OBM Multiscene Mask Testing Equipment , ASTM Bacterial Filtration Efficiency Tester
Price:
Negotiable
MOQ:
1 set
Delivery Time:
Negotiable
Brand:
Lixian
Product Description
HZ-9514 Bacterial Filtration Efficiency Tester (BFE)
Equipment Overview
It used to test the percentage of respirator material removed from the bacteria - containing suspended particles at a specified flow rate. The dual-air path sampling method improves the accuracy of sampling, which is applicable to the performance test of bacterial filtration efficiency of medical surgical masks by metrological verification departments, scientific research institutes, medical mask manufacturers and other relevant departments
Standardization
- Q/0212 ZRB003-2011 Surgical mask Bacterial filtration efficiency (BFE) detector
- YY0469-2004 Surgical mask Bacterial filtration efficiency (BFE) detector technical request
- YY/T 0969-2013 Standard for bacterial detection of disposable medical masks
- ASTMF2100 Performance specifications of materials for medical masks
- ASTM F2101 - 19 Standard Test Method for Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials
- EN 14683-2014 Medical face masks - Requirements and test methods
Technical Parameters
| Main Parameter | Parameter Range | Resolution | Max Error |
| A Sampling rate | 28.3L/min | 0.1L/min | Exceed±2.5% |
| B Sampling rate | 28.3L/min | 0.1L/min | Exceed±2.5% |
| Spray flow | (8~10)L/min | 0.1L/min | Exceed±5.0% |
| Peristaltic pump flow | (0.006~3.0)mL/min | 0.001ml/min | Exceed±2.5% |
| A Flowmeter front pressure | (-20~0)kPa | 0.01kPa | Exceed±2.5% |
| B Flowmeter front pressure | (-20~0)kPa | 0.01kPa | Exceed±2.5% |
| Spray flowmeter front pressure | (0~300)kPa | 0.1kPa | Exceed±2.5% |
| Air chamber negative pressure | (-90~-120)Pa | 0.1Pa | Exceed±2.0% |
| operating temperature | (0~50)℃ | ||
| Negative pressure | (-50~-200)Pa | ||
| Data storage capacity | >100000 groups | ||
| Characteristics of High Efficiency Air Filter | The filtration efficiency of particles above 0.3um is ≥99.99% | ||
| Median mass diameter of aerosol generator | Mean Corpuscular Diameter(3.0±0.3)μm, geometric standard deviation≤1.5 | ||
| Dual channel 6 - stage Anderson sampler captures particle size | Ⅰclass>7μm,Ⅱclass(4.7~7)μm,Ⅲ class(3.3~4.7)μm,Ⅳclass(2.1~3.3)μm,Ⅴ class(1.1~2.1)μm,Ⅵclass(0.6~1.1)μm | ||
| Aerosol chamber specifications | (Length600×Dia85×Thickness 3)mm | ||
| Total number of particles in positive quality control sampler | (2200±500)cfu | ||