HX-Series 7000ppm Brackish Water RO System | 21-126 GPM Flow Rate | 99.8% Salt Rejection
Price:
Negotiable
MOQ:
1 Set
Delivery Time:
15~30 days
Brand:
Fenigal/OEM
Product Description
High-Performance Brackish Water Reverse Osmosis System
The HX-Series Reverse Osmosis Systems are engineered for demanding feedwater conditions with high dissolved solids content up to 7,000 ppm TDS. These industrial-grade systems deliver robust performance for brackish water applications requiring high operating pressures.
System Overview
Designed specifically for challenging water sources, the HX-Series effectively reduces total dissolved solids in both municipal and well water while producing substantial volumes of permeate water. Standard production ranges from 21 to 126 gallons per minute (30,200 to 181,400 gallons per day), with extended capacity options available from 5 to 360 gallons per minute.
Key Features
- 8-inch low energy membrane elements for efficient operation
- Fiberglass membrane housings with 316L stainless steel side ports (450 psi rating)
- 5-micron sediment filters with multi-cartridge stainless steel housing
- Vertical 316L stainless steel multi-stage pump
- Pre-programmed computer controller with variable frequency drive
- Low and high pressure shut-off switches for system protection
- Comprehensive monitoring with TDS probes, pressure gauges, and flow indicators
- Stainless steel high pressure piping and valves
- Clean-in-place ports with valves for maintenance
Standard Specifications
| Model Series | HX-2280 to HX-6480 |
|---|---|
| Maximum Feedwater TDS | 7,000 ppm |
| Standard Recovery Rate | 58% to 73% |
| Nominal Salt Rejection | 99.8% |
| Permeate Flow Rate Range | 21-126 gpm (79.5-477 lpm) |
| Operating Pressure | Up to 350 psi (24 bar) |
| Motor Power Range | 15-50 HP (11-37 KW) |
| Standard Voltage | 460V, 60Hz, 3PH |
Available Options & Upgrades
- Programmable Logic Controller (PLC) with touch screen interface
- Digital paddlewheel sensors for permeate and concentrate
- Motorized ball valves for feed and permeate control
- Permeate flush system
- pH and ORP sensors
- Clean-in-place skid mounted system
- Chemical feed system
- Multiple voltage options: 220VAC 3PH/60Hz, 220VAC 3PH/50Hz, 380VAC 3PH/50Hz
Operating Parameters
| Parameter | Value |
|---|---|
| Design Temperature | 77°F / 25°C |
| Maximum Feed Temperature | 85°F / 29°C |
| Maximum SDI Rating | < 3 |
| Maximum Free Chlorine | 0 ppm |
| Maximum Feed Pressure | 85 psi / 6 bar |
| Maximum Piping Pressure | 400 psi / 28 bar |
| pH Range (Continuous) | 2 - 11 |
Note: System performance varies with water conditions. Permeate flow increases at higher temperatures and decreases at lower temperatures. Computer projections required for applications outside standard operating limits.