Industrial Flexible Cable
UL1674 Solid / Stranded Single Conductor Cable PVC Single Core
UL1674 Solid / Stranded Single Conductor Cable, PVC Single Core Flexible Cable Product Description Construction Conductor : Solid or Stranded Insulation: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300V Rated Temperature: -40~105ºC Flame: VW-1, FT1, FT2 Oil resistance: 60 ºC or 80 ºC Oil Voltage withstand test:AC 2.0kV/1mi Printing :E258652 AWM STYLE 10198 AWGXX 105ºC 300V VW-1 ---c AWM I A/B 105ºC 300V FT1 -LF-HWATEK
UL2464 Electrical Flexible Cable PVC Insulated With Copper Conductor
UL2464 PVC Insulated Flexible Electrical Power And Control Stranded Electric Copper Wire Cable Wire Product Description Construction Conductor : stranded, tinned or bare copper Insulation: PVC,SRPVC, black cores with continuous white numbering (also available in other colours on request) GN-YE conductor, 3 cores and above in the outer layer Shield or Braid: bare or tinned copper braid or Spiral and AL-mylar Jacket: PVC Application These cables are appropriate for flexible use
UL2586 PE Braided Electrical DC Cable Wire Multi Strand
UL2586 PE Braided Multistrand Electrical Winding Motor Energy Electric DC Cable Wire Product Description Construction Conductor : stranded, tinned or bare copper, IEC60228 CL5 Insulation: Special PVC, SRPVC, PP Jacket: PVC Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:600V Rated Temperature:-40ºC-105ºC Flame: VW-1, FT1, FT2 Oil resistance: 60 ºC or 80 ºC Oil Voltage withstand test:AC 2.5kV/1min Printing :E258652 AWM STYLE
UV Resistant Industrial Flexible Cable XLPE Insulated Electrical
UL XLPE Insulated PVC Flexible Multi Tinned Copper Conductor Electric Electrical Lighting Wire And Cable Product Description Construction Conductor : stranded, tinned or bare copper Insulation: PP, TPEE Shield or Braid: bare or tinned copper braid or Spiral and AL-mylar Jacket:PUR Standards International:UL758 AWM STYLE 20940,UL1581, UL2556, IEC60228 CL5 RoHS,REACH Compliant, Technical data Rated voltage:1000V Rated Temperature:-40ºC-80ºC Flame: VW-1, FT1, FT2,IEC60332-1-3
Electric Industrial Flexible Cable PVC Insulated Single Core Bare Copper
PVC Insulated Single Core Industrial Flexible PVC Bare Copper Electric Electrical Wire Cable China Factory Product Description Construction Conductor : stranded, tinned or bare copper, IEC60228 CL5 Insulation:PUR Standards International: UL758 , UL1581, UL2556 RoHS,REACH Compliant, Technical data Rated voltage:300 V Rated Temperature:-40~80ºC Flame: VW-1, FT1, FT2 Oil resistance: 60 ºC or 80 ºC Oil Voltage withstand test:AC 2.5kV/1min Minimum bending radius flexing 10x cable
UL Single Core Industrial Flexible Cable PVC Insulated For Drag Chain Wiring
UL Single Core PVC Insulated Flexible Copper Drag Chain Electrical Electric Power Wire Cable Manufacturer Product Description Products are used in engineering machinery, machine processing equipment, logistics delivery system, lifting etc. Application: drag chain wiring Application standard: GB 5023.3-2008 Product character: Standard thickness,easily strip and cut Tiny conductor diameter has high flexibility Oil and heat resistance, anti-bending and abrasion Constructure:
Halogen Free PU Jacket Multi Core Copper Cable 600V 1000V
Halogen Free PU Jacket Multi-Core Copper Wires Application: For wiring of sensor Product character: Oil and Heat resistance, anti-abrasion, halogen free Pass UL VW-1 and CSA FT1 vertical flame test Constructure: Tinned or bare, stranded or single copper conductor, PE or PP insulation Two or more single-core wire are twisted and cabling Spiral or braiding shield with tinned or bare copper or Al-mylar wrapped shield PU jacket (halogen free material optional) Technical parameter
Frpe Jacket Multi Core Hook Up Wire Cable Anti Abrasion
Frpe Jacket Multi Core Hook Up Wire Cable Product character: Oil and Heat resistance,anti-abrasion, halogen free Pass UL VW-1 and CSA FT1 vertical flame test Application: For internal wiring of sensor Application standard: UL758, UL1581 UL number: UL20855, UL21100, UL21118 Constructure: Tinned or bare, stranded or single copper conductor, PE or PP insulation Two or more single-core wire are twisted and cabling Spiral or braiding shield with tinned or bare copper or Al-mylar
PE PP Insulation Braided Electrical Cable High Voltage
Braided Electrical High Voltage Cable Wire Application: Internal wring or external interconnection of electronic equipment. Application standard: UL758&UL1581&CSA C22.2 No.210 Product character: Excellent insulation performance, stable chemical properties, Heat resistance, anti-acid, environmental protection etc. Pass UL VW-1 and CSA FT1 vertical flame test Thin thickness of insulation, Halogen free, High-voltage resistance Constructure: Tinned or bare copper, stranded or
Hook Up XLPE Insulated Wire Industrial Control UL21410
