Preliminary Testing force: 98.07N,tolerance ±2.0%
Testing force: 588.4N, 980.7N, 1471N , tolerance ±1.0%
Hardness Measuring range: HRA:20-88、HRB:20-100、HRC:20-70、HRD:40-77、HRE:70-100、 HRF:60-100、HRG:30-94、HRH:80-100、HRK:40-100
Testing Force Application Mode: Manual operation
Indenter specification: Diamond cone Rockwell indenter,Φ1.5875mm steel ball indenter
Display: Mechanical dial
Indication error: 0.1HR
Indicator scale: 0~100(C),30~130(B)
Rockwell scale: HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRH、HRK
Maximum height of specimen: 170mm
Distance of Indenter to outer wall: 135mm
Dimension: 510×212×700mm
Main unit weight: 85kg
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Mitech MHR-150A High accuracy Durable High quality and inexpensive Manual Rockwell Hardness Tester

    Mitech MHR-150A Manual Rockwell Hardness Tester

    Overview

    Mitech MHR-150A Manual Rockwell Hardness Tester, based on the mechanical principle of conical diamond or hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the depth of the indentation. Capable of inspecting the finished or semi-finished parts of the machined sample, it is suitable for high accuracy hardness testing for batches parts with various metal or non-metallic materials. According to statistics, Rockwell hardness testing is the most widely used hardness testing method in metal processing industry, which utilization ratio is more than 70%. With novel appearance, stable performance and convenient visual reading of the classical dial, It is widely used in metal processing and manufacturing, various metal material’s failure analysis and other fields like colleges and research institutions. It is the new type Brinell hardness testing instrument for testing the hardness of the materials like cast iron, steel, soft alloy and so on.

    Technical Parameters

    Technical specificationsTechnical Parameters
    Preliminary Testing force98.07N,tolerance ±2.0%
    Testing force588.4N, 980.7N, 1471N , tolerance ±1.0%
    Hardness Measuring range

    HRA:20-88,HRB:20-100,HRC:20-70,HRD:40-77,HRE:70-100,

    HRF:60-100,HRG:30-94,HRH:80-100,HRK:40-100

    Testing Force Application ModeManual operation
    Indenter specification

    Diamond cone Rockwell indenter,Φ1.5875mm

    steel ball indenter

    DisplayMechanical dial
    Indication error0.1HR
    Indicator scale0~100(C),30~130(B)
    Rockwell scaleHRA,HRB,HRC,HRD,HRE,HRF,HRG,HRH,HRK
    Maximum height of specimen170mm
    Distance of Indenter to outer wall135mm
    Dimension510×212×700mm
    Main unit weight85kg

    Indication error

    ScaleStandard Hardness RangeAllowed Maximum Tolerance
    HRA20-75HRA±2HRA
    75-88HRA±1.5HRA
    HRB20-45HRB±4HRB
    45-80HRB±3HRB
    80-100HRB±2HRB
    HRC20-70HRC±1.5HRC
    HRD40-70HRD±2HRD
    70-77HRD±1.5HRD
    HRE70-90HRE±2.5HRE
    90-100HRE±2HRE
    HRF60-90HRF±3HRF
    90-100HRF±2HRF
    HRG30-50HRG±6HRG
    50-75HRG±4.5HRG
    75-94HRG±3HRG
    HRH80-100HRH±2HRH
    HRK40-60HRK±4HRK
    60-80HRK±3HRK
    80-100HRK±2HRK
    HRL100-120HRL±1.2HRL
    HRM85-110HRM±1.5HRM
    HRR114-125HRR±1.2HRR

    Working Principle

    The Rockwell hardness test is taking the diamond cone with 120°apex angle or the hardened steel ball with specified diameter as the indenter to press into sample surface with specific test force, then get the Rockwell hardness of the measured metallic materials according to the sample surface indentation depth.

    The Rockwell hardness measurement principle is shown as below figure. 0-0 is the position that the diamond indenter is not yet in contact with the sample. 1-1 figure is the indenter position under the affect of the preliminary test force, the indentation depth is h1. The preliminary test is to eliminate the influence to the testing result accuracy caused by the roughness of the sample surface. 2-2 in the figure is the indenter position under the influence of the testing force (the preliminary test force and the main test force). The depth is h2. 3-3 in the figure is the indenter position after dismounting the main test force. As the metal elasticity will recovery some degree after deformation, the really indentation depth of the indenter is h3. The plastic deformation caused by the main test force make the indenter pressing into the depth is h=h3-h1. Rockwell hardness value is determined by the size of h, the greater the depth h, the lower the hardness, otherwise, the higher the hardness.

    In the traditional concept, usually use a constant C minus h to represent the level of hardness, while the depth of indentation per 0.002mm as a unit of hardness. The hardness value obtained is called the Rockwell hardness value, denoted by the symbol HR.


    In the formula, c is a constant (for HRC, HRA, c is 0.2; for HRB, c is 0.26). The Rockwell hardness value HR obtained is an unknown number which is usually read directly on the test machine indicator when testing.

