UL Curly Cable
UL21782 Electric Equipment Extendable Curly Cable
UL21782 Electric Equipment Extendable Curly Cable Curly cable style: UL21782 Rated: 90°C, 600V. Insulation Material: Thermoplastic TPU. Jacket Material: Thermoplastic TPU. Feature: highly elastic, best for connection under limit space. Extended Distance: cable diameter x 3.5~4. Executed Standard: UL1581, UL758. Application: Electric equipment interconnection. Specification Parameters: Curly Style Conductor Quantity Conductor Size Conductor Strands Insulation Thickness
UL21768 Electric Equipment Extendable Curly Cable
UL21768 Electric Equipment Extendable Curly Cable Curly cable style: UL21768 Rated: 105°C, 600V. Insulation Material: Thermoplastic TPU. Jacket Material: Thermoplastic TPU. Feature: highly elastic, best for connection under limit space. Extended Distance: cable diameter x 3.5~4. Executed Standard: UL1581, UL758. Application: Electric equipment interconnection. Specification Parameters: Curly Style Conductor Quantity Conductor Size Conductor Strands Insulation Thickness
UL21767 Electric Equipment Extendable Curly Cable
UL21767 Electric Equipment Extendable Curly Cable Curly cable style: UL21767 Rated: 105°C, 600V. Insulation Material: Thermoplastic TPU. Jacket Material: Thermoplastic TPU. Feature: highly elastic, best for connection under limit space. Extended Distance: cable diameter x 3.5~4. Executed Standard: UL1581, UL758. Application: Electric equipment interconnection. Curly Style Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket
UL21573 Electric Equipment Extendable Curly Cable
UL21573 Electric Equipment Extendable Curly Cable Curly cable style: UL21573 Rated: 80°C, 600V. Insulation Material: Thermoplastic TPU. Jacket Material: Thermoplastic TPU. Feature: highly elastic, best for connection under limit space. Extended Distance: cable diameter x 3.5~4. Executed Standard: UL1581, UL758. Application: Electric equipment interconnection. Curly Style Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket
UL22031 Electric Equipment Extendable Curly Cable
UL22031 Electric Equipment Extendable Curly Cable Curly cable style: UL22031 Rated: 80°C, 300V. Insulation Material: Thermoplastic TPU. Jacket Material: Thermoplastic TPU. Feature: highly elastic, best for connection under limit space. Extended Distance: cable diameter x 3.5~4. Executed Standard: UL1581, UL758. Application: Electric equipment interconnection. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket
UL21781 Electric Equipment Extendable Curly Cable
UL21781 Electric Equipment Extendable Curly Cable Curly cable style: UL21781 Rated: 90°C, 300V. Insulation Material: Thermoplastic TPU. Jacket Material: Thermoplastic TPU. Feature: highly elastic, best for connection under limit space. Extended Distance: cable diameter x 3.5~4. Executed Standard: UL1581, UL758. Application: Electric equipment interconnection. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket
UL21766 Electric Equipment Extendable Curly Cable
UL21766 Electric Equipment Extendable Curly Cable Curly cable style: UL21766 Rated: 105°C, 300V. Insulation Material: Thermoplastic TPU. Jacket Material: Thermoplastic TPU. Feature: highly elastic, best for connection under limit space. Extended Distance: cable diameter x 3.5~4. Executed Standard: UL1581, UL758. Application: Electric equipment interconnection. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket
UL21765 Electric Equipment Extendable Curly Cable
UL21765 Electric Equipment Extendable Curly Cable Curly cable style: UL21765 Rated: 105°C, 300V. Insulation Material: Thermoplastic TPU. Jacket Material: Thermoplastic TPU. Feature: highly elastic, best for connection under limit space. Extended Distance: cable diameter x 3.5~4. Executed Standard: UL1581, UL758. Application: Electric equipment interconnection. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket
UL21007 Electric Cabinet Curly Cable
UL21007 Electric Cabinet Curly Cable Rating: 60 deg C, 30 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: Thermoplastic TPU. Executed Standard: AWM. Application: electric cabinet connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21007 3C 28 7/0.127 0.23
UL21314 Oxygen Equipment Curly Cable
UL21314 Oxygen Equipment Curly Cable Rating: 60 deg C, 90 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: Polyurethane PUR. Executed Standard: AWM. Application: oxygen equipment connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21314 3C 28 7/0.127 0.23 0
UL20963 Electrical Equipment Curly Cable
UL20963 Electrical Equipment Curly Cable Rating: 80 deg C, 30 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: Thermoplastic TPU. Executed Standard: AWM. Application: electrical equipment connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL20963 3C 28 7/0
UL21687 Scanned Equipment Curly Cable
UL21687 Scanned Equipment Curly Cable Rating: 80 deg C, 30 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: Polyurethane PUR. Executed Standard: AWM. Application: scanned equipment connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21687 3C 28 7/0.127 0.23
UL21165 Motion Device Curly Cable
UL21165 Motion Device Curly Cable Rating: 80 deg C, 300 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: Thermoplastic TPU. Executed Standard: AWM. Application: motion device connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21165 3C 28 7/0.127 0.23 0.90
UL21161 Scooter Curly Cable
UL21161 Scooter Curly Cable Rating: 80 deg C Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: Thermoplastic TPU. Executed Standard: AWM. Application: scooter connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21161 3C 28 7/0.127 0.23 0.90 0.76 3.96 239.00 3C
UL21142 Medical Handspring Curly Cable
UL21142 Medical Handspring Curly Cable Rating: 60 deg C, 30 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: Thermoplastic TPU. Executed Standard: AWM. Application: medical handspring connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21142 3C 28 7/0.127 0
UL21126 Electrical Appliance Curly Cable
UL21126 Electrical Appliance Curly Cable Rating: 80 deg C, 30 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: Thermoplastic TPU. Executed Standard: AWM. Application: electrical appliance connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21126 3C 28 7/0
UL21330 Pneumonia Tester Curly Cable
UL21330 Pneumonia Tester Curly Cable Rating: 80 deg C, 1000 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: polyurethane PUR. Executed Standard: AWM. Application: pneumonia tester connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21330 3C 28 7/0.127 0.76
UL21294 Motor Engineered Curly Cable
UL21294 Motor Engineered Curly Cable Rating: 80 deg C, 600 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: polyurethane PUR. Executed Standard: AWM. Application: motor connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21294 3C 28 7/0.127 0.76 2.00 0.381
UL21238 Electric Car Curly Cable
UL21238 Electric Car Curly Cable Rating: 80 deg C, 600 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: polyurethane PUR. Executed Standard: AWM. Application: electric car connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21238 3C 28 7/0.127 0.76 2.00 0
UL21223 POS Device Curly Cable
UL21223 POS Device Curly Cable Rating: 80 deg C, 600/1000 Vac Conductor Size: 10-32AWG Conductor Quantity: 2 ~ 50 cores Insulation Material: Polypropylene PP Jacket Material: thermoplastic TPU. Executed Standard: AWM. Application: POS device connect purpose. Style Number Conductor Quantity Conductor Size Conductor Strands Insulation Thickness Insulation Diameter Jacket Thickness Overall Diameter Conductor Resistance AWG No/mm mm mm mm mm Ω/KM UL21223 3C 28 7/0.127 0.76 2.00 0