WQP high efficiency 100m3/h stainless steel submersible sewage pump
WQP high efficiency 100m3/h stainless steel submersible sewage pump
100m3/h stainless steel submersible sewage pump Product Overview
The WQP Stainless Steel Submersible Sewage Pump is specifically designed for handling wastewater containing solid particles and fibrous materials. Made from high-quality stainless steel, it boasts strong corrosion resistance and a long service life. This pump is suitable not only for residential wastewater discharge but also finds wide application in municipal projects, construction sites, mining, and other scenarios requiring sewage treatment.
100m3/h stainless steel submersible sewage pump Product Main Features
- High Efficiency & Energy Saving: With an optimized hydraulic model design, this pump offers higher efficiency, ensuring powerful suction capabilities while achieving energy savings and emission reductions.
- Robust and Durable: The selection of superior stainless steel material effectively resists corrosion, ensuring stable operation over a long period.
- Easy Maintenance: Featuring a compact and rational structure, it simplifies disassembly and maintenance, significantly reducing users' post-maintenance costs.
- Safety and Reliability: Equipped with multiple protection devices such as overheating protection and leakage protection, ensuring safety during use.
Structure Description of WQP Stainless Steel Submersible Sewage Pump
The WQP series stainless steel submersible sewage pumps consist of two parts: the motor and the pump, separated by an oil isolation chamber and mechanical seal components, making them electromechanical integrated products. The motor and pump share the same shaft (rotor), resulting in a shorter overall pump length and a compact structure. It comes with various protective devices to ensure reliable pump operation. The main components function as follows:
- Signal Line: Comes with a full-protection water pump control cabinet, providing comprehensive protection to the pump against water leakage, phase failure, short circuit, overheating, motor overload, etc.
- Motor Stator: Uses B or F class insulation.
- Leakage Sensor: Installed in the oil chamber, it can send signals to the control system to protect the pump when water enters due to damaged mechanical seals.
- Mechanical Seal: Employs dual-seal series connection made of new hard-wearing and corrosion-resistant tungsten carbide material, featuring reliable sealing, wear resistance, and a long lifespan.
- Impeller: Designed with single or double channel structures, it has strong passing capacity, capable of passing large materials and fibrous waste, reducing blockages and entanglement issues.
- Pump Body: Used in conjunction with the impeller to achieve high efficiency of the pump.
- Sealing Ring: Located at the mouth ring of the pump body, it can be replaced when wear occurs to ensure the pump operates at optimal efficiency.
WQP Stainless Steel Submersible Sewage Pump Parameters:
| Model | Outlet diameter (mm) | Flow (m3/h) | Head (m) | Power (kw) | Speed (r/min) |
| WQP50-18-30-3 | 50 | 18 | 30 | 3 | 2900 |
| WQP50-40-15-4 | 50 | 40 | 15 | 4 | 2900 |
| WQP50-25-32-5.5 | 50 | 25 | 32 | 5.5 | 2900 |
| WQP50-20-40-7.5 | 50 | 20 | 40 | 7.5 | 2900 |
| WQP65-25-15-2.2 | 65 | 25 | 15 | 2.2 | 2900 |
| WQP65-25-30-4 | 65 | 25 | 30 | 4 | 2900 |
| WQP65-30-40-7.5 | 65 | 30 | 40 | 7.5 | 2900 |
| WQP65-35-50-11 | 65 | 35 | 50 | 11 | 2900 |
| WQP65-35-60-15 | 65 | 35 | 60 | 15 | 2900 |
| WQP80-43-13-3 | 80 | 43 | 13 | 3 | 2900 |
| WQP80-40-15-4 | 80 | 40 | 15 | 4 | 2900 |
| WQP80-65-25-7.5 | 80 | 65 | 25 | 7.5 | 2900 |
| WQP100-110-10-5.5 | 100 | 110 | 10 | 5.5 | 1450 |
| WQP100-100-15-7.5 | 100 | 100 | 15 | 7.5 | 1450 |
| WQP100-80-20-7.5 | 100 | 80 | 20 | 7.5 | 1450 |
| WQP100-100-25-11 | 100 | 100 | 25 | 11 | 1450 |
| WQP100-100-30-15 | 100 | 100 | 30 | 15 | 1450 |
| WQP125-130-15-11 | 125 | 130 | 15 | 11 | 1450 |
