| Sign In | Join Free | My bjjsgy.com | 
 | 
| Categories | Cassette Fan Coil Unit | 
|---|---|
| Brand Name: | MECO or OEM | 
| Model Number: | MFP-68KM4-MK1 | 
| Certification: | CE, ISO, Rohs | 
| Place of Origin: | Taizhou, China | 
| MOQ: | 50pcs | 
| Price: | to be discussed | 
| Payment Terms: | L/C, T/T | 
| Supply Ability: | 10000pcs per month. | 
| Delivery Time: | 25-35days | 
| Packaging Details: | Standard export carton box | 
| Cooling capacity: | 3.8kw | 
| Heating capacity: | 5.9kw | 
| Air flow: | 400CFM | 
| Motor type: | AC motor | 
| Display type: | Digital display | 
| Water pump: | Build in water pump | 
| Electrical box: | Outside/build in optional | 
| Fresh air hole: | Standard available | 
| Power supply: | 110/220V 1Ph 50/60Hz | 
| Modbus: | Optional | 
| Auto restart: | Optional | 
| Finger protect: | Finger protect grill optional | 
| Drain tray: | Extra bigger drain tray optional | 
Ceiling mounted fan coil unit cooling and heating with remote controller, two pipe systems with build in electrical box
Specifications for hydronic four way cassette fan coil model MFP-68KM-MK1:
1. Air flow 400CFM,680CMH
2. Cooling capacity 3800W
3. Heating capacty 5900W
4. Two pipe system
5. With build in water pump
6. Power supply 220V-1-50Hz
7. Compact Panel size 650x650mm
Full ranges of capacities we have for M style cassette fan coil unit 2 pipe systems:
| MODEL Casstte fan coil unit 4 pipe system | air volume | COOLING CAPACITY | HEATING CAPACITY | POWER INPUT | 
| m3/h | W | W | W | |
| MFP-34KM-Q1M | 380 | 2000 | 3100 | 40 | 
| MFP-51KM-Q1M | 550 | 3000 | 4700 | 50 | 
| MFP-68KM-Q1M | 680 | 3800 | 5900 | 58 | 
| MFP-80KM-Q1M | 780 | 4200 | 6500 | 60 | 
| MFP-85KM-Q1M | 880 | 4900 | 7600 | 70 | 
| MFP-102KM-Q1M | 1050 | 5800 | 9000 | 95 | 
| MFP-130KM-Q1M | 1300 | 7000 | 10900 | 125 | 
| MFP-136KM-Q1M | 1380 | 7500 | 11600 | 130 | 
| MFP-153KM-Q1M | 1550 | 8100 | 12200 | 145 | 
| MFP-170KM-Q1M | 1750 | 9800 | 15200 | 160 | 
| MFP-204KM-Q1M | 2050 | 11000 | 17100 | 190 | 
| MFP-238KM-Q1M | 2200 | 12000 | 18600 | 210 | 
| MFP-272KM-Q1M | 2720 | 15000 | 24000 | 230 | 
| PERFORMANCE OF "M" STYLE CASSETTE TYPE FAN COIL(4-WAY,2TUBE)---DRAINED BY WATER PUMP | ||||||||||||||
| model(2 tube system) | MFP-34KM-MK1 | MFP-51KM-MK1 | MFP-68KM-MK1 | MFP-85KM-MK2 | MFP-102KM-MK2 | MFP-136KM-MK3 | MFP-153KM-MK3 | MFP-170KM-MK3 | MFP-204KM-MK3 | MFP-238KM-MK3 | MFP-272KM-MK4 | |||
| power supply | 220V,50Hz,1Ph | |||||||||||||
| air volume | H | m3/h | 380 | 550 | 680 | 880 | 1050 | 1380 | 1550 | 1750 | 2050 | 2200 | 2720 | |
| M | 300 | 440 | 540 | 700 | 840 | 1100 | 1240 | 1400 | 1640 | 1760 | 2040 | |||
| L | 230 | 330 | 410 | 530 | 630 | 830 | 930 | 1050 | 1230 | 1320 | 1360 | |||
| static pressure | Pa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | ||||
| cooling capacity | TH | H | W | 2000 | 3000 | 3800 | 4900 | 5800 | 7500 | 8100 | 9800 | 11000 | 12000 | 15000 | 
| BTU/h | 6824 | 10236 | 12966 | 16719 | 19790 | 25590 | 27637 | 33438 | 37532 | 40944 | 51180 | |||
| SH | W | 1400 | 2200 | 2850 | 3500 | 4250 | 5500 | 5880 | 7150 | 8250 | 9100 | 11175 | ||
| BTU/h | 4777 | 7506 | 9724 | 11942 | 14501 | 18766 | 20060 | 24396 | 28149 | 31049 | 38129 | |||
| TH | M | W | 1700 | 2550 | 3250 | 4150 | 4950 | 6400 | 6650 | 8350 | 9350 | 10200 | 12450 | |
| SH | W | 1150 | 1800 | 2350 | 2850 | 3500 | 4550 | 4700 | 5950 | 6850 | 7650 | 9560 | ||
| TH | L | W | 1400 | 2050 | 2600 | 3400 | 4000 | 5200 | 5420 | 6750 | 7600 | 8300 | 10300 | |
| SH | W | 950 | 1400 | 1850 | 2300 | 2800 | 3600 | 3850 | 4700 | 5450 | 6000 | 8400 | ||
| heating capacity | H | W | 3100 | 4700 | 5900 | 7600 | 9000 | 11600 | 12200 | 15200 | 17100 | 18600 | 24000 | |
| M | W | 2650 | 4000 | 5000 | 6450 | 7650 | 9850 | 10300 | 12900 | 14550 | 15800 | 19900 | ||
| L | W | 2100 | 3150 | 3950 | 5100 | 6050 | 7750 | 8140 | 10200 | 11450 | 12450 | 15200 | ||
| noise | H | 0Pa | dB(A) | 39 | 42 | 44 | 42 | 46 | 46 | 48 | 47 | 50 | 51 | 53 | 
| power input | H | 0Pa | W | 40 | 50 | 58 | 70 | 95 | 130 | 145 | 160 | 190 | 210 | 230 | 
| waterflow volume | m3/h | 0.34 | 0.51 | 0.65 | 0.83 | 0.99 | 1.28 | 1.38 | 1.67 | 1.87 | 2.04 | 2.55 | ||
| water pressure dropping | kPa | 11 | 13 | 22 | 18 | 25 | 23 | 23 | 28 | 33 | 42 | 45 | ||
| dimension of water(in & out)connection pipe | in | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ||
| out | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | ZG3/4" | |||
| coil | type | high efficient copper pipe to wear Hydrophilic aluminum coil | ||||||||||||
| dimension of water drain pipe | mm | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ¢26 | ||||
| net dimension | unit | L×W×H mm | 592*592*242 | 750*750*242 | 840*840*242 | |||||||||
|   | 
 MECO  One-way Cassette Fan Coil Unit (2 tube) capacity 0.7TR 400CFM with CE Certification
                                                                                    
