Fire Alarm System
Office Building Addressable Zone Monitoring Module Connecting Up To 16 Conventional Detector
Addressable Zone Monitoring Module for T&A 3 Series Intelligent Fire Alarm System TX3217 Addressable Zone Monitoring Module Main Features: Non-polarized two-wire bus Built-in microprocessor Electronic address coding Intelligent self-diagnosis of open circuit Enhanced capacity of interference resistance by multilevel wave filtering process Parallel connecting up to 16 conventional detector with current <100μA per detector Technical Specifications Operating Voltage: 15~28VDC
Addressable Fire Alarm System Components Loop Isolator for Short Circuit Protection
Addressable Loop Isolator for T&A 3 Series Intelligent Fire Alarm System TX3219 Loop Isolator Main Features: Non-polarized input/output signal Isolated devices can be re-connected to system automatically after fault is fixed 100mA/200mA output current optional Technical Specifications Operating Voltage: 18-28VDC, 24VDC recommended Operating Current: K open≤100mA, K short≥200mA Loading Capacity: K open: loop 24V, 100mA; K short : loop 24V, 200mA, LED Indicator Status: Monitor:
Addressable Fire Alarm System Intelligent Sounder Strobe DC 24V EN54-3 Standard
Intelligent Sounder Strobe in compliance with EN54-3 standard TX7300 Intelligent Sounder Strobe Main Features Design in compliance with EN 54-3 standards. Selectable 16 tones output. Strobe with high intensity LED cluster, long lifespan Loop powered or external 24V powered. Power-saving & normal consumption mode Single/dual electronic addresses coding. 3 working modes: sounder & strobe / strobe only / sounder only. Technical Specifications Operating Voltage: Loop: 24V (16V
Addressable Sounder Strobe With High Intensity LED Cluster And High Sound Pressure Level
Addressable Sounder Strobe with high intensity LED cluster and high sound pressure level TX3301 Addressable Sounder Strobe Main Features: Optional loop powered or external PSU powered Strobe with high intensity LED cluster, long lifespan Low power consumption Electronic address coding Integrated structure design for high reliability and easy installation Technical Specifications: Operating Voltage: Bus Voltage: 24VDC (15~28VDC) Power Supply: 24VDC (20~28VDC) Operating Current
Addressable MCP Manual Call Point with Resettable Non-breaking Glass and Fire Telephone Jack
Addressable MCP with resettable non-breaking glass and fire telephone jack TX3140 Addressable Manual Call Point Main Features: Electronic address coding Resettable non-breaking glass, with telephone jack Enhanced capacity of interference resistance by multilevel wave filtering process Directly control other periphery devices via its independent output contact Fully-sealed protection process for PCB board. Plug-in structural design for easy and reliable installation Technical
Intelligent Manual Call Point for Fire Alarm Systems with Non-breaking Resettable Glass
EN54 Standard Intelligent Manual Call Point with resettable non-breaking glass TX7140 Intelligent Manual Call Point Main Features Design in compliance with EN 54-11 standards Electronic address coding Built-in microprocessor processes messages intelligently. Resettable non-breaking glass Plug-in structural design for easy and reliable installation Technical Specifications Operating Voltage : 24VDC(16V~28V) Operating Current : Standby Current ≤0.6mA; Alarm current ≤1.1mA LED
24VDC Fire Alarm System Intelligent Photoelectric Smoke Detector with Remote Indicator Output
EN54-7 Standard Intelligent Photoelectric Smoke Detector with remote indicator output TX7100 Intelligent Smoke Detector Main Features Design in compliance with EN 54-7 standards Electronic address coding Enhanced detector’s reliability by automatic data drift compensation function Self-diagnostic function for inner fault. 360 viewable LED indicator 10 historic data records. Remote indicator output. Technical Specifications Operating Voltage: 24VDC (16V~28V) Operating Current:
Loop Wiring Fire Alarm System Fire Repeater Panel for Fire Detection Systems
Fire Repeater Panel for T&A 3-series intelligent fire alarm system TX3403E Fire Repeater Panel Main Features: Back lit LED displaying all the information Display Capacity: Max 1024 pieces of the scrolling information Simultaneous audible and visual alarm with the control panel Loop wiring, every loop with max 32 repeater panels Technical Specifications Operating Voltage: Bus Voltage: 24VDC (15~28VDC) Power Supply: 24VDC (20~28VDC) Operating Current: Loop monitoring current:
2 - Loop 484 Points Intelligent fire Alarm Control Panel X3002E , Wall Mounted
2-Loop 484 Points Intelligent fire Alarm Control Panel TX3002E Intelligent Fire Alarm Control Panel Main Features Wall mounted 2-loop panel with capacity of max. 484 addressable devices Simple and effective user interface with a large 7” TFT LCD display CAN bus networkable with all T&A 3-series intelligent fire panels Flash memory retains all programming and events data even the panel’s power is down Built-in printer and RS232 /RS485/CAN network cards Auto-monitoring and
1 - Loop 242 Points Fire Alarm System TX3000E Intelligent Fire Alarm Control Panel
1-Loop 242 Points Intelligent fire Alarm Control Panel TX3000E Intelligent Fire Alarm Control Panel Main Features Wall mounted single loop panel with capacity of max. 242 addressable devices Simple and effective user interface with a 128mm * 64mm LCD display CAN bus networkable with all 3-series T&A intelligent fire panels Flash memory retains all programming and events data even the panel’s power is down Built-in printer and RS232 /RS485/CAN network cards Auto-monitoring and