IFM Flow monitor SI5000 SID10ABBFPKG/US-100 in stock
Price:
USD
MOQ:
1PC
Delivery Time:
4-6weeks
Brand:
IFM
Product Description
IFM Flow monitor SI5000 SID10ABBFPKG/US-100 in stock
- Reliable monitoring of liquids and gases in pipes
- Variable process connection using adapters
- Easy setting of the switch points for quick set-up
- Robust stainless steel housing for use in harsh industrial environments
- LED bar graph for indication of switch point and flow
-
Product characteristics
Number of inputs and outputs Number of analogue outputs: 1 Measuring range -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O -1.25...25 kPa Process connection threaded connection Aseptoflex external thread Aseptoflex Application
Special feature Gold-plated contacts Application flush mountable for the food and beverage industry Media viscous media and liquids with suspended particles; liquids and gases Medium temperature[°C] -25...125; (145 max. 1h) Min. bursting pressure 30000 mbar 12000 inH2O 3000 kPa Pressure rating 6000 mbar 2400 inH2O 600 kPa Type of pressure relative pressure No dead space yes Electrical data
Operating voltage[V] 14...30 DC Min. insulation resistance[MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Measuring principle hydrostatic Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1 Outputs
Total number of outputs 1 Output signal analogue signal Number of analogue outputs 1 Analogue current output[mA] 4...20 Max. load[Ω] 550; (Ub = 24 V; (Ub - 13 V) / 20 mA) Overload protection yes Measuring/setting range
Measuring range -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O -1.25...25 kPa Analogue start point -12.5...100 mbar -5...40.2 inH2O -1.25...10 kPa Analogue end point 50...250 mbar 20.2...100.4 inH2O 5...25 kPa In steps of 0.5 mbar 0.2 inH2O 0.05 kPa Factory setting ASP = 0.0 mbar AEP = 250.0 mbar Accuracy / deviations
Repeatability[% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) Characteristics deviation[% of the span] < ± 0,6; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) Linearity deviation[% of the span] < ± 0,5; (Turn down 1:1) Hysteresis deviation[% of the span] < ± 0,1; (Turn down 1:1) Long-term stability[% of the span] < ± 0,1; (Turn down 1:1; per year) Temperature coefficient zero point[% of the span / 10 K] < ± 0,1; (0...80 °C) Temperature coefficient span[% of the span / 10 K] < ± 0,4; (0...80 °C) Response times
Max. response time analogue output[ms] 3 Software / programming
Parameter setting options zero point; span Interfaces
Communication interface EPS Operating conditions
Ambient temperature[°C] -25...80 Storage temperature[°C] -40...100 Protection IP 67
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1 |
| Process connection | threaded connection M18 x 1,5 internal thread |
Application
| Media | Liquids; Gases | ||
| Medium temperature[°C] | -25...80 | ||
| Pressure rating |
|
| Liquids | |
|---|---|
| Medium temperature[°C] | -25...80 |
| Gases | |
|---|---|
| Medium temperature[°C] | -25...80 |
Electrical data
| Operating voltage[V] | 19...36 DC |
| Current consumption[mA] | < 60 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] | 10 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1 |
Outputs
| Total number of outputs | 1 |
| Output signal | switching signal |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] | 2.5 |
| Permanent current rating of switching output DC[mA] | 250 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Probe length L[mm] | 45 |
| Liquids | |
|---|---|
| Setting range[cm/s] | 3...300 |
| Greatest sensitivity[cm/s] | 3...100 |
| Gases | |
|---|---|
| Setting range[cm/s] | 200...3000 |
| Greatest sensitivity[cm/s] | 200...800 |
Accuracy / deviations
| Repeatability[cm/s] | 1...5 | ||
| Note on repeatability |
|
||
| Temperature drift[cm/s x 1/K] | 0.1; (for water 5...100 cm/s; 10...70 °C) | ||
| Temperature gradient[K/min] | 300 | ||
| Switch point accuracy[cm/s] | ± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting) | ||
| Hysteresis[cm/s] | 2...5; (for water 5...100 cm/s; 25 °C; Factory setting) |
Response times
| Response time[s] | 1...10 |
| Liquids | |
|---|---|
| Response time[s] | 1...10 |
| Gases | |
|---|---|
| Response time[s] | 1...10 |
Software / programming
| Adjustment of the switch point | pushbutton |
Operating conditions
| Ambient temperature[°C] | -25...80 |
| Storage temperature[°C] | -25...100 |
| Protection | IP 67 |
We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
-
•It will take 3 to 7days to reach in your hands.China Post delivery schedule will be in 20-45 days. If you can't wait, please choose other express.
Our Advantage:
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
GREAT SYSTEM INDUSTRY CO. LTD
Location
10A, SEAVIEW PLAZA, TAIZI ROAD, NANSHAN DISTRICT, SHENZHEN, CHINA
Contact Person
Roc