Electro-Deionization Water Purification System
The Electro-Deionization (EDI) process represents the latest advancement in deionized water treatment technology, delivering ultrapure water for demanding industrial applications. EDI utilizes ion exchange resins combined with a DC voltage potential to effectively remove cation and anion contaminants from feed water supplies.
Advanced ion selective membranes within the modules continuously extract these contaminants and discharge them through a concentrated waste stream. The applied voltage enables electrochemical water splitting into hydrogen (H+) and hydroxide (OH-) ions within the ion exchange resins, facilitating continuous regeneration without chemical additives, wastewater neutralization requirements, or system downtime.
Industrial Applications
Power Generation
Chemical Manufacturing
Electronics / Semiconductor Production
Industrial Process Water
Boiler Feed Systems
Research Laboratory Facilities
Operating Parameters
Nominal Recovery: 90-95%
EDI Water Quality: 15-18 meg-ohm
Operating Temperature: 50-100°F
Maximum Inlet Pressure: 100 psig
Minimum Inlet Pressure: 60 psig
Expected Pressure Drop: 30-40 psig
Electrical Requirements: 460 VAC, 3-phase, 60 Hz or 120 VAC, 1-phase, 60 Hz
Materials of Construction
Skid Frame: Epoxy-coated carbon steel
EDI Housings: FRP (Fiber Reinforced Plastic)
System Piping: Schedule 80 PVC
EDI Cell Tubing: Polyethylene
System Specifications
MODEL MEDI-25 MEDI-50 MEDI-100 MEDI-150 MEDI-200
EDI Water Production Rate (GPM) 25 50 100 150 200
Quantity of EDI Cells 1 2 4 6 8
Maximum Current Load at 350 VDC (Amp) 6 12 24 36 48
Inlet Feed Water Rate (GPM) 28 55 110 166 220
Maximum Water to Drain (GPM) 3 5 10 16 20
System Dimensions (LxWxH) 92"x48"x73" 100"x48"x73" 133"x48"x73" 133"x48"x84" 133"x48"x84"
Shipping Weight (LBS) 2,200 2,500 3,000 3,750 4,400
Feedwater Requirements
Parameters Requirement
Feed Conductivity (including CO2) < 10 µs/cm
pH 7-10
Silica (Reactive) < 0.1 ppm
Total Hardness as CaCO3 < 0.1 ppm
TOC < 0.1 ppm
Heavy Metals (Fe, Mn etc.) < 0.01 ppm
Free Chlorine as Cl2 < 0.05 ppm
Standard specifications are based on typical applications and incoming water quality from a Two-Pass Reverse Osmosis (RO) System. Specifications may be altered to meet certain site conditions and changes in incoming and/or product water quality requirements. Dimensions and shipping weights are estimated only. Actual dimensions and weights differ depending upon the final system design and options selected.
MEDI-200 EDI Water Purification System showing industrial installation and control panel Close-up view of EDI module components and water treatment process flow

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Wuxi Fenigal Science & Technology Co., Ltd.
Location 606#, Building-B, Dicui Rd. 100, Binhu, Wuxi, Jiangsu, China
Contact Person Joe Zu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.