| WQP125-130-20-15 | 125 | 130 | 20 | 15 | 1450 |
| WQP150-150-13-11 | 150 | 150 | 13 | 11 | 1450 |
| WQP150-180-15-15 | 150 | 180 | 15 | 15 | 1450 |
| WQP150-180-20-18.5 | 150 | 180 | 20 | 18.5 | 1450 |
| WQP150-180-25-22 | 150 | 180 | 25 | 22 | 1450 |
| WQP150-180-30-30 | 150 | 180 | 30 | 30 | 1450 |
| WQP150-130-30-22 | 150 | 130 | 30 | 22 | 1450 |
| WQP150-200-30-37 | 150 | 200 | 30 | 37 | 1450 |
| WQP150-200-50-55 | 150 | 200 | 50 | 55 | 1450 |
| WQP200-300-7-11 | 200 | 300 | 7 | 11 | 1450 |
| WQP200-250-11-15 | 200 | 250 | 11 | 15 | 1450 |
| WQP200-250-15-18.5 | 200 | 250 | 15 | 18.5 | 1450 |
| WQP200-400-10-22 | 200 | 400 | 10 | 22 | 1450 |
| WQP200-400-13-30 | 200 | 400 | 13 | 30 | 1450 |
| WQP200-400-30-45 | 200 | 400 | 30 | 45 | 1450 |
| WQP200-400-32-55 | 200 | 400 | 32 | 55 | 1450 |
| WQP200-400-45-75 | 200 | 400 | 45 | 75 | 1450 |
| WQP200-400-50-90 | 200 | 400 | 50 | 90 | 1450 |
| WQP200-300-65-110 | 200 | 300 | 65 | 110 | 1450 |
| WQP200-300-15-22 | 200 | 300 | 15 | 22 | 1450 |
| WQP200-250-22-30 | 200 | 250 | 22 | 30 | 1450 |
| WQP200-350-25-37 | 200 | 350 | 25 | 37 | 1450 |
| WQP250-500-7-22 | 250 | 500 | 7 | 22 | 1450 |
| WQP250-600-9-30 | 250 | 600 | 9 | 30 | 1450 |
| WQP250-600-9-37 | 250 | 600 | 9 | 37 | 1450 |
| WQP250-600-15-45 | 250 | 600 | 15 | 45 | 1450 |
| WQP250-600-20-55 | 250 | 600 | 20 | 55 | 1450 |
| WQP250-600-25-75 | 250 | 600 | 25 | 75 | 1450 |
| WQP300-800-12-45 | 300 | 800 | 12 | 45 | 1450 |
| WQP300-800-15-55 | 300 | 800 | 15 | 55 | 1450 |
| WQP300-800-20-75 | 300 | 800 | 20 | 75 | 1450 |
| WQP300-100-25-110 | 300 | 1000 | 25 | 110 | 1450 |
| WQP350-1100-10-55 | 350 | 1100 | 10 | 55 | 1450 |
| WQP350-1000-15-75 | 350 | 1000 | 15 | 75 | 1450 |
| WQP400-1500-8-55 | 400 | 1500 | 8 | 55 | 980 |
| WQP400-1300-13-75 | 400 | 1300 | 13 | 75 | 1450 |
| WQP400-1500-10-75 | 400 | 1500 | 10 | 75 | 980 |
| WQP400-1500-18-110 | 400 | 1500 | 18 | 110 | 1450 |
Stainless Steel Submersible Sewage Pump Fault analysis and troubleshooting
|
Fault Phenomenon |
Analysis of Causes |
Exclusion Method |
|
Traffic is insufficient
Or no water comes out |
1. The impeller rotates incorrectly 2. Whether the valve is open and in good condition 3. The pipeline is blocked 4. Too low speed 5. Too high head 6. The density of the pumped medium is large 7. High medium viscosity 8. Seal ring damage (at the mouth ring) |
1. Adjust the rotation direction of impeller 2. Check, maintain and eliminate 3. Clear up debris 4. Check electrical equipment and circuits 5. Change the pump or reduce the head 6. Dilute with water to reduce concentration 7. Reduce viscosity 8. Replacement |
|
fluctuation of service |
1. Imbalance of impeller 2. Bearing damage |
1. Send to the manufacturer for replacement or correction 2. Replace the impeller |
|
The pump cannot be started |
1. Deficiency 2. The impeller is stuck 3. Circuit, joint or cable open circuit 4. Stator winding is burnt out 5. Electrical control is faulty |
1. Check the circuit for repair 2. Remove debris 3. Test and repair with an ohmmeter 4. Repair and replace the winding 5. Repair or replace |
|
The current is too high |
1. Low working voltage 2. Blockage of pipeline and impeller 3. The liquid to be pumped is too thick or viscous 4. Too high lift |
1. Adjust the working voltage 2. Clean the pipeline and replace the winding 3. Change density or viscosity 4. Reduce traffic and increase traffic |
|
Low insulation resistance |
1. Leakage of cable power terminal 2. Cable damage 3. Leakage caused by mechanical seal wear 4. All O-rings fail 5. The shell is corroded by the medium and leaks water |
1. Tighten the compression nut 2. Replacement 3. Replacement 4. Replacement 5. Repair |
Should you have any questions, feel free to contact us. We have professional sales and technical teams ready to provide you with specialized solutions. Contact us via email at enquiry02@apkpump.com or WhatsApp at +86 17537187726.