GS+7H2S Hydrogen Sulfide (H2S) Sensor For Industrial Safety Industrial General
GS+7H2S Hydrogen Sulfide (H2S) Sensor For Industrial Safety Industrial General
Working Principle:
The GS+7H2S sensor operates based on the electrochemical three - electrode principle. Hydrogen sulfide gas diffuses through a permeable membrane and reacts with chemicals at the working electrode, while oxygen reacts at the counter - electrode. These reactions release charges to form a current, and the magnitude of the current is proportional to the hydrogen sulfide concentration. By measuring the current, the concentration of hydrogen sulfide can be determined.
Key Features:
- High stability, ensuring accurate and reliable measurement results over an extended period.
- Fast response and recovery, enabling quick detection of hydrogen sulfide and a rapid return to the baseline after the gas is removed.
- Robust environmental stability, allowing it to function properly in a variety of environmental conditions, including different temperatures and humidity levels.
Common Applications:
- Industrial Safety: Used to detect hydrogen sulfide in industrial production processes to safeguard the safety of workers and equipment.
- Industrial General: Such as in petrochemical plants, refineries, and other industrial sites to monitor hydrogen sulfide emissions and ensure compliance with environmental regulations.
|
Parameter |
Value (GS+7H2S) |
Value (GS+7H2S - HC) |
|---|---|---|
| Measurement Range | 0 - 200 ppm | 0 - 5000 ppm |
| Maximum Overload | 1000 ppm | 1000 ppm |
| Output Signal | 370 ± 100 nA/ppm | 40 ± 20 nA/ppm |
| Response Time (T90) | < 40 seconds | < 40 seconds |
| Resolution | < 0.2 ppm (typical, dependent on electronics) | < 0.2 ppm (typical, dependent on electronics) |
| Recommended Load Resistor | 10 ohms | 10 ohms |
| Bias Voltage | 0V | 0V |
| Repeatability | < ± 1% H2S equivalent | < ± 1% H2S equivalent |
| Temperature Range | -40 °C to +50 °C | -40 °C to +50 °C |
| Pressure Range | Atmospheric ± 10% | Atmospheric ± 10% |
| Expected Operation Life | > 24 months | > 24 months |
| Warranty | 2 years from the date of dispatch | 2 years from the date of dispatch |
| Typical Baseline Range (Pure Air) | < ± 1 ppm H2S equivalent | < ± 1 ppm H2S equivalent |
| Long - term Output Drift | < 20% per annum | < 20% per annum |
Get in Touch