    Rockwell hardness tester working principle Figure


    It should be noted that the measured hardness values would be different with different indenter and test force. Therefore, the Rockwell hardness testing specifies 15 different hardness test scales according to the different indenter specification and test force sizes. And the HRB, HRC, HRA are the most widely used.


    Features

    • Widely used for high-precision hardness testing for parts with a variety of metal and non-metallic materials,
    • Using the classic design of mechanical and manual device, data reading intuitive and convenient, without external power supply, performance stable and reliable;
    • Option for various specifications of the indenter, support 15 types of Rockwell hardness scales testing.
    • With diamond indenter, durable and wear-resistance, the measurement is accurate. accurate measurement;
    • Consistent with GB/T230.1, GB/T230.2, JJG112, GB/T230.2, ISO 6508-2, ASTM, E18 and other related domestic and foreign standards.

    Scale

    ScaleIndenter type

    preliminary testing force

    (N)

    Testing force (N)Measuring RangeApplication
    A

    Diamond

    cone

    98.07(N)588.4(N)20-88HRAhard alloy, carbide, surface quenched steel, carburizing steel
    D980.7(N)40-77HRDthin steel sheet, surface quenched steel
    C1471(N)20-70HRCquenched steel, tempered steel, chilled cast iron
    F

    Φ1.5875

    1/16 inch steel ball


    588.4(N)60-100HRFcast iron, aluminum, magnesium alloy, bearing alloy
    B980.7(N)20-100HRBmild steel, copper alloy, annealed steel
    G1471(N)30-94HRGphosphorus iron, beryllium bronze, malleable cast iron
    H

    Φ3.175

    1/8inch steel ball


    588.4(N)80-100HRHaluminum, zinc, lead etc.
    E980.7(N)70-100HREbearing alloy, tin, hard plastics and other soft materials
    K1471(N)40-100HRK
    L

    Φ6.35

    1/4 inch steel ball

    588.4(N)50-115HRLHard plastic ,hard rubber, aluminum, tin, bronze, mild steel, synthetic resin, friction materials and etc.
    M980.7(N)50-115HRL
    R

    Φ12.7

    1/2 inch steel ball

    588.4(N)50-115HRL

    Applications

    • Used for quality control in metal processing manufacturing
    • Used for failure analysis testing of metallic materials;
    • Demonstration experiment for education and teaching in Colleges and Universities;
    • Hardness testing of materials in scientific research institutions

    Working Conditions

    • Operation Temperature:10~30℃;
    • Relative Humidity:≤65%;
    • The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust.

    Configurations

    NO.NameQTY.Remarks

    Standard Configuration

    1Main unit1
    2Diamond Rockwell indenter1
    3

    Φ1.5875mm

    1/16in steel ball indenter

    1
    4Counterweights3
    5Small Testing Table1Dia 60mm
    6Large Testing Table1Dia 150mm
    7V-shape Testing Table1Test cylindrical specimens
    8

    Rockwell Standard Block

    HRB

    1
    9

    Rockwell Standard Block

    HRC

    2High value and low value
    10Big screw driver1
    11Small screw driver1
    12Plastic Dust Cover1
    13Attached files1
    14ABS instrument case1
    Optional Configuration1

    Φ3.175mm

    1/8inch steel ball indenter

    1Mainly use to testing Rockwell hardness for non-ferrous materials like hard plastic and so on.
    2

    Φ6.35mm

    1/4inch steel ball indenter

    1
    3

    Φ12.7mm

    1/2inch steel steel ball indenter

    1

    Maintenance and care

    • During testing, to ensure accuracy, please make sure the distance between the adjacent indentation center and the distance from the indentation center to edge of the specimen is greater than 3mm.
    • Normally, the first point is only used to offset the gap of each support surface without needing to record the test result. Record the statistical test result from the second point.
    • Screw protective cover is designed to protect the screw from dust invasion. When instrument idle or test specimen height less than 100 mm, it should be set on the outside of the screw. For testing the specimen with height above 100mm, it should be taken out for normal use.
    • It is strictly prohibited to turn the variable loading handwheel when the instrument load or unload the test force. Rotating the handwheel forcibly will cause the internal gear dislocation, test force in chaos and even damage the internal parts of the instrument
    • If the specimen has visible deformation marks on the back and edges, the test result would be useless. It should choose the intender or test force to test again.
    • The test personnel shall strictly observe the operating procedures. Please use the standard blocks often to calibrate the instrument before and after testing.
    • Pay attention to palm the instrument for carrying to forbid falling across. Please fix well the measuring lever, counterweight and boom before carrying.
    • When not in use for a long time, please cover the dust cover to prevent dust into the instrument interior. And the hardness block, indenter should be coated with antirust oil to prevent rusting after using.
    • Please regularly put a small amount of oil on the screw and the handwheel interface
    • The hardness tester should be calibrated at least once a year to ensure its accuracy
    • Don’t disassemble the instrument without authorization, for maintenance related matters, please contact MITECH after-sale service department with 4000600280
    Quality Mitech MHR-150A High accuracy Durable High quality and inexpensive Manual Rockwell Hardness Tester for sale
    Send your message to this supplier
     
    *From:
    *To: Mitech CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 bjjsgy.com. All rights reserved.