Plug Socket Tester
SN441011-2-3:2019-Lehre C2 Swiss Plug Gauge
SN441011-2-3:2019-Lehre C2 Swiss Plug Gauge
SN441011-2-3:2019-Lehre C1 Swiss Plug Gauge
SN441011-2-3:2019-Lehre C1 Swiss Plug Gauge
IEC 60309 Gauges ,IEC 60309 Gauge for Plug & Pin List
IEC 60309-2 Gauge Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories IEC 60309-2-Fig.101-16/20A, 32/30A, 63/6A and 125/100A socket-outlets and connectors having rated operating voltages exceeding 50V- "Go" gauges for checking demensions d1, d2, l1 IEC 60309-2-Fig.102-16/20A, 32/30A, 63/6A and 125/100A socket-outlets and connectors having rated operating voltages exceeding 50V-
IEC60309-1-Plugs , Socket-Outlets And Couplers For Industrial Purposes
IEC60309-1-Plugs, Socket-Outlets And Couplers For Industrial Purposes -- Part 1: General Requirements Fig. 13
Gauge For Base G9
"Go" Gauge For Base G9, Cód. 7006-129-1
6:100 Luer Gauge
6:100 Luer Gauge 6:100 luer taper joint gauge to meet the GB/T1962.1 - 2001 the syringe, needles and other medical equipment 6% (Luer) cone joint design, manufacturing, the gauge the relevant technical requirements. The joint is connected with inner and outer taper connecting pipe is Ruhr invented is called luer taper C= (D big diameter -d small end diameter (/L) of L is D to D range). Cone joint 6:100, is when the length = 100, big diameter - small end diameter =6. Luer
DIN-VDE0620-1 Plug and Socket Gauge
DIN-VDE0620-1 Plug and Socket Gauge Figure number Project name Number DIN-VDE0620-1-Lehre1 Socket R gauge (5.0,5.8,6.0) 3 DIN-VDE0620-1-lehre2 Minimum opening width and minimum pull out force of contact jack 2 DIN-VDE0620-1-Lehre3 Bipolar plug force 1 DIN-VDE0620-1-Lehre4 Bipolar plug with earthing contact insertion flanking force 1 DIN-VDE0620-1-Lehre5 To test the first time contact closure interval gauge 1 sets of /4 parts DIN-VDE0620-1-Lehre6 Pin diameter 1 sets of /4
EN 60320 gauge Figure 9K
EN 60320 gauge Figure 9K
IEC60320-1 Clause 16 Figure Switch Tester
IEC60320-1 Clause 16 Figure 12 Coupler Withdrawal Testing Apparatus in Hot Conditions Product Information: This testing apparatus confirms to the IEC60320-1, clause 16 figure 12 standard requirement. The construction of appliance couplers shall allow the easy insertion and withdrawal of the connector, and prevent the connector from working out of the appliance inlet in normal use. This device is mainly used to ascertain the maximum force necessary to withdraw the connector
IEC60320-1 Switch Tester Coupler Lateral Pulling Test Machine
Coupler Lateral Pulling Testing Apparatus Product Information: This device is according to the IEC60320-1, figure 19 standard requirement to design. It is used for the testing of withdrawing appliance inlet under the conditions of the connector with force, for this reason to test the mechanical strength of the connector. Technical Parameters: 1, Flexible cable bending height: 40±2 mm, adjustable. 2, Pull range: 0-100N. 3, Pull way: Manual operation,50 times in one direction
IEC60320-1 Coupler Heating Device
IEC60320-1 Clause 18.2 Figure 13 Coupler Heating Device Product Information: This device is designed according to the IEC60320-1,clause 18.2 figure 13 standard requirements . It is used for testing the heat resistance of coupler in hot conditions and very hot conditions, this device adopts temperature control, precise display and durable. Technical Parameters: Model No. TR-4 Standard IEC60320-1 clause 18.2 and figure 13 Power Supply AC120V, 50Hz or AC220V, 60HZ Coupler inlets
Switch Tester Coupling Implement Shell Pressure Test Device
