way

    Bottom /rear

    Safety standard

    Safety: GB4943,EN 50091-1;electromagnetic compatibility: GB7260.2,

    GB/T 17626.2~5EMC,EN 50091-2

    Physical parameter

    Wide (mm)

    1100

    1400

    1100

    1400

    1400

    1400

    1400

    1400

    1600

    1600

    1600

    1600

    Deep*high (mm)

    800*1800

    1000*2000

    1100*2000

    Weight(kg)

    1200

    1550

    1350

    1750

    1500

    1950

    1650

    2150

    1850

    2400

    2100

    2700

    The input rectifier features

    Rated voltage

    380/400/415VAC Three-phase three wire

    Voltage range

    ± 15 % (± 25 % adjustable)

    Rated frequency

    50 / 60 Hz automatic identification

    Frequency range

    45 ~ 65

    Input power

    slow start function

    Yes,0 - 100%,can be set to 10-300 seconds

    Input power factors cosφ

    Reachable 0.99(plus harmonic filter)

    Input current harmonic component(THDi )

    can<5%(plus harmonic filter)

    Max.input current [A]

    250

    315

    400

    500

    550

    630

    The output characteristic of the rectifier

    Maintain the voltage (20°C)

    Battery type1 and 2 :V =435Vdc (2.266 x el.)

    Battery type1 and 2 :

    V =544Vdc (2.266 x el.)

    Battery type 3 :V =424Vdc (2.21 x el.)

    Battery type 3 :

    V =530Vdc (2.21 x el.)

    Battery type 0:the voltage value between type 1 and 2,

    Voltage regulating range: V =400~460Vdc

    Battery type 0:the voltage value between type 1 and 2, Voltage regulating range:

    V =500~575Vdc

    Charging voltage (20°C)

    Battery type1 and 2 :V (%recharging<95%)=445Vdc (2.32 x el.)

    Battery type1 and 2 : V (%recharging<95%)

    =557Vdc (2.32 x el.)

    Battery type 3 :V (%recharging<95%)=460Vdc (2.4 x el.)

    Battery type 3 :V (%recharging<95%)

    =576Vdc (2.4 x el.)

    Battery type 0:the voltage value between type 1 and 2,

    Voltage regulating range: V =400~460Vdc

    Battery type 0:the voltage value between type 1 and 2, Voltage regulating range:

    V =500~575Vdc

    The highest charging voltage

    445V

    556V

    The charger output voltage regulation accuracy

    1%

    DC ripple voltage component

    ≤1%

    Battery

    Unit number(rated voltage)

    192 units(384VDC)

    240 units(480VDC)

    Charging current settings

    0.1 C(battery capacity)

    The battery discharge end voltage

    Battery type 1,2 and 3:no-load discharge current,

    Vmin=346 [V dc]

    Battery type 1,2 and 3:no-load discharge current,Vmin=433 [V dc]

    Battery type1,2 and 3:output current =Ah capacity,

    Vmin=316 [V dc]

    Battery type 1,2 and 3:

    output current =Ah capacity,

    Vmin=395 [V dc]

    Battery type 1,2,3:output current >Ah capacity,

    Vmin=306 [V dc]

    Battery type 1,2 and 3:

    output current >Ah capacity,

    Vmin=383 [V dc]

    Battery type 0:the factory set the default values,Vmin=320 [Vdc] Regulating range: Vmin =300~360V[V dc]

    Battery type 0:the factory set the default values,Vmin=400 [V dc] Regulating range:

    Vmin =375~450V[V dc]

    Inverter output

    Rated capacity [KVA]

    160

    200

    250

    300

    350

    400

    Rated power [KW]

    128

    160

    200

    240

    280

    320

    Rated voltage [V]

    380/400/415VAC three-phase four-wire

    Rated current [A]

    195

    243

    304

    365

    426

    486

    Phase voltage setting

    200 ~ 244 V (control board)

    Peak factor

    3:1

    Waveform

    Sine wave

    Voltage phase shift (degrees) 100% balanced load

    ± 1'

    Voltage phase shift (degrees)

    100% unbalanced load

    ± 2'

    Phase voltage difference 100% balance load

    ± 1 %

    Phase voltage difference 100% unbalanced load

    ± 3 %

    Total harmonic content(THD v) 100% linear load

    <2%

    Total harmonic content(THD v) 100% non-linear load

    <5%

    Steady-state voltage stability

    ± 1 %

    Transient voltage response

    ± 5 % within 10ms

    Rated frequency

    Same as input

    Frequency stability

    When asynchronous,± 0.5 %;synchronization,± 2 %

    can be set to ± 1~5 %,by the panel operation)

    Overload

    600’ / 10’ / 1’ (110/125/150% rated current)

    Short circuit 0.1s

    Double input

    Inverter efficiency (load 100%)

    98%

    Bypass

    Rated capacity [KVA]

    160

    200

    250

    300

    350

    400

    Rated voltage [V]

    380/400/415VAC three-phase four-wire

    Input voltage range

    ±15 %(can be adjusted from the control panel± 10 %,± 20%)

    Rated frequency [Hz]

    50 / 60

    Frequency range

    ±2 %(can be adjusted from the control panel± 5 %)

    “STAND-BY ON”(Economic mode, the bypass switch to inverter)conversion time

    2~5ms

    Inverter/bypass transfer time

    <1ms

    Overload

    10’/1’/18” (150/175/200% rated current)

    Standard configuration

    Feed flow protection, bypass independently isolated

    NOTE: 120VAC power grid 10-200kva are available;

    Quality Low Frequency 3 Phase Online UPS 10KVA - 400KVA With RS232 for sale
    Send your message to this supplier
     
    *From:
    *To: Shenzhen HRD SCI&TECH CO.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 bjjsgy.com. All rights reserved.