| Sign In | Join Free | My bjjsgy.com | 
 | 
| Categories | Split Core Current Transformer | 
|---|---|
| Brand Name: | GFUVE | 
| Model Number: | LZCG530-10 | 
| Certification: | CE,ISO9001,UL | 
| Place of Origin: | BEIJING,CHINA | 
| MOQ: | 3 pcs | 
| Payment Terms: | T/T, Western Union, Paypal | 
| Supply Ability: | 1000+PC+per Month | 
| Packaging Details: | Standard wooden case | 
| Rated primary current: | 20-600A | 
| Rated load: | ≤25VA | 
| Rated frequency: | 50Hz or 60Hz | 
| Rated secondary current: | 5A or 1A | 
| Rated short-time thermal current: | 40kA, 1S | 
| Rated continuous thermal current: | 120%I1n | 
| Secondary winding power-frequency voltage: | 3kV, 1min | 
| Instrument security factor: | FS≤10 | 
| Dimensions: | φ50xφ110x105 | 
| Weight: | 3.1 kgs | 
GFUVE 400kv Class 1 Current Transformer LZCG530-10 in good quality
LZCK series resin split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe plus...and cable distribution boxes.The transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.

P1, P2 is primary polarity terminal, S1, S2 is secondary polarity
terminal.
P2, S2 is homonymous terminals (subtractive polarity).
| Technical parameters | |
|---|---|
| Standards | IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 | 
| Rated primary current | 20-600A | 
| Rated load | ≤25VA | 
| Rated frequency | 50Hz or 60Hz | 
| Rated secondary current | 5A or 1A | 
| Rated short-time thermal current | 40kA, 1S | 
| Rated continuous thermal current | 120%I1n | 
| Secondary winding power-frequency voltage | 3kV, 1min | 
| Instrument security factor | FS≤10 | 
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | φ50xφ110x105 | 
| Weight (kg) | 3.1 | 
| Operating conditions | |
| Operating temperature | -35°C to +55°C | 
| Daily average temp | <+40°C | 
| Altitude | <3500 meters | 
| Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. | 
| Type | LZCK350-10 | LZCK350-10 | LZCK350-10 | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Purpose | Measuring current transformer | Protection current transformer | Double winding current transformer | |||||||
| Ratio | Accuracy class and rated burden(VA) | Accuracy class and rated load (VA) | Composite accuracy class and rated load (VA) | |||||||
| I1/I2 | 0.5 | 1 | 3 | 10P15 | 10P10 | 10P5 | 0.5 | 1 | 10P10 | 10P5 | 
| 20/1 | 0.5 | 0.75 | ||||||||
| 30/1 | 0.5 | 1.5 | 0.75 | 1.25 | ||||||
| 50/1 | 1 | 2 | 1.25 | 2 | ||||||
| 75/1 | 2 | 2.5 | 3.75 | 1.25 | 2 | 3 | 2 | 1 | 2 | |
| 100/1 | 2.5 | 3.75 | 5 | 2 | 2.5 | 5 | 2 | 2.5 | 1.5 | 2.5 | 
| 200/1 | 5 | 3 | 5 | 7.5 | 2.5 | 2 | ||||
| 300/1 | 10 | 3 | 5 | 7.5 | 3.75 | 2.5 | ||||
| 400/1 | 10 | 3 | 5 | 10 | 5 | 2.5 | ||||
| 500/1 | 25 | 3.75 | 6.25 | 10 | 5 | 2.5 | ||||
| 600/1 | 25 | 5 | 7.5 | 10 | 7.5 | 5 | ||||
| 50/5 | 2.5 | 2 | ||||||||
| 75/5 | 2.5 | 3 | ||||||||
| 100/5 | 2.5 | 3.75 | 5 | 2.5 | 2.5 | |||||
| 200/5 | 7.5 | 2.5 | 5 | 2.5 | ||||||
| 300/5 | 10 | 5 | 2 | 2.5 | ||||||
| 400/5 | 15 | 7.5 | 2.5 | 5 | ||||||
| 500/5 | 25 | 7.5 | 2.5 | 5 | ||||||
| 600/5 | 30 | 10 | 3 | 7.5 | ||||||
| Model | Primary rated current | Rated load | Aperture (mm) | Description (mm) | Weight (kg) | Material | Water-proof | 
|---|---|---|---|---|---|---|---|
| LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP65 | 
| LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 | 
| LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) | 
| LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) | 
| LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) | 
| LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 2.1 | Resin | silicon case (option) | 
Be sure to the type, current ratio, accuracy class, rated load and use of the products when you plan to make a order. Special specifications could be customized.All kinds of different specifications and parameters current transformers can be made according to your needs.
|   | 
 100 / 5A Core Balance Current Transformer Dry Type 50mm Aperture 0.5% High Accuracy
                                                                                    
                        
                        
                        
                                                            100 / 5A Core Balance Current Transformer Dry Type 50mm Aperture 0.5% High Accuracy
                                                    
                        
                     4mm Banana Connector 1000A/5A Split Core Current Transformer With 110mm & 50m Diameter
                                                                                    
                        
                        
                        
                                                            4mm Banana Connector 1000A/5A Split Core Current Transformer With 110mm & 50m Diameter
                                                    
                        
                     IP68 200/5A High Magnetic Core Clamp Ct Transformer / Split Core CT For Electric Meter
                                                                                    
                        
                        
                        
                                                            IP68 200/5A High Magnetic Core Clamp Ct Transformer / Split Core CT For Electric Meter
                                                    
                        
                     ABS Cover Split Core Current Transformer CT 2.5VA Burden 0.5% High Accuracy
                                                                                    
                        
                        
                        
                                                            ABS Cover Split Core Current Transformer CT 2.5VA Burden 0.5% High Accuracy
                                                    
                        
                     FU16 333mv Mini Dual Core Current Transformer Low Phase Shift For Power Measurement
                                                                                    
                        
                        
                        
                                                            FU16 333mv Mini Dual Core Current Transformer Low Phase Shift For Power Measurement
                                                    
                        
                     200A Outdoor Split Type Current Transformer For Cable Fault Monitoring , Class 0.5
                                                                                    
                        
                        
                        
                                                            200A Outdoor Split Type Current Transformer For Cable Fault Monitoring , Class 0.5
                                                    
                        
                     Resin Cast Split Core Current Transformer 600/5A Network Switchgears Application
                                                                                    
                        
                        
                        
                                                            Resin Cast Split Core Current Transformer 600/5A Network Switchgears Application
                                                    
                        
                     GFUVE 100A / 5A Split Core  Clamp On Current Transformer IP67 Outdoor Installation
                                                                                        
                                                        
                        
                        
                        
                                                            GFUVE 100A / 5A Split Core  Clamp On Current Transformer IP67 Outdoor Installation
                                                    
                        
                     50Hz / 60Hz Split Core Current Transformer Epoxy Resin Cast CT 3.1 Kgs Weight
                                                                                    
                        
                        
                        
                                                            50Hz / 60Hz Split Core Current Transformer Epoxy Resin Cast CT 3.1 Kgs Weight
                                                    
                        
                     Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage
                                                                                    
                        
                        
                        
                                                            Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage