ShenzhenYijiajie Electronic Co., Ltd.
                                                                                                           
Verified Supplier
20 Years
Since 2006
Menu

MOX20 MOX-20 AAE29-210 Gas Oxygen Sensor Use Anesthesia Machines Oxygen Concentrators

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 3-5work days
Product Description

   

                                                         MOX-20 Gas oxygen sensor

 

Basic Parameters:

  1. Measurement Range: 0%–100% O₂
  2. Output Signal: 13–16 mV in air
  3. Circuit Interface: 3-pin (Molex)
  4. Accuracy & Repeatability: <1% O₂ by volume (after calibration in 100% O₂)
  5. Linearity Error: <3% relative error
  6. Response Time (T90): <12 seconds (to 90% of final value)
  7. Zero Drift: <200 μV after 5 minutes in 100% NH₃
  8. Temperature Influence: -0.03%/°C relative to 25°C
  9. Pressure Influence: Proportional to O₂ partial pressure
  10. Mechanical Shock Resistance: <1% relative error after 1m drop
  11. Operating Temperature: 0°C–50°C
  12. Temperature Compensation:
    • Built-in thermistor compensation
    • ±3% relative error at 25°C–40°C
    • ±8% relative error (steady-state) at 0°C–50°C
  13. Operating Humidity: 0%–99% RH (tolerates condensation for hours)
  14. Storage Temperature: -20°C–50°C (recommended: 5°C–15°C)
  15. Recommended Load Resistance: ≥10 Ω
  16. Warm-up Time: <30 minutes after sensor replacement
  17. Rated Service Life: ≥1,000,000% O₂·h (volume-oxygen hours)
  18. Weight: ~28 g

 

Applications:

The MOX-20 oxygen sensor is primarily used in medical devices such as:

 

  • Ventilators
  • Anesthesia machines
  • Oxygen concentrators
  • Oxygen analyzers for measuring O₂ concentration in respiratory gas mixtures.

 

Manufacturer:

 

 

For detailed technical specifications and application notes, please refer to the official datasheet.

 

Parameter

Value

Model MOX-20
Sensor Type Electrochemical oxygen sensor
Measurement Range 0%–100% O₂ (by volume)
Output Signal in Air 13–16 mV
Interface 3-pin Molex connector
Accuracy <1% O₂ (after calibration in 100% O₂)
Linearity Error <3% relative error across full range
Response Time (T90) <12 seconds (to 90% of final value)
Zero Drift in NH₃ <200 μV after 5 min in 100% NH₃
Temperature Coefficient -0.03%/°C (relative to 25°C)
Pressure Dependence Proportional to O₂ partial pressure
Shock Resistance <1% error after 1m drop test
Operating Temperature 0°C–50°C
Storage Temperature -20°C–50°C (recommended: 5°C–15°C)
Humidity Range 0%–99% RH (non-condensing, tolerates short-term condensation)
Temperature Compensation Built-in thermistor; ±3% error at 25°C–40°C, ±8% at 0°C–50°C
Recommended Load Resistance ≥10 Ω
Warm-up Time <30 minutes after installation
Service Life ≥1,000,000% O₂·h (volume-oxygen hours)
Weight ~28 g

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ShenzhenYijiajie Electronic Co., Ltd.
Location Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Contact Person Xu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.