GL-208 High Chlorine COD Digester

Price Negotiable
Price: 200~3000USD
MOQ: 1
Delivery Time: Negotiable
Brand: Zetron
Product Description
GL-208 High Chlorine COD Digester
Product Specifications
Executive standard National standard HJ/T70-2001
Digestion quantity 6 (special for high chlorine wastewater COD)
Digestion bottle capacity 250ml (24 # ground conical flask)
Digestion sample quantity 20ml
Measurement range 30 ~ 700mg/L
(Chloride concentration is less than 20000mg/L)
Measurement error relative standard deviation of potassium hydrogen phthalate standard solution (500mg/L) ≤ 5.0%; relative standard deviation of industrial organic wastewater (500mg/L) ≤ 8.0%;
Digestion time nitrogen, 2 hours recommended (user can adjust)
Heating power 1600W (user can adjust)
Ambient temperature ≤ 35 ℃
Heating panel microcrystalline glass panel
Instrument size 440mm × 330mm × 570mm
Overview

The high-chlorine COD digester follows the national standard: determination of chemical oxygen demand in high-chlorine wastewater chlorine correction method. The chemical solution preparation, operation and COD calculation of the instrument follow HJ/T70-2001. It is applicable to the determination of COD in high-chlorine wastewater with chloride ion content less than 20000 mg/L.

Features
  • Imported microcrystalline panel is adopted, which can withstand high temperature of 700 ℃, with uniform heating, fast rising/falling speed, smooth surface and easy cleaning and maintenance.
  • New type of high temperature resistant ceramic fiber heating plate, uniform heat receiving/conducting, less heat loss.
  • The glass burr return pipe and cooling system have good digestion return effect to ensure the parallelism and accuracy of digestion results.
  • Digital display of microcrystalline panel temperature, digital display of digestion time: temperature and timing can be set at any time.
  • After digestion, the equipment will automatically stop heating, and the fan will continue to work for 120 minutes to assist sample cooling, and unattended operation is allowed.
Application area

It is suitable for the determination of COD in wastewater from oil fields, coastal refineries, oil depots, chlor-alkali plants, wastewater deep sea discharge, etc.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing HiYi Technology Co., Ltd
Location Room 1302,Yufei Building, 42 Dongzhimenwai Street, Dongcheng District, Postcode:100027 Beijing,China
Contact Person Lisa Niu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.