| Sign In | Join Free | My bjjsgy.com | 
              
  | 
      
| Categories | Leak Testing Equipment | 
|---|---|
| Brand Name: | HJ | 
| Model Number: | HJ089 | 
| Certification: | Calibration Certificate(Cost Additional) | 
| Place of Origin: | China | 
| MOQ: | 1 set | 
| Price: | Negotiatable | 
| Payment Terms: | T/T, L/C | 
| Supply Ability: | 10 Set per month | 
| Delivery Time: | 90 Days | 
| Packaging Details: | Plywood | 
| Workpiece: | Heating tank | 
| Vacuum chamber: | 1 chamber (each chamber can test 2 work pieces) | 
| Chamber size: | L700mm*W300mm*H600mm | 
| Maximum workpiece size: | Ø240*400 | 
| Equipment accuracy: | 5x10-6mbar.L/s | 
| Helium Recovery: | Recovery Rate ≥95% | 
| Company Info. | 
| HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
The Intelligent Helium Leak Detection System operates based on the principle of using helium as a tracer gas. Helium is injected into the workpiece, and the leakage accuracy is then detected rapidly and precisely by the helium leak detector.
Main Power Supply: It demands a three-phase five-wire 380VAC power source with a power of 15KW. Eight air switches are needed, which should be installed at a height of ≥1.5M from the ground and within a distance of ≤2M from the main equipment placement position.
Gas Supply:
1.Helium: At least 1 bottle of 40 liters 12MPa bottled helium with a 0.1MPa pressure reducing valve.
2.High-purity nitrogen: Bottled high-purity nitrogen (≥99.999%) with a 0.2MPa pressure reducing valve.
3.Compressed air: Clean compressed air with a pressure ranging from 0.55 - 0.7MPa. The gas supply interfaces must be within a distance of ≤1M from the machine placement position.
4.Others: An outdoor exhaust pipe with a diameter of ≥3/4″ is required, and its interface should be within a distance of ≤1M from the machine placement position.
Workpiece  | Heating tank  | 
|---|---|
Vacuum chamber  | 1 chamber (each chamber can test 2 work pieces)  | 
Chamber size  | L700mmW300mmH600mm  | 
Maximum workpiece size  | Ø240*400  | 
Equipment accuracy  | 5x10⁻⁶mbar.L/s  | 
Helium Recovery  | Recovery Rate ≥95%  | 
Product Image with Leak Testing Equipment:



                                 
                             |