Thermal Profiler for Confirmation of Communication between PC and Instrument

Price Negotiable
Price: Negotiable
MOQ: 1 pc
Delivery Time: 3~5days
Brand: KIC
Product Description

KIC2000 Profiler for Process Optimization & Lower Energy Use

 

Features

 

1, Transmit reception frequency: 433.92MHz

2, Full Original Package, with original Thermal Couples, Protective Shield, Software, etc

3, Technical Support and Warranty from USA

4, Thermal Process Optimization for Lower Energy Use

5, Standard SPC charting software include CpK, Help reveal change in the profile over time

6, Standard Profile Overlay, show different process.

7, Robust and Compact Hardware with 1 year warranty

8, 9 and 12 Channels (Standard Type K TC connectors)

 

Specifications

 

Accuracy ±1.2°C
Resolution Variable 0.3 to 0.1°C
Internal Operating Temp 0°C to 105°C
Thermocouple Compatibility Type K, 9 or 12 TCs
Temperature Range -150°C to 1050°C
Computer Capability PC
Power Requirements 9V alkaline battery
Thermal Receiver 433.92 MHz
Dimensions See Temperature Tolerance Chart below for specifications.

 

 

Matters needing attention

 

1. Check if the battery is fully charged and the surface temperature should not exceed 40'C. To test accuracy, please try to start the test at a surface temperature below 40 ℃.

 

2.Confirmation of communication between PC and instrument: The instrument thermocouple needs to detect and collect constant temperature before entering the next testing step.

 

3.The insulation box can withstand a maximum temperature of 280 ℃ for 9 minutes. mKIC, please ensure that the internal temperature of the instrument does not exceed 85 ℃ beyond this range.

 

4.If not in use for a long time, please turn off the power and remove the battery. If you need to use it, please try to store the battery in an environment below 60 ° C. If there is a continuous noise when the power is turned on for a long time, please check if the battery is low and replace it. The normal sound is about 5 seconds apart, with a few sounds.

 

5.When passing through the furnace, please make sure to cover the insulation box and hear a "click" sound to seal the yellow insulation cotton.

 

6.Only one XimC2000 furnace temperature tester recorder can be connected to the computer at a time. It is not possible to connect multiple recorders to the same USB port on the computer at the same time and select one of them.

 

7.After passing through the furnace again, wait for the insulation box to cool down before using it again.

 

About Packaging

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Hansome Technology Co., Ltd.
Location 3rd Floor,Building A,Sha Tang Bei Fang Yong Fa Industrial Area,Sha Jing, Bao an, Shenzhen, China
Contact Person Rudi Jin

Request A Quote

Please check your email address.
Your message must be at least 20 characters.