Sign In | Join Free | My bjjsgy.com
bjjsgy.com
Products
Search by Category
Home > Pumps >

55kw 75hp Rain River Sewage Dirty Water Dewatering Submersible Pump

Categories Submersible Sewage Pump
Brand Name: APK
Model Number: Sewage Submersible Pump
Certification: ISO; CE
Place of Origin: China
MOQ: 1 set
Price: Please contact us as below
Payment Terms: T/T, Western Union, L/C
Supply Ability: 2530 sets per month
Delivery Time: 3-5 working days after payment confirmation
Packaging Details: Sewage submersible pump is packed by wooden case.
Head meters: 50m sewage submersible pump
Flow Rate: 120m3/h sewage submersible pump
Material: Cast iron submersible pump
Voltage: 3ph 380v 50hz submersible pump
Power: 75hp 55kw submersible pump
Warranty: 24 months
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

55kw 75hp Rain River Sewage Dirty Water Dewatering Submersible Pump


China 30m3/h 40m3/h 160m3/h Electric Vertical Waste Dewatering Dirty Water Sewage Submersible Pump


Submersible sewage pump overview:

Sewage submersible pump applications

1. municipal works, industrial buildings,hotels,hospitals,civil air defense,mines.

2. Trades to drain off the sewage, waste water, rainwater and living water in cities containing solid grains and various long fabrics.

Submersible sewage pump types

1. 304/316/316L stainless steel type

2. high temperature resistent type

3. cutting impeller type.

Sewage Submersible Pump Working Conditions

1. Proper medium: liquids with chemical property similar to pure water should be non-corrosive.

2. Solid size should be no larger than 30% of the pump suction diameter. Fiber length should not be over 2.5 times of the pump suction diameter.

3. When the medium density is more than 1.05, the motor power should be increased accordingly to prevent the motor from overload operation.


Sewage submersible pump specifications:


1. Flow rate: 10m3/h-2500m3/h

2. Head meters: 6m-200m

3. power: 2.2kw-220kw

4. Voltage: 380v 420v 440v or as per request

5. Material: cast iron, SS304, SS316, SS316L

Sewage submersible pump models:

Outlet diameterModelFlowHeadPower
mmWQ typem3/hmkwhp
5050WQ10-15-1.510151.52
5050WQ15-25-3152534
6565WQ25-10-2.225102.23
6565WQ30-30-5.530305.57
8080WQ50-10-3501034
8080WQ45-22-7.545227.510
100100WQ60-10-4601045
100100WQ65-15-5.565155.57
100100WQ100-15-7.5100157.510
150150WQ145-9-7.514597.510
100100WQ100-25-11100251115
150150WQ130-15-11130151115
200200WQ300-7-1130071115
100100WQ100-30-15100301520
150150WQ100-30-15100301520
200200WQ220-12-15220121520
100100WQ100-35-18.51003518.525
150150WQ180-20-18.51802018.525
200200WQ250-15-18.52501518.525
250250WQ400-7-18.5400718.525
100100WQ100-40-22100402230
150150WQ180-25-22180252230
200200WQ300-15-22300152230
250250WQ450-7-2245072230
150150WQ160-45-30160453040
200200WQ400-13-30400133040
250250WQ600-9-3060093040
300300WQ850-7-3085073040
150150WQ180-45-45180454560
200200WQ400-25-45400254560
250250WQ600-20-55600205575
350350WQ1300-12-7513001275100

120m3/h 50m 55kw 75kw submersible sewage pump with stainless steel reamers image, ss304 impeller


Sewage submersible pump installation instructions

1. Check whether pump fasteners are loosen and whether the pump body runner is blocked by foreign matters before installation to avoid damage of impeller and pump body in running.

2. Supporters for the outlet pipe should be installed separately so that the weight will not be added to the pump so as to prevent it from deformation. The pump base for both movable and fixed installation must be leveled by a level. 2. After the base is ready, install the pump on the base and then use a level to check horizontal and vertical situation between the pump and motor shaft. Use the iron shim to change the height of the base if the pump is out of level. Then grout the base and anchor bolt holes by pouring the concrete into the grout hole.

3. The levelness of the coupling device should be calibrated by a level when coupling installation is adopted. Horizontal level tolerance should not exceed 0.1mm/m. Use the measure gage to calibrate parallelism of two coupling rods to ensure the parallelism tolerance will not exceed 0.2mm/m.

4. Tighten the anchor bolt to make sure there is no looseness between the anchor bolt and concrete in case of bad influence on pump performance when starting.

5. For easy maintenance and safe use, install a regulating valve on the outlet pipe and a pressure gauge near the outlet to guarantee the normal operation within the rated performance range, which lengthens the lifetime of pumps. Rotate the impeller from the suction side after installation. Disassemble the pump and find out the reasons if there is friction or stuck pump.

6. The pump installation can be divided into three types, movable type, fixed type and coupling type.


Submersible water pump factory showing:

APK is a professional ODM OEM electric sewage submersible pump manufacturer in China since 1996, got CE, ABS and ISO. Whether you are a trading company, distributor, end users, project planning or for a tender, we have professional sale team and technical team to service.

Quality 55kw 75hp Rain River Sewage Dirty Water Dewatering Submersible Pump for sale
Send your message to this supplier
 
*From:
*To: Zhengzhou Shenlong Pump Industry CO.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0