                        
                        
                        
                                                            MECO  One-way Cassette Fan Coil Unit (2 tube) capacity 0.7TR 400CFM with CE Certification
                                                    
                        
                     MECO  One-way Cassette Type Fan Coil Unit (4 tube) 0.9TR 500CFM with CE Certification
                                                                                    
                        
                        
                        
                                                            MECO  One-way Cassette Type Fan Coil Unit (4 tube) 0.9TR 500CFM with CE Certification
                                                    
                        
                     MECO  One-way Cassette Fan Coil Unit (2 tube) 0.75TR 300CFM with CE Certification water fan coil unit
                                                                                    
                        
                        
                        
                                                            MECO  One-way Cassette Fan Coil Unit (2 tube) 0.75TR 300CFM with CE Certification water fan coil unit
                                                    
                        
                     MECO  One-way Cassette Type Fan Coil Unit (4 tube) 0.5TR 300CFM with CE Certification
                                                                                    
                        
                        
                        
                                                            MECO  One-way Cassette Type Fan Coil Unit (4 tube) 0.5TR 300CFM with CE Certification
                                                    
                        
                     MECO  One-way Cassette Type Fan Coil Unit (4 tube) 0.3TR 200CFM with CE Certification
                                                                                    
                        
                        
                        
                                                            MECO  One-way Cassette Type Fan Coil Unit (4 tube) 0.3TR 200CFM with CE Certification
                                                    
                        
                     MECO  One-way Cassette Type Fan Coil Unit (4 tube) 0.7TR 400CFM with CE Certification
                                                                                    
                        
                        
                        
                                                            MECO  One-way Cassette Type Fan Coil Unit (4 tube) 0.7TR 400CFM with CE Certification
                                                    
                        
                     MECO  One-way Cassette Type Fan Coil Unit (2 tube) 0.5TR 200CFM with CE Certification
                                                                                    
                        
                        
                        
                                                            MECO  One-way Cassette Type Fan Coil Unit (2 tube) 0.5TR 200CFM with CE Certification
                                                    
                        
                     MECO  One-way Cassette Type Fan Coil Unit (2 tube) 1.2TR 500CFM with CE Certification
                                                                                    
                        
                        
                        
                                                            MECO  One-way Cassette Type Fan Coil Unit (2 tube) 1.2TR 500CFM with CE Certification
                                                    
                        
                     MECO CE CERTIFIED HYDRONIC FOUR WAY CEILING CASSETTE FAN COIL UNITS 0.6TR 200CFM with fresh air hole,build in water pump
                                                                                    
                        
                        
                        
                                                            MECO CE CERTIFIED HYDRONIC FOUR WAY CEILING CASSETTE FAN COIL UNITS 0.6TR 200CFM with fresh air hole,build in water pump
                                                    
                        
                     MECO CE CERTIFICATION FOUR WAY CEILING CASSETTE FAN COIL UNITS 0.8TR 300CFM with digital display , build in water pump
                                                                                    
                        
                        
                        