IEC 60950 Flammability Test Equipment with 33A Arc Current and 800×700×1600mm Chamber for Electrical Safety Testing

Price Negotiable
Price: To be quoted
MOQ: 1
Delivery Time: 20 working days
Brand: KINGPO
Product Description
Product Overview
IEC 60950 Flammability Test Equipment is designed for comprehensive arcing resistance testing of electrical and electronic products. This professional testing system evaluates the arc resistance performance of insulating materials under specified voltage conditions.
Compliance Standards
Meets international standards including IEC 60950-1, BS EN 60950-1, BS 7002, UL746A, IEC60947.1, and IEC730.1 for reliable and certified testing results.
Application Scope
Suitable for arcing resistance testing of electrical and electronic products, household appliances, and their materials. Specifically designed for information technology equipment and low voltage switch and control equipment components.
Key Features
  • Dual electrode system with copper and stainless steel construction
  • Precise current control at 33A ±0.5A with power factor COSφ 0.5
  • Automated arc strike operation at 40 times/min frequency
  • Programmable arc strike counter with 0-9999 preset capability
  • Integrated lighting and exhaust system in test chamber
  • Electrical control with button operation interface
Technical Specifications
Parameter Specification
Working Voltage 110V/60Hz
Arc Strike Current 33A ±0.5A at power factor 0.5
Arc Strike Speed 40 times/min
Electrode Separation Velocity 254 ±25 mm/s
Electrode Material Static: Copper Ø3.5mm × 152mm, 30° bevel
Moving: Stainless Steel Ø3.5mm × 152mm, 60° cone
Test Chamber Dimensions 800 × 700 × 1600 mm (L×W×H)
Equipment Weight 300 kg
Safety & Operation Guidelines
Important Safety Instructions
  • Do not start testing when current/voltage regulators are on high gear to prevent circuit breaker tripping
  • Regular electrode maintenance required after each test cycle
  • Ensure complete door closure for safety interlock activation
  • Maintain adequate ventilation and regular exhaust fan inspection
  • Proper grounding protection required for power supply

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.