Compact Hydraulic Power Unit Hydraulic Power Pack For Mobile Boarding Bridge
Price:
Negotiable
MOQ:
1 Piece
Delivery Time:
1-15 days
Brand:
Seric
Product Description
Compact Hydraulic Power Unit Hydraulic Power Pack For Mobile Boarding Bridge
Mobile Boarding Bridge Hydraulic Power Pack Hydraulic Power Unit
Features
- Compact-sized and lightweight power packages that use minimal oil delivered from a small tank
- High-performance gear pump installed
- Manifold block can be installed directly on the hydraulic pump as an option, making it easy to configure the hydraulic circuit of your choice by installing a small stack valve
- Full return line filter is standard equipment, enabling longer system life
- Variety of options available including temperature gauge, magnet, level switch, manifold block, and more
Technical Data
| Voltage Of Electric Motor | Power Of Electric Motor | Pump Displacement (ml/r) | Maximum Operating Pressure (Mpa) | Oil Tank Shape | Oil Tank Capacity (L) | Control Style | Mounting Style |
|---|---|---|---|---|---|---|---|
| AC: AC380V, AC220V, AC415V, AC450V, AC110V DC: DC12V, DC24V, DC36V, DC48V, DC60V, DC72V |
0.3KW~3KW | 0.75, 1, 2, 3, 3.5, 4.5, 5 | 31.5 | Cuboid, Cylinder | 2, 3, 4, 5, 6, 7, 8, 10, 12 | Manual operation, DC12V, DC24V, AC110V, AC220V | Horizontal, Vertical |

Operation and Maintenance Guidelines
Air Bleed
- During initial system startup (and startups after long period of storage), pump may have difficulty drawing fluid
- By pre-installing an air bleed valve (ABT-03) or by loosening a fitting in the delivery pipe, air can be bled from the system
- During air bleed of pump and piping, pump should be run at no load
Warm Up
- During startup, if viscosity is higher than proper viscosity (54 mm²/s), system should be warmed up with pressure less than half of maximum working pressure until viscosity falls below 54 mm²/s
Hydraulic Fluids
- Maximum operating pressures, maximum speeds, and other specifications may differ according to the hydraulic fluid used
Mineral Oils
- Please use general industrial use anti-wear fluids
Fire Resistant Fluids
- Water glycols may be used with standard type pumps, however maximum operating pressures, maximum speeds, and other specifications will differ from those of mineral oil fluids
- Fluorine seals are used with pumps that operate on phosphate ester fluids (designated with "F3-" suffix), however specifications for maximum operating pressures, maximum speeds, etc., will differ from those of mineral oil fluids
Hydraulic Fluid Viscosity and Temperature
- Please operate pump with viscosity level within 13~54 mm²/s range
- Maximum viscosity allowed is 860 mm²/s (220 mm²/s for V20, V30 Series), but warm up and operation should be done in accordance with the "Warm Up" guidelines
- Fluid temperature should be maintained below 65°C
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Guangzhou Seric Hydraulic Co., Ltd.
Location
Room 211, No. 9, Wanyu Street , Huangpu District, Guangzhou City
Contact Person
Shen