ODM SP600 3 Phase Power Inverter AC Motor For Squirrel Cages
KD600S General Purpose AC Drive
1.5KW 2.2KW 4KW 5.5KW VFD Variable Frequency Drive 3phase With LCD Keyboard
Product features
-
KD600S series VFD with advanced functions, such as high performance vector control,user-programmable function and backstage monitoring software, variable communication and supportingmultiple PG cards and so on. It is applicable to tension control, textile, papermaking, machine tools, wire drawing fans andpumps, packaging, food and all kinds of automatic production equipment.
-
-
Its excellent performance is equivalent and competitive to most of international brand AC drives, we have model range from 0.75KW-710KW, also we support OEM and ODM.
| Model | Power Rating | Input Voltage | Output FREQ | Type |
|---|---|---|---|---|
| KD600S Series | 0.4kW-400kW | 208-240V / 380-480V ±10% | 0.00-3200.00Hz | DC/AC to AC inverters |

Advantages
Thanks to sophisticated engineers, scientific producing workmanship, rigorous quality control systems and management team, K-Drive frequency inverters are equipped with advanced features, some of which are listed as below:
01. Starting torque: 180% at 0.5Hz (V/f pattern, SVC pattern);
02. Speed adjustable range: 1: 100 (V/f pattern, SVC pattern);
03. Speed accuracy: +/-0.5% (V/f pattern), +/-0.2% (SVC pattern);
04. Over load capability: 150% 1minute, 180% 10seconds;
05. Abundant frequency command sources;
06. Diverse input and output terminals;
07. Ambient temperature: -10°C~50°C;
08. High precise torque constraint, process PID control, multi-speed control, contracting brake control, field weakening control, all sides protection, etc;
09. Online and offline auto-tuning of motor parameters can both performed;
10. Extremely short-time acceleration can be performed without any trip, such as 0.1s or 0s from 0Hz to 50Hz;
| Mains Supply (L1/L,L2,L3/N) | |
|---|---|
| Supply voltage | 208-240V ±10% 380-480V 690V ±10% |
| Power source frequency | 50/60Hz ± 5% |
| Displacement power factor (cos φ) | (>0.98) |
| Output Data (U, V, W) | |
|---|---|
| Output voltage / frequency | 0-100% of supply voltage / 0.00-600.00Hz or customized |
| Ramp time | 0.01-60000s |
Note: 150% current can be provided for 1 minute, 180% for 10 seconds. Higher overload rating is achieved by oversizing the drive.
| Digital Input | |
|---|---|
| Programmable digital inputs | 5 |
| Logic | NPN or PNP |
| Voltage level | 22 - 26V |
| Analog Input | |
| Analog inputs | 2 |
| Modes | Voltage or current |
| Level | 0 to +10V, 0/4 to 20 mA (scalable) |
| Automatic correction | YES |
| Relay Output | |
| Programmable relay outputs | 1 |
| RA - RB / TA - TB | Normally close |
| RA - RC / TA - TC | Normally open |
| Contact capacitance | 250 V AC / 3A, 30 V DC / 3 A |
| Terminal 485 Interface | |
| 485+ / 485- | Rate: 4800/9600/19200/38400/57600/115200 bps Max. distance: 500 m |
| GND | Isolated from COM |
| Ambient | |
| Vibration | Less than 5.9 m/s² (0.6g) |
| Humidity | Relative humidity 5% - 95 %. No condensation |
| Corrosive environment | 3C3 |
| Ambient temperature | -10 ºC - 50 ºC |
| Altitude | 0 - 2,000 m |
| Rated output current derated 1% every 100 m above 1,000 m | |
| Storage temperature | -40 - +70 ºC |
| Efficiency | Efficiency At rated amps: ≥93% |
| IP grade | IP20 |
| Cooling method | Forced air cooling |
| Fieldbus Communication | |
| Modbus RTU, Modbus ASCII | Built-in |
Applications
KD600S drives are economical series at K-Drive. They offer V/f control, including voltage and frequency separated control, adaptable to various industrial applications if sensor-less vector control is not required, including printing machines, packaging machines, pumps, fans and blowers, etc.


Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.