6KW Lithium Battery Forced Internal Short Circuit Tester PLC Control Customized
Battery Testing Equipment
Brand: HBYIQI
Equipment Name: Battery Forced Internal Short Circuit Tester
Standard basis: UL1642, GB 31241-2022
Application:
Battery forced internal short circuit tester simulates the short circuit caused by metal particles that may occur inside the battery during the production process, and evaluate the safety performance of the battery under such circumstances.
Technical Parameter
| Model |
HB-DC06-B-150L |
| Temperature Chamber | |
| Control Mode | PLC |
| Temperature range |
-10℃~+80℃(Adjustable) |
| Heating rate | Average 3℃/min (from -10℃ to 80℃, nonlinear no-load) |
| Cooling rate | Average 3℃/min (from 80℃ to -10℃, nonlinear no-load) |
| Inner box size | W500*D500*H600mm |
| Outer box size | W700*D900mm*H1800 |
| Inner box material | Mirror stainless steel plate, reinforced at bottom |
| Exterior box material |
Cold rolled steel paint treatment |
| Visual window |
The single door is equipped with a 3-layer vacuum large glass observation window (W270*H350mm); The door frame is equipped with electric heating (automatic adjustment) to prevent frost and condensation; So that you can observe the test status of the test sample in the box at any time through the observation window clearly. |
| Internal Short Circuit Standard | |
| Control mode | PLC |
| Maximum load | 200KG |
| Value resolution | 1/10000 |
| Force value accuracy | ≤0.5% |
| Displacement resolution | 1/1000 |
| Displacement accuracy | ≤0.5% |
| Speed range | 0.01-5mm/s |
| Limited travel | 0-200mm |
| Maximum test plane | 300x300mm (Special test width can also be customized according to customer requirements |
| Voltage collection range | 0-60V |
| Voltage resolution | 5mV |
| Voltage acquisition frequency | 100Hz |
| Input Power Requirement | |
| Work Voltage | AC 220V 50Hz or Customization Accepted |
| Power | 6KW |
| Optional Parts(Extra Charge) | |
| Addable item | Add temperature acquisition channel, voltage acquisition system, video surveillance system, smoke alarm system, fire extinguishing system(euipment provided by user). |
Safety protection design
- Pressure release vent: Automatic explosion-proof pressure relief device
- Smoke outlet: Get rid of the smoke
- Door opening induction switch: Open the door to restrict operation, to prevent misoperation and injury to employees, to maximize the protection of employee safety

- Explosion-proof chain: There are two explosion-proof chains on the left and right of the equipment door to prevent the door from being blown open at a critical time.

- Double-layer explosion-proof tempered glass: Protection is more secure.

- Explosion-proof mesh: Prevent battery explosion fragments from hitting the window.

Q1: What is your warranty ?
- 12 months product warranty. Free components will be provided if any performance failure occurs within 12 months caused by non-human damage.
Q2: What about the quality ?
- Each instruments must be carried out 100% quality examination and test when shipping and delivery goods.
- All of our machine are strictly according to CE & ISO standards.
Q3: How to get quotation?
- Leave your message and tell us your detail requirement, like test standard, test object, machine size, target price, etc...
- We provide 24-hour service online, and provide the quotation and solutions for you within 3 days.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.