Skymen 1200W Submersible Ultrasonic Generator SUS304 With Sweep Mode
Skymen 1200W Ultrasonic Generator With Sweep Mode Submersible Transducer Box
Ultrasonic technology extraction is beyond any previous technical feasibility, access to efficient extraction, more effective than heat extraction resident agency regulations, and shortens the extraction time, most of the material before the process is to be extracted within 10min.
Packing & delivery details:
|
Packing , loading, delivery time |
|
|
Packing unit |
1set/wooden case |
|
Packing method |
Export wooden case |
|
Loading port |
Shenzhen |
|
Delivery time |
About 15 working days |
|
Minimum Order Quantity |
1set |
|
Transport method |
By express company / air / sea |
Transducer pack Specifications:
|
Model (JTM models) |
JTM-1006 |
JTM-1012 |
JTM-1018 |
JTM-1024 |
JTM-1030 |
JTM-1036 |
|||
|
Ultrasonic transducer box size (mm) |
L |
305 |
355 |
406 |
500 |
550 |
500 |
||
|
W |
250 |
305 |
305 |
355 |
406 |
460 |
|||
|
H |
100 |
100 |
100 |
100 |
100 |
100 |
|||
|
Housing material |
SUS304/SUS316L |
||||||||
|
Surface finishing |
Hard-Cr plating treatment (20+microns) |
||||||||
|
Ultrasonic frequency |
28KHz / 40KHz |
||||||||
|
Ultrasonic transducers |
6pcs |
12pcs |
18pcs |
24pcs |
30pcs |
36pcs |
|||
|
Ultrasonic power |
300W |
600W |
900W |
1200W |
1500W |
1800W |
|||
|
Electronic generator |
KG300 |
KG600 |
KG900 |
KG1200 |
KG1500 |
KG1800 |
|||
|
Ultrasonic generator work separately control transducers |
|||||||||
|
power suppy |
AC 110V/220V or 220/240V, 1,13AMP |
||||||||
|
*Custom made:68KHz/80KHz/120KHz and size are all available |
|||||||||
Features:
Original BLT type transducer
SUS stainless steel housing Hard-Cr plating Treatment ( 20 + microns )
Adaptable for continuous operation
Adjustable ultrasonic power
With separate control ultrasonic electronic generator
Custom made size is available
Transducer no./transducer box: range[6pcs~40pcs per box]
Ultrasonic power: range[300W~2000W]
Ultrasonic frequency: 28KHZ/40KHz
underwater ultrasonic transducer generator Features:
Original BLT type transducer
SUS stainless steel housing Hard-Cr plating Treatment ( 20 + microns )
Adaptable for continuous operation
ultrasonic generator with sweep mode
User-friendly operation
Transducer no./transducer box: range[6pcs~36pcs per box]—transducer box size can be custom made
Ultrasonic power: range[300W~1800W]
Ultrasonic frequency: 28KHZ/40KHz
Cleaning feature
1.Submersible Transducers are manufactured to meet individual customer specifications, ensuring the size and ultrasonic power are tailored to provide the cleaning and processing results.
2.These submersible transducers provide excellent ultrasonic activity and are easily controlled through Ultrawave's technologically advanced
Convenience Install
Submersible Transducers can be easily installed or retro-fitted to an existing tank, allowing easy service and maintenance whilst having the benefits of an upgraded system with ultrasonic cleaning technology.
ultrasonic transducer generator hose tube
How to Use an Ultrasonic Cleaner for Medical & Surgical Instruments
Medical and surgical instruments in a variety of sizes and complexity can pose challenges when it comes to cleaning, disinfecting and sterilizing them after use. An ultrasonic cleaner is an ideal tool for the first step in this three step process to protect medical personnel and patients from possible infection due to pathogens that remain on the instruments after a procedure.
Suggested Ultrasonic Cleaning Procedure
In all cases manufacturers’ instructions should be followed when using an ultrasonic cleaning process. These are representative steps.
Fill the ultrasonic cleaning tank with an approved medical instrument cleaning solution such as CLN-LR012 available from Tovatech following dilution instructions provided. Turn the cleaner on to start the degassing process. This step removes entrained air in new solutions that interferes with the efficiency of cavitation and takes approximately 10 minutes.
In the meantime:
- Segregate instruments by alloy or composition to avoid potential damage (Chromium plated instruments should not be cleaned ultrasonically)
- Instruments with movable parts should be disassembled to facilitate cleaning
- Place the instruments the ultrasonic cleaner’s mesh basket, taking care that they do not come in contact with each other
- Cannulated or lumened instruments should be positioned to insure interiors are wetted with the cleaning solution. In some instances placing them on an angle will facilitate this
- Set the control panel per manufacturers’ instructions and start the cleaning process
At the end of the cycle, remove the instruments from the ultrasonic cleaning bath and thoroughly rinse them to remove all traces of the cleaning solution. Deionized water rinses will avoid spotting. If the instruments are not to be immediately disinfected and sterilized be certain that they are thoroughly dried and protected. Part reassembly can occur after sterilization.
Procedures should be in place to guide the replacement of used ultrasonic cleaning solutions. In some instances it is recommended that solution be drained and tanks thoroughly cleaned and dried after each ultrasonic cleaning cycle. many solutions available today are biodegradable, which facilitates disposal but local authorities should be consulted on proper practices.
The ultrasonic cleaner uses ultrasonic waves (vibration) using water with detergents or enzymatic products to break up soil and organic material on medical instruments/devices. These devices are rinsed then autoclaved (sterilized). The autoclave sterilizer uses heat, steam, and pressure to kill all pathogenic microorganisms and their spores.
Package Includes:
1 x Ultrasonic Transducers Plate
1 x Generator
1 x Manual
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.