PCB Mounting Closed Loop Hall Effect Current Sensor For DC Motor Drives
PCB Mounting Closed Loop Hall Effect Current Sensor For DC Motor Drives
Hall Effect Current Sensor description:
The TBC- AP series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
Hall Effect Current Sensor Electrical data(Ta=25℃±5℃)
|
Model
|
TBC025AP | TBC50AP | TBC100AP | TBC125AP | TBC200AP | Unit |
Rated input(Ipn) |
25 | 50 | 100 | 125 | 200 | A |
| Measure range(Ip) | 75(±18V, 180Ω) |
150(±18V, 80Ω) |
300(±18V, 68Ω) |
375(±18V, 15Ω) |
600(±18V, 10Ω) |
A |
| Turnsratio(Np/Ns) | 1:1000 | 1:1000 | 1:2000 | 1:1000 | 1:2000 | |
Coil resister |
45.00 | 30.00 | 45.00 | 30.00 | 45.00 | Ω |
Rated output(Is) |
25±0.5% | 50±0.5% | 50±0.5% | 125±0.5% | 100±0.5% | mA |
| Supply voltage | ±12~±18 | V | ||||
| Power consumption | 20+IpX(Np/Ns) | mA | ||||
| offset current | @Ip=0 ≤±0.2 | mA | ||||
| Offset current drift | @ -40~+85℃ ≤±0.5 | mA | ||||
| Linearity | @Ip=0-±Ipn ≤0.1 | %FS | ||||
| Bandwidth | @ -3dB 0~200 | KHz | ||||
| Response time | @100A/μS,10%-90% ≤1 | µs | ||||
| Galvanic isolation | @ 50HZ,1min 3.0 | KV | ||||
Hall Effect Current Sensor Applications
- AC variable speed drives and servo motor drives
- Static converters for DC motor drives
- Variable speed drives
- Power supplies for welding applications
- Battery supplied applications
- Uninterruptible Power Supplies (UPS)
- Switched Mode Power Supplies(SMPS)
Hall Effect Current Sensor Mechanical dimension(for reference only)
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
Hall Effect Current Sensor Directions for use
- When measure current flows according to the direction of the arrowhead, Output terminal gets the same phase current.
- The primary conductor should be≤120℃.
- The dynamic performance (di/dt and the response time) is the best when the primary hole is fully filled with
- the bus bar.
- The primary turns should be at the top of the sensor for the best magnetic coupling.
- When the current will be measured goes through a sensor, the voltage will be measured at the output end.
- (Note: The false wiring may result in the damage of the sensor)
- Custom design in the different rated input current and the output current are available.
Hall Effect Current Sensor Standards
- UL94-V0.
- EN60947-1:2004
- IEC60950-1:2001
- EN50178:1998
- SJ 20790-2000
Hall Effect Current Sensor General date
| Value | Unit | Symbol | |
| Operating temperature | -40 to +85 | ºC | TA |
| Storage temperature | -40 to+125 | ºC | TS |
| Mass(approx) | 25 | g | M |
Hall Effect Current Sensor Characteristics chart
Pulse current signal response characteristic Effects of impulse noise

Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.