High And Low Temperature And Humidity Chamber 150L IEC60068-2-78
High and Low Temperature and Humidity Chamber 150L IEC60068-2-78
Complied Standards & Clauses
IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”
IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”
IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”
IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”
Equipment Overview
The purpose is to confirm the product's reliability of storage and transportation under high and low temperature alternating heat and humidity. This test chamber is used for cold, heat, humidity and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc.
Technical Parameters
| Technical Parameters | ||
| Control & Operation | PLC and touch screen intelligent control system | |
Chamber Size | Inner Size | External Size |
| 500*600*500 mm | 780*1650*1550 mm | |
| Temperature Range | -70 °C ~+150°C | |
| Humidity Range | 20%~98%RH | |
| Temperature fluctuation | ±0.5℃ | |
| Humidity fluctuation | ≤2.5% | |
| Temperature deviation | ≤±2.0℃ | |
| Humidity Deviation | ≤±3% | |
| Heating Rate | ≧2-3°C/min | |
| Cooling Rate | ≧1°C/min, average no load | |
| c) Controller specifications | Technical indicators: |
| Controller technical parameters | Accuracy: temperature ±0.1℃+1digit, humidity ±1%R.H+1digit |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.

