| Categories | Defibrillator Machine Parts | 
|---|---|
| Brand Name: | Primedic | 
| Model Number: | M240 DM1 Defibrillator | 
| Certification: | CE/CB/ROSH | 
| MOQ: | 1 | 
| Price: | USD | 
| Payment Terms: | L/C, D/A, D/P, T/T | 
| Packaging Details: | Carton | 
| Brand: | Metrax Primedic M240 DM1 Defibrillator SpO2 Module | 
| Color: | White | 
| Category: | Defibrillator SpO2 Module | 
| Wattanty: | 90 Days | 
| Packing weight: | 1.5kg | 
| size: | Uniform size | 
| Application area: | ICU,medical equipment | 
| Condition: | used or new | 
| Estimated Ship Time: | 3-5 Business Days | 
| In stock: | 300 Pieces | 
| Specification: | 18*16cm | 
| Used for: | M240 DM1 Defibrillator | 
| net weight: | 0.6kg | 
| Shape: | standard | 
| Company Info. | 
| China World Technology Medical Equipment Service Group | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Metrax Primedic M240 DM1 Defibrillator SpO2 Module,Includes Connecting Cable And SpO2 Module
The SPO2 module is used for sampling examination or measuring the patient's blood oxygen saturation and pulse rate. For average blood oxygen saturation, the low-power module can send instantaneous blood oxygen saturation. Its detection speed is very efficient and the SPO2 module is compatible with all BCI probes. This module is suitable for measuring blood oxygen saturation and pulse rate in infants, newborns and adults.
If there is a fault, there will be no blood oxygen waveform or blood oxygen value.
1. Replace the blood oxygen probe. If it doesn't work, the blood
oxygen probe or blood oxygen extension cable may be faulty.
2. Check whether the blood oxygen probe model matches.
3. Check whether the red light of the blood oxygen probe is
flashing. If it does not flash, the probe assembly is faulty.
4. If a blood oxygen "initialization error" alarm occurs, the blood
oxygen module is faulty.
If the finger probe does not have a red light flashing, it may be a poor contact at the wire interface. It is recommended to check extension cords and socket connections. In areas with lower temperatures, try not to expose the patient's arms to avoid affecting the detection effect. Blood pressure measurement and blood oxygen measurement should not be performed on the same arm to avoid pressure on the arm and affect the measurement results. If the blood oxygen display waveform channel displays "No signal reception", it means there is a problem with the communication between the blood oxygen module and the host. Please close and then open again. If this prompt continues to appear, the blood oxygen module needs to be replaced.
If the SPO2 value is low or inaccurate, there are several checking methods:
1. First we have to ask whether this is a specific case or a
general phenomenon. If it is a special situation, you can consider
how to avoid it from the precautions of blood oxygen measurement,
such as patient movement, poor microcirculation, hypothermia, too
long time, etc.
2. If this is a common situation, please try to replace the blood
oxygen probe. It may be caused by a faulty blood oxygen probe.
3. Check whether the blood oxygen extension cable is damaged.
Try to keep the patient as stable as possible. Once the blood
oxygen value is lost due to hand movements, it is considered
normal. If the blood oxygen extension cable is damaged, please
replace it with a new one.


| Brand | Primedic | 
| Type | M240 DM1 Defibrillator SpO2 Module | 
| Warranty period | 90 Days | 
| Shipping Date | 3-5 Working Days | 
| size | 18*16cm | 
| Storage temperature | -20-70°c | 
We default to express delivery by DHL,Fedex, We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.
|   | 
 LM34S001A Defibrillator Machine Parts Hospital Aed Lithium Battery
                                                                                    
                        
                        
                        
                                                            LM34S001A Defibrillator Machine Parts Hospital Aed Lithium Battery
                                                    
                        
                     UR-0313 Defibrillator Machine Parts Japan Philipotoelectric Instrument  Defibrillator Board Repair
                                                                                    
                        
                        
                        
                                                            UR-0313 Defibrillator Machine Parts Japan Philipotoelectric Instrument  Defibrillator Board Repair
                                                    
                        
                     GE Pro1000 Patient Monitor Parts , 3 Channel Ecg Board Replacement
                                                                                    
                        
                        
                        
                                                            GE Pro1000 Patient Monitor Parts , 3 Channel Ecg Board Replacement
                                                    
                        
                     XL+ Defibrillator Machine Parts Dia5cm Defibrillator Capacitor
                                                                                    
                        
                        
                        
                                                            XL+ Defibrillator Machine Parts Dia5cm Defibrillator Capacitor
                                                    
                        
                     M3535A M3536A M3538A Philip Heartstart Defibrillator Battery Replacement
                                                                                    
                        
                        
                        
                                                            M3535A M3536A M3538A Philip Heartstart Defibrillator Battery Replacement
                                                    
                        
                     ICU Defibrillator Machine Parts Philip M4735A Heart Defibrillator Printer
                                                                                    
                        
                        
                        
                                                            ICU Defibrillator Machine Parts Philip M4735A Heart Defibrillator Printer
                                                    
                        
                     Philip M4735A used Defibrillator Printer M4735A-60030 Cover Case Parts
                                                                                    
                        
                        
                        
                                                            Philip M4735A used Defibrillator Printer M4735A-60030 Cover Case Parts
                                                    
                        
                     Philip M3535A M3536A Heart Defibrillator Printer Repair
                                                                                    
                        
                        
                        
                                                            Philip M3535A M3536A Heart Defibrillator Printer Repair
                                                    
                        
                     BeneHeart D3 D6 Mindray Defibrillator External Paddles And Cables 0651-30-76994
                                                                                    
                        
                        
                        
                                                            BeneHeart D3 D6 Mindray Defibrillator External Paddles And Cables 0651-30-76994
                                                    
                        
                     Parts Of Philip Effica DFM100 Defibrillator External Steralizable Paddles 453564810911 SN CNPA139051
                                                                                    
                        
                        
                        
                                                            Parts Of Philip Effica DFM100 Defibrillator External Steralizable Paddles 453564810911 SN CNPA139051