Product Description

【Product name】

Diagnostic Kit for Interleukin-6(Immunochromatographic assay)

 

【Packing specification】

25 Tests/kit

 

【Intended use】

The kit is used for quantitative determination of Interleukin-6 (IL-6) in human whole blood, plasma and serum.

Interleukin 6 is a member of the family of interleukins. It plays an important role in the inflammatory response and is a sensitive indicator for the early diagnosis of acute infection.

 

【Components】

Name Quantity Component
Test cards 25 It is composed of fluorescent pad (coated with fluorescently-labeled IL-6 monoclonal antibody), nitrocellulose membrane (coated with IL-6 monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing.
Sample diluent 25 (0.3mL/ tube) Phosphate buffer
ID card 1 With specific stand curve file

The components in different batches of kits cannot be used interchangeably.

 

【Storage conditions and validity】

The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

 

【Applicable instrument】

NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.

 

【Test procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the ID card. The test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
  3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
  4. Place the test card on a clean horizontal table and mark it horizontally.
  5. Mix 100 µL of patient sample with 300µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, read and record the results at 10 minutes after addition of samples, then dispose of used test appropriately.

 

【Reference interval】

The normal reference value is less than 10pg/mL in this assay. It is strongly recommended that each laboratory should determine its own normal and abnormal values.

 

【Performance】

1. Limits of detection

No higher than 5.00 pg/mL.

2. Accuracy

The relative deviation from the target value is limited to ±15.0%.

3. Repeatability

The within and between assay coefficient of variations are within 15.0%.

4. Linearity range

Within the linear range (5.00~ 4000.00)ng/mL, the linear correlation coefficient R≥0.990.

 


 


FAQ

 

Q1: Are you trading company or manufacturer?
A1: We are manufacturer.

 

Q2: Do you provide samples ?
A2: Yes,we do provide samples.If you need it, please contact us.

 

Q3: How about the quality?
A3: We have the best professional engineer and strict QA and QC system to ensure you get high quality products from us.

 

Q4: How’s the package?
A4: Normally are cartons, but also we can pack it according to your requirements.

 

Q5: How’s the delivery time?
A5: It depends on the quantity you need.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company WWHS Biotech.Inc(marketed by Dawin)
Location Rm 505, 1st Building, Shenzhen Biomedicine Innovation Industrial Park, No. 14th, Jinhui Road, East Jinxiu Road, Kengzi Street, Pingshan District, Shenzhen
Contact Person Richard

Request A Quote

Please check your email address.
Your message must be at least 20 characters.