NEMA34 Closed Loop Stepper Motor Driver JK-HSD86 20V ~ 80VDC 0.1A - 10A

 
Electrical Specifications
 

Parameter Min Typical Max Unit
Input Voltage (JK-HSD86)2036 4850VDC
Input Voltage (JK-HSD86C)2436 4880VDC
Input Voltage (SC8680C)24VAC60AC80VAC 100VDCVVDC
Output Current 0.1-10(Peak)A
Pulse Input Frequency 0-200kHz
Logic Signal Current 71016mA
Isolation Resistance 500--

 
 
Operating Environment
 

Cooling Natural Cooling or Forced cooling
Operating Environment EnvironmentAvoid dust, oil fog and corrosive gases
Storage Temperature-20℃ - 65℃ (-4℉ - 149℉)
Ambient Temperature0℃ - 50℃ (32℉ - 122℉)
Humidity40%RH - 90%RH
Operating Temperature70℃ (158℉) Max
(Heat Sink)
Weight 580 g (20.5 oz)

 
 
Connectors and Pin Assignment
The JK-HSD86 has four connectors, connector for control signals connections, connector for status signal connections,connector for encoder feedback and connector for power and motor connections.
 

Control Signal Connector Screw Terminal
Pin Name I/O Description
    
1 PUL+ IPulse Signal: In single pulse (pulse/direction) mode, this input represents pulse signal, each
rising or falling edge active (software configurable, see easy servo drive software manual for
more detail); In double pulse mode (software configurable), this input represents clockwise
   
2 PUL- I
(CW) pulse, active both at high level and low level. 4.5-28V when PUL-HIGH, 0-0.5V when
PUL-LOW. For reliable response, pulse width should be longer than 2.0μs.
    
3 DIR+ IDirection Signal: In single-pulse mode, this signal has low/high voltage levels, representing
two directions of motor rotation. In double-pulse mode (software configurable), this signal
is counter-clock (CCW) pulse, active both at high level and low level. For reliable motion
   response, DIR signal should be ahead of PUL signal by 2us at least. 4.5-28V when DIR-HIGH,
4 DIR- I
0-0.5V when DIR-LOW. Please note that rotation direction is also related to
motor-driver-encoder wiring match. Exchanging both the connection of two wires for a coil
and an encoder channel to the driver he connection will reverse motion direction. Or you
can toggle the SW5 to reverse the motion direction.
    
5 ENA+ IEnable Signal: This signal is used for enabling/disabling the driver. In default, high level
(NPN control signal) for enabling the driver and low level for disabling the driver. Usually
   left UNCONNECTED (ENABLED). Please note that PNP and Differential control signals are on
6 ENA- I
the contrary, namely Low level for enabling. The active level of ENA signal is software
configurable.

 
Dimension:

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company CHANGZHOU JKONGMOTOR CO.,LTD
Location Building A2,Hutang Industrial zone,Lingdao Rd,Wujin District,Changzhou,China.Zip:213162
Contact Person Annie

Request A Quote

Please check your email address.
Your message must be at least 20 characters.