Portable Energy Meter Test Equipment
Portable 3 Position 3 PHA Energy Meter Test Bench(WC 3P Kwh Meter)
HS3303 Three Phase Energy Meter Test Bench 1.with Three-phase Standard Energy Meter 2.Can hung with 1-3 position. 4.Accuracy: 0.05% & 0.1% Class Technical Paramenters 1. Output voltage and currentdistortion: not larger than 0.3%(if it is a linear load) 2. OutputPower Stability: The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range 3. Number ofharmonic wave: 2-31 Content of harmonic wave:less than 40%(compared with basewave
Portable Three Phase Static Meter Test Instrument(Electric Energy)
HS3303 Three Phase Portable Energy Meter Test Bench 1.Inserted with Poly-phase Standard Energy Meter 2.Inserted with Error Processor 3.Can hung with 1-3 position. 4.Accuracy: 0.1% Class Technical Paramenters 1. Output voltage and currentdistortion: not larger than 0.3%(if it is a linear load) 2. OutputPower Stability: The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range 3. Number ofharmonic wave: 2-31 Content of harmonic
HS-3303 Portable Three Phase Electric Meter Test Bench(Measurement Instrument)
HS3303 Three Phase Portable Energy Meter Test Bench 1.Inserted with Poly-phase Standard Energy Meter 2.Inserted with Error Processor 3.Can hung with 1-3 position. 4.Accuracy: 0.1% Class Technical Paramenters 1. Output voltage and currentdistortion: not larger than 0.3%(if it is a linear load) 2. OutputPower Stability: The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range 3. Number ofharmonic wave: 2-31 Content of harmonic
HS-3103 Portable Static Meter Test Equipment(Single Phase Electric Energy)
HS-3103 Portable Single Phase Energy Meter Test Bench Output voltage and current distortion not larger than 0.3%(if it is a linear load) The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range Number of harmonic wave: 2-31 Content of harmonic wave: less than 40%(compared with basewave) Phase of harmonic wave: 0°-359.99° Reading will be made directly from the standard watt-hour meter AC single-phase 220/240(110V also
HS-3103 1 Position Portable Single Phase Meter Test Equipment
HS-3103 1 Position Portable Single Phase Meter Test Equipment Suit for Lab Output voltage and current distortion not larger than 0.3%(if it is a linear load) The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range Number of harmonic wave: 2-31 Content of harmonic wave: less than 40%(compared with basewave) Phase of harmonic wave: 0°-359.99° Reading will be made directly from the standard watt-hour meter AC single-phase 220
HS3103 Portable Meter Test Equipment(Electric Energy)
HS3103 Portable 1 Phase Energy Meter Test Equipment Technical specification 1. Electrical output 1) Voltage and current measurement range Output voltage ranges: 57.7V/63.5V and 220V/240V (480V option) Output current ranges: 0.1A, 1A, 5A, 20A, and 100A 2) Output load capacity Voltage loop: Max. 50VA Current loop: Max 100VA (Measurement range 100A) 2. Electrical output adjustment 1) Voltage adjustment a) Adjustment range: 0%~125% selected voltage range b) Adjustment fineness:
Portable Single Phase Energy Meter Tester (on-site)
HS-3103 Portable Single Phase Energy Meter Test Bench Output voltage and current distortion not larger than 0.3%(if it is a linear load) The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range Number of harmonic wave: 2-31 Content of harmonic wave: less than 40%(compared with basewave) Phase of harmonic wave: 0°-359.99° Reading will be made directly from the standard watt-hour meter AC single-phase 220/240(110V also
HS3303 Three Phase Portable Static Meter Test Bench(Electricity Meter Test)
HS3303 Portable 3 Phase Energy Meter Test Bench Technical specification 1. Electrical output 1) Voltage and current measurement range Output voltage ranges: 57.7V/63.5V and 220V/240V (480V option) Output current ranges: 0.1A, 1A, 5A, 20A, and 100A 2) Output load capacity Voltage loop: Max. 50VA Current loop: Max 100VA (Measurement range 100A) 2. Electrical output adjustment 1) Voltage adjustment a) Adjustment range: 0%~125% selected voltage range b) Adjustment fineness: four
HS3303 Three Phase Energy Meter Testing Equipment(Electrical Meter Testing Equipment)
HS3303 Three Phase Energy Meter Test Bench 1.with Three-phase Standard Energy Meter 2.Can hung with 1-3 position. 4.Accuracy: 0.05% & 0.1% Class Technical Paramenters 1. Output voltage and currentdistortion: not larger than 0.3%(if it is a linear load) 2. OutputPower Stability: The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range 3. Number ofharmonic wave: 2-31 Content of harmonic wave:less than 40%(compared with basewave