Low Noise Residential Heat Pump System / Air Source Heat Pump Air Conditioning

Categories Residential Air Source Heat Pump
Brand Name: Yushen
Model Number: SDNA-075Y
Certification: CCC, ISO, CQC
Place of Origin: China
MOQ: 1 set
Price: negotiable
Payment Terms: T/T
Supply Ability: 10 sets/day
Delivery Time: 1-2weeks
Packaging Details: Reinforced Carton box with wooden tray
Name: Residential Heat Pump System
Compressor capacity: 25HP per sets
Feature: Low Noise
Service area: 21900M2
average indoor temeprature: 20C
Type: Air Source Heat Pump Air Conditioning
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Low Noise Residential Heat Pump System / Air Source Heat Pump Air Conditioning

    Low Noise Residential Heat Pump System / Air Source Heat Pump Air Conditioning


    What is Residential Heat Pump System




    Residential Heat Pump System (ASHP) is a system which transfers heat from outside to inside a building, or vice versa. Under the principles of vapor compression refrigeration, an ASHP uses a refrigerant system involving a compressor and a condenser to absorb heat at one place and release it at another. They can be used as a space heater or cooler, and are sometimes called "reverse-cycle air conditioners".

    In domestic heating use, an ASHP absorbs heat from outside air and releases it inside the building, as hot air, hot water-filled radiators, underfloor heating and/or domestic hot water supply. The same system can often do the reverse in summer, cooling the inside of the house. When correctly specified, an ASHP can offer a full central heating solution and domestic hot water



    Residential Heat Pump System Project Brief

    Project locationJinan , Shandong province
    Total Building area21900M2
    Quantity of air-source heat pump21 sets
    ModelSDNA-075Y(25HP)
    System designultra low temperature air source heat pump+radiator heating

    Residential Heat Pump System Project Overview:
    This is one of our many community heating projects. The building area of this community is 36,500 m2 and the heating area is 2,1900 m2. The buildings are energy-efficient buildings. They have been put into use in 2015, stable, reliable and efficient operation. The average indoor temperature is around 20 °C. The area consumes about 28 KWH of electricity. According to the calculation of raw coal commonly used by users, the annual savings of raw coal can be about 484 tons, SO2 is reduced by about 8.3 tons, CO2 is reduced by about 870 tons, and ash and slag emissions are reduced by about 145 tons.

    Residential Heat Pump System information


    ModelSDNA-075Ycode name.pdf
    Compressor capacity25HP
    FunctionHeat
    Electricity380V 3N-50Hz
    Working conditions-25~+45
    DataHeataNominal capacityKW44.5
    Input powerKW18.3
    COP/2.4
    Heating IPLV(H)2.7
    A7W35cKW/COP75.0/4.2
    A2W35KW/COP62.5/3.20
    A-7W35KW/COP52.5/3.0
    A-15W55KW/COP45.5 /1.97
    A-20W45KW/COP37.4/2.04
    Max. running currencyA56
    Compressor quantityset2
    Refrigerant/charging quantity kg/R22/10*2
    Air blow type/Top
    Water pipe diametermm50
    Rating flowm³/h12.6
    Water side pressure losskPa≤45
    Noise leveldB(A)62
    Overall dimensions(L×W×H)mm2100×1100×2080
    Weightkg730

    a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity

    A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃


    Yushen Products Core Advantages

    • Yushen air source heat pump is 35% more powerful than other products, long heating time and less defrosting time
    • It could work in extreme environment /Suitable for environmental temperature:-25℃ to +45 ℃ /-13℉ to 113 ℉
    • No capacity decay under low temperature, keep high COP in winter

    Knowlege of Air Source Heat Pump

    When properly installed, anair-source heat pump can deliver one-and-a-half tothree times more heat energy to a home than theelectrical energy it consumes. This is possible becausea heat pump moves heat rather than converting it from fuel like combustion heating systems do.


    Comparasion to common AC unit

    ItemsAir source heat pumpAir conditioner unit
    When heating40% energy saving than Ac---
    When coolingEqual energy consumptionEqual
    InstallationEasyeasy
    MaintenanceLittlesome
    Suitable for EnderAC fans, under floor,radiatorAC fans only
    ExtraHot waterno

    Quality Low Noise Residential Heat Pump System / Air Source Heat Pump Air Conditioning for sale
    Send your message to this supplier
     
    *From:
    *To: Shandong Yushen Energy Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    You May Like
      Inquiry Cart 0

      Friendly Links: www.everychina.com

      Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

      Copyright © 2009 - 2024 bjjsgy.com. All rights reserved.