YC1893D Stationary Multi-Positions Three Phase Energy Meter Test Bench
YC1893D Stationary Multi-Positions Three Phase Energy Meter Test Bench
Our Advantages
Features& Functions
1. Install ICT in each meter position for testing three-phase meters with closed I-P links.
2. Measure mechanical, electronic mechanical, and electronic meters via automatic, semi-automatic, or manual operation.
3. Meters tested: 3P4W, 3P3W, 1P2W.
4. Testing modes: active power, reactive power, cross-connected reactive power.
5. Simultaneous measurement of meters with same specs but different constants.
6. Automatic rotor mark positioning on mechanical meter disc for higher efficiency.
7. Starting and creeping tests available.
8. Protection against overload, short-circuit voltage, and open-circuit current.
9. Synchronized scanning head movement for simplified control.
10. Made of lightweight, strong, and corrosion-resistant aluminum alloy.
11. Testing software compatible with Windows 2000/XP/7/8/10; includes modules for error, harmonic, demand, and influence tests.
Specifications
|
Technical spec. |
YC1893D-ICT-6 |
YC1893D-ICT-12 |
YC1893D-ICT-24 |
YC1893D-ICT-48 |
|
Number of meter positions equipped ICT |
6 |
12 |
24 |
48 |
|
Accuracy class of ICT |
0.05 / 0.01 |
|||
|
Accuracy |
0.05 |
|||
|
Power Source |
YCS-103-250 |
YCS-103-600 |
YCS-103-1200 |
YCS-103-2500 |
|
Standard Meter |
SZ03A-K6 / SZ03A-K8 (customized) |
|||
|
Scanning Head |
YCG-S Series |
|||
|
Voltage |
|
|||
|
Test voltage output(Phase-Neutral) |
3x(24V~288V)(or customized) |
|||
|
Power of the voltage output |
Max. 3x100VA |
Max. 3x250VA |
Max. 3x500VA |
Max. 3x1000VA |
|
Resolution |
Better than 0.01% of full scale value of range |
|||
|
Setting accuracy |
Better than 0.05% at the final range value |
|||
|
Stability |
Better than 0.005% /h (integration time 150s) |
|||
|
Load regulation from 0~max. load |
Better than 0.01% |
|||
|
Distortion factor |
Better than 0.3% for linear resistance load |
|||
|
Harmonic |
2nd~21st free programmable |
|||
|
Current |
|
|||
|
Test current output |
3x(1mA~100A) |
|||
|
Power of the current output |
Max. 3x150VA |
Max. 3x350VA |
Max. 3x750VA |
Max. 3x1500VA |
|
Resolution |
Better than 0.01% of full scale value of range |
|||
|
Setting accuracy |
Better than 0.05% at the final range value |
|||
|
Stability |
Better than 0.005% /h (integration time 150s) |
|||
|
Load regulation from 0~max. load |
Better than 0.01% |
|||
|
Distortion factor |
Better than 0.3% for linear resistance load |
|||
|
Harmonic |
2nd~21st free programmable |
|||
|
Phase angle |
|
|||
|
Range |
0~360⁰ |
|||
|
Resolution |
0.01⁰ |
|||
|
Setting accuracy |
0.1⁰ |
|||
|
Frequency |
|
|||
|
Range |
45Hz~65Hz |
|||
|
Resolution |
0.01Hz |
|||
|
Error display |
|
|||
|
Type of error display |
Red LED |
|||
|
Resolution of error displays |
8 digitals |
|||
|
Other |
|
|||
|
Voltage supply |
3x220/380V±10%(or customized) 50/60Hz ±2Hz |
|||
|
Ambient temperature |
-10°C~+40°C |
|||
|
Relative humidity |
35%~85% |
|||
Get in Touch