Online Monitoring CEMS Solutions Ammonia Slip NH3 Laser Gas Analyzer
Price:
USD5000-10000
MOQ:
1 Unit
Delivery Time:
10-15 working days
Brand:
JUGE
Product Description
CEMS Ammonia Slip Online Monitoring System NH3 Laser Gas Analyzer
>>Overview
This system is primarily used for denitrification process control in various industrial sectors, such as coal-fired power plants, aluminum plants, steel mills, smelters, waste-to-energy plants, cement plants, chemical plants, glass factories, and more.
>>Feature
1) Self-diagnosis and alarm function.
2) Laser absorption spectroscopy with minimal background interference and fast response.
3) High detection sensitivity and low resolution.
4) Built-in long optical path design to solve interference issues.
5) Low system maintenance cost and minimal maintenance.
6) High structural stability, adaptable to various environments.
>>Main technical parameters
The system is based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology, utilizing the characteristic absorption of specific laser wavelengths by gas molecules. It analyzes the change in laser absorption intensity to determine the gas concentration.
>>Feature
1) Self-diagnosis and alarm function.
2) Laser absorption spectroscopy with minimal background interference and fast response.
3) High detection sensitivity and low resolution.
4) Built-in long optical path design to solve interference issues.
5) Low system maintenance cost and minimal maintenance.
6) High structural stability, adaptable to various environments.
>>Main technical parameters
| Working condition | Power supply | 220vac,<3kw |
| Sweeping gas | (0.4~0.6) MPA compressed air | |
| Ambient temperature | -20ºC~55ºC | |
| Performance index | Light path length | 760mm |
| Range | 0~100 (ppm or mg/m3) (range-adjustable) | |
| T90 response time | <300 seconds | |
| Reading error | ≤ ± 5% (nominal value) | |
| Repeatability | ≤ ±2% F.S | |
| Drift | ≤ ±2.5% F.S | |
| Protection level | Ip55 | |
| Preheating time | 120min | |
| Functional parameter | Digital output | RS485 |
| Analog output | 4 -20 ma maximum load of 500Ω | |
| Switch output | Load capacity: Ac / DC 24V / l A; Backback signal, low instrument wind pressure, abnormal temperature alarm, etc. (customizable) |
|
| Sample gas temperature | <600ºC | |
| Other parameters | Sample gas pressure | Atmospheric pressure of ± 5 KPA |
| Sampling traffic | 2-3l/min | |
| Ambient temperature | -10~55ºC | |
| Ambient pressure | 70~120kpa | |
| Outline dimension | (950h×1160l×325w)mm | |
| Weight | 120kg |
>>System composition
| No. | Name | Model and specification | Quantity | Unit |
| 1 | Pre-processing cabinet | Pre-treatment and control devices | 1 | Set |
| 1.1 | Analysis Cabinet | 950H×1160L×325W mm | 1 | Set |
| 1.2 | Electromagnetic valve | DC24v, normally closed | 2 | Set |
| 1.3 | Injection pump | 8l/min | 1 | Set |
| 1.4 | High-temperature precision filter | 0.2um | 1 | Set |
| 1.5 | Control circuit | Including automatic sampling, back-blowing, and temperature control | 1 | Set |
| 1.6 | High temperature cut-off valve | BTB-DN10, with a pneumatic valve | 1 | Set |
| 2 | Analytic system | NH3 analyzer | 1 | Set |
| 3 | Heated-type sampling probe | AG-TT07 | 1 | Set |
| 4 | Sampling heat tracing pipeline | 60w/m | 3 | Set |
| 5 | Spare part | See the list of spare parts | 1 | Set |
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Nanjing Juge Environmental Technology Co., Ltd.
Location
Building 17, No. 99 Guangli Road, Moling Subdistrict, Jiangning District, Nanjing, Jiangsu
Contact Person
Leon Chen