TBV-LV Hall Effect Voltage Sensor Dc Voltage Transducer Blue And Black
TBV-LV Hall Effect Voltage Sensor Dc Voltage Transducer Blue And Black
TBV-LV series current mode voltage sensor is a device based on the principle of the hall effect, with a galvanic isolation between primary and secondary circuit, It provides accurate electronic measurement of DC,AC or pulsed voltage.
Electrical data(Ta=25℃±5℃)
| Type Parameter |
TBV 100LV |
TBV 200LV |
TBV 300LV |
TBV 500LV |
TBV 1000LV |
TBV 2000LV |
TBV 3000LV |
TBV 4000LV |
Unit |
Rated input (Vpn) |
100 | 200 | 300 | 500 | 1000 | 2000 | 3000 | 4000 | V |
Measure range(Vp) |
200 | 400 | 600 | 1000 | 2000 | 4000 | 6000 | 6000 | V |
|
Total input consumption |
0.25 | 0.50 | 0.75 | 1.25 | 2.5 | 5.0 | 7.5 | 10 | W |
|
Rated input (Ip) |
2.5 | mA | |||||||
|
Turns ratio(Np/Ns) |
20000:1000 | T | |||||||
|
Secondary coil resister |
@ +85℃ 55 | Ω | |||||||
Rated output (Isn) |
@Vp=±Vpn ±50±0.5% | mA | |||||||
|
Resister measured |
@ ±15V VPN 50(min), 200(max) | Ω | |||||||
| @ ±15V 2XVPN 0(min), 100(max) | Ω | ||||||||
| @ ±24V VPN 100(min), 330(max) | Ω | ||||||||
| @ ±24V 2XVPN 100(min), 200(max) | Ω | ||||||||
Supply voltage |
±15 - ±24 | V | |||||||
Consumption current |
20+IpX(Np/Ns) | mA | |||||||
Offset current |
@ Vp=0 ≤±0.2 | mA | |||||||
Offset drift |
@ -40~+85℃ ≤±0.6 | mA | |||||||
Linearity |
@ Vp =0-±Vpn ≤0.1 | %FS | |||||||
Response time |
≤200 | uS | |||||||
Galvanic isolation |
@ 50HZ,AC,1min Between primary and secondary + shield 12.0 | KV | |||||||
| @ 50HZ,AC,1min Between secondary and shield 2.0 | KV | ||||||||
Applications
Variable speed drives
Power supplies for welding applications
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies(SMPS)
Mechanical dimension(for reference only)
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
Directions for use
Is is positive when the Ip is applied to the terminal +HT. Temperature of the primary conductor should not exceed 100℃.
When the voltage will be measured goes through a sensor, the current will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor)
Custom design in the different rated input voltage and the output current available.
Standards
- UL94-V0.
- EN60947-1:2004
- IEC60950-1:2001
- EN50178:1998
- SJ 20790-2000
General date
| Value | Unit | Symbol | |
| Operating temperature | -40 to +85 | ºC | TA |
| Storage temperature | -40 to +125 | ºC | TS |
| Mass(approx) | 43 | g | M |
Effects of impulse noise
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.