40N ± 2N Switch Tester Coupling Implement Shell Pressure Test Device Product Information: This device is according to the IEC60320-1 standard requirement to design. Appliance inlets designed for surface mounting and having a shroud of metal, are compressed in an appropriate test apparatus, an example of which is shown in figure 20. The spherical end of the jaws shall have a radius of 20mm±1mm. A force of 40N±2N shall be applied for 60s±6s through the jaws to the most
Coupler Connector Gauge Testing Equipment For Laboratory IEC60320.1
Coupler Gauge Testing Equipment For Laboratory and Measurement Testing Departments Product Information: This coupler gauge confirms to the IEC60320.1 standard, it is used for the purpose of verifying coupler sizes and interchangeability measurement of the household and similar appliances, it is a necessary testing equipment for laboratory and measurement testing departments. Technical Parameters: No. Item Figure No. QTY. Remark 1 C1 GO gauge Figure 2 1 Check the connector 2
IEC60884 Figure 9-Gauge for checking non-accessibility of live parts, through shutters
20N gauge / IEC60884 Figure 9-Gauge for checking non-accessibility of live parts, through shutters Description: Gauge for checking non-accessibility of live parts, through shutters. The gauge is applied to the shutters in the most unfavourable position, successively in three directions, to the same place for approximately 5s in each of the three directions. Specifications: Item 20N gauge Refer standard IEC 60884 Figure 9 Size 1*3mm Length 80mm Handle Diameter 30mm, length
Plug Breaking Capacity Test Equipment 5A / 250VAC 50 / 60Hz 300W
Chapter one: introduction of the instrument 1.1 Characters and main use This machine is applied to test the breaking capacity of plug and receptacle, that is the same with the life-span of insert and withdraw testing. This apparatus can work together with a load machine to perform load test. You can form a closed-loop load power test system with our company's load machine to perform the simulated aging power test with plug and socket at the full load. This apparatus has a
Device For Checking The Resistance To Lateral Strain , IEC 60884-1 Test Equipment
IEC60884clause 12.14 testing equipment of Lateral Strain for socket-outlets with 5N weight Standard: IEC 60884-1 2013 clause 13.14 figure 13 Application: This device is use to check whether any damage to the socket-outlets ratings up to 16A and 250V when a inserted appliance applying a lateral strain to it. Test sample: Socket-outlets Feature: Made according to standard dimension requirements, use to check the mechanical strength of socket hole Parameters: sets of test plug,
As/Nzs 3112 Abrasion Test Apparatus For Insulation On Insulated Pin Plugs
AS/NZS 3112 ABRASION TEST APPARATUS FOR INSULATION ON INSULATED PIN PLUGS Standard: IEC 60884-1- figure 28, BS1363-1 figure 9, EN50075, AS/NZ3112 Application: This device is use for test the abrasion resistance strength of insulation sleeve of plug pins Test sample: Insulation Sleeve of plug pins Feature: Device consists of a horizontal placement of the beam and the linear movement of the fixture seat, wherein, beam ends with diameter 1mm short steel wire is bent into a U
SN 441011-2-3:2019 Lehre J1 Gauge For Suisse Plugs
SN 441011-2-3:2019 Lehre J1 Gauge for suisse plugs Material:Stainless steel Packing:
CEE7 Plug Socket Tester Plug And Socket Gauge Calibration Certificate
CEE7 Plug Socket Tester , Plug And Socket Gauge Calibration Certificate NO Figure No. Description 1 CEE7/C1 10/16A 250V two-pole socket-outlets Gauges c1 for size of entry holes for plug pins 2 CEE7/C2A.B 10/16A 250V two-pole socket-outlets and two-pole plugs with pin-type earthing-contact Gauges c2 for minimum opening of contact tubes 3 CEE7/C3 10/16A 250V two-pole socket-outlets Gauge c3 for acceptance of two-pole plugs 4 CEE7/C4 10/16A 250V two-pole socket-outlets with