Galvanized Steel Sheet HVAC Fire Dampers Rust Proof Electric Reset

Price Negotiable
Price: Negotiation
MOQ: 1 Set
Delivery Time: To be negotiated
Brand: SX
Product Description

Fire Damper

* Manual control type
* Normally open, the valve will close after the break-down of fuse when the temperature reaches high degrees , stop the smoke to extend along the air duct.
* It can work as a volume control damper when open to adjust the air volume. The blade is reset by manually.

 

Fire dampers are passive fire protection products used in heating, ventilation, and air conditioning (HVAC) ducts to prevent the spread of fire inside the ductwork through fire-resistance rated walls and floors. Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to close the damper blades. Fire dampers can also close following receipt of an electrical signal from a fire alarm system utilising detectors remote from the damper, indicating the sensing of heat or smoke in the building occupied spaces or in the HVAC duct system.

 

Fire damper performance parameter table
Serial number name performance parameters
1 Standard flange specifications Valve long side b or diameter D (mm) Flange side width (mm)
D≤280 20
280≤D≤630,b≤630 25
630<D1250,630<b≤1250 30
1250<D≤2000,1500<b≤2500 40
D>2000,2500<b≤4000 50
2 Temperature sensor valve static nominal operating temperature 70℃ (valve closes automatically)
3 Material Valve body 2~3mmQ235-A
Bles 2mm708-88 Cold rolled plate
Axshaft GB905-82 Cold pull round steel Ф12
Axft sleeve Oil-containing metallurgical powder copper sleeve
4 Local resistance coefficient Resistance coefficient of ≤ 0.5 at full opening
5 Paint treatment Ground floor rust proof primer (second floor), outer fire proof paint (medium ash steel paint)
6 Rated voltage DC24V±10%
Rated current 0.7A
Micro switch AC380V,3A
Torque 10~70Kg.f/cm
Action mode automatic, electric, manual or 70℃ to close the valve
7 Fire control valve Reset method (open state) Manual reset
Smoke and fire control valve Manual reset
Smoke and fire damper Manual reset
Remote control smoke and fire damper Remote control manual reset
Automatic reset fire damper Electric reset
8 Air leakage In the standard state, when the pressure difference on both sides of the valve is 500Pa after the valve is closed, no more than 700mm³/㎡/h

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Henan Shuangxin Fire Environmental Protection Equipment Manufacturing Co., Ltd.
Location Room 1308, Building 3, Yabao International Building, at the intersection of Jinshui East Road and Xinyi Road, Zhengzhou
Contact Person Alios Lee

Request A Quote

Please check your email address.
Your message must be at least 20 characters.