UL21410 Hook Up XLPE Insulated Wire Cable Application: Internal wring or external interconnection of electronic equipment. Application standard: UL758&UL1581&CSA C22.2 No.210 Product character: Excellent insulation performance, stable chemical properties Pass UL VW-1 and CSA FT1 vertical flame test High-temperature resistance, anti-acid, environmental protection etc. Constructure: Tinned or bare copper, stranded or single conductor PVC ,PE, XLPE insulation Two or more single
XLPE Jacket Braided Copper Wire PVC Insulation UL21411
UL21411 Braided Copper Wire Application: Internal wring or external interconnection of electronic equipment. Application standard: UL758&UL1581&CSA C22.2 No.210 Product character: Excellent insulation performance, stable chemical properties Pass UL VW-1 and CSA FT1 vertical flame test High-temperature resistance, anti-acid, environmental protection etc. Constructure: Tinned or bare copper, stranded or single conductor PVC ,PE, XLPE insulation Two or more single-core wires is
300V XLPE Insulated Cable Tinned Copper Industrial UL21414
UL21414 XLPE Insulated Cable Application: Internal wring or external interconnection of electronic equipment. Application standard: UL758&UL1581&CSA C22.2 No.210 Product character: Excellent insulation performance, stable chemical properties Pass UL VW-1 and CSA FT1 vertical flame test High-temperature resistance, anti-acid, environmental protection etc. Constructure: Tinned or bare copper, stranded or single conductor PVC ,PE, XLPE insulation Two or more single-core wires is
XLPE Jacket Industrial Control Cable 300V 600V UL21521
UL21521 Industrial Control Wire Cable Factory Application: For internal or external interconnection of electronic equipment. Application standard: UL758&UL1581&CSA C22.2 No.210 Product character: Excellent insulation performance, stable chemical properties Pass UL VW-1 and CSA FT1 vertical flame test High-temperature resistance, anti-acid, environmental protection etc. Constructure: Tinned or bare copper, stranded or single conductor, 26-16AWG PVC ,PE, XLPE insulation Two or
UL21089 Electrical Hook Up Wire And Cable 30V Tinned
UL Electrical Hook Up Wire And Cable Application: Internal wring or external interconnection of electronic equipment. Application standard: UL758&UL1581&CSA C22.2 No.210 Product character: Excellent insulation performance, stable chemical properties Pass UL VW-1 and CSA FT1 vertical flame test Heat resistance, anti-acid and environmental protection etc. Constructure: Tinned or bare copper, stranded or single conductor, 30-4/0AWG PE or PP insulation Two or more single-core
UL21089 Industrial Electrical Hook Up Cable With FRPE Jacket
UL21089 Electrical Hook Up Wire And Cable roduct Number Conductor Insulation Shield Jacket Max. Cond. Resistance (200C) Ω/km core Size AWG NO./mm Conductor Dia . mm Nom. Thickness mm Nom. Dia. mm m/n/d Nom. Thick. mm Nom. Dia. mm HT21089**001 10C 28 7/0.127 0.38 0.20 0.78 16/6/0.12 0.65 5.10 223 HT21089**002 10P 28 7/0.127 0.38 0.20 0.78 16/8/0.12 0.70 6.60 223 HT21089**003 8C 28 7/0.127 0.38 0.20 0.78 16/6/0.12 0.60 4.60 223 HT21089**004 6P 28 7/0.127 0.38 0.20 0.78 16/7/0
Industrial Control Braided Hook Up Wire Cable With PU Jacket UL20940
UL20940 Industrial Control Braided Hook-Up Wire Cable Application: For internal wiring of electronic equipment and appliance. Application standard: UL758&UL1581&CSA C22.2 No.210 Product character: Excellent insulation performance, stable chemical properties Pass UL VW-1 and CSA FT1 vertical flame test Heat resistance, anti-acid and environmental protection etc. Constructure: Tinned or bare copper, stranded or single conductor, 32-4/0AWG PVC, SR-PVC, PE or PP insulation. Two
PU Jacket Electric Hook Up Wire UL 20549 With Tinned Copper
UL 20549 Electric Hook Up Wire Application: For internal wiring of electronic equipment Application standard: UL758&UL1581&CSA C22.2 No.210 Product character: Excellent insulation performance, stable chemical properties Pass UL VW-1 and CSA FT1 vertical flame test Heat resistance, anti-acid and environmental protection etc. Constructure: Tinned or bare copper, stranded or single conductor, 32-4/0AWG PVC, SR-PVC, PE or PP insulation. Two or more single-core wires are twisted
UL2517 Twisted Shielding Industrial Flexible Cable Multi Pairs ETFE Insulation
UL2517 Multi-Pairs Twisted Shielding Industrial Robot Cable Product Number Conductor Insulation Shield Jacket Max. Cond. Resistance (200C) Ω/km Cores Size AWG NO./mm Conductor Dia . mm Nom. Thickness mm Nom. Dia. mm Material Nom. Thickness mm Nom. Dia. mm HT2517***001 3P 28 16/0.08 0.38 0.20 0.81 TC 0.80 5.30 140 HT2517***002 8P 28 16/0.08 0.38 0.20 0.81 0.80 7.30 140 HT2517***003 3P 24 43/0.08 0.60 0.20 1.01 0.80 6.00 223 HT2517***004 8P 24 43/0.08 0.60 0.20 1.01 0.80 8.50
Signal Robot Cable Used In Long Distance Drag Chain Oil Resistance
Long Distance Using Signal Robot Cable Products are used in long distance drag chain Product Number Conductor Insulation Shield Jacket Max. Cond. Resistance (200C) Ω/km Cores Size AWG NO./mm Conductor Dia . mm Thickness mm Nom. Dia. mm Material Nom. Thickness mm Nom. Dia. mm HTR***013 4C 19 7/22/0.08 0.24 0.40 2.1 / 1.0 7.2 4C 8C HTR***014 8C 11.5 HTR***016 4C 17 7/36/0.08 0.38 0.40 2.45 8.1 4C HTR***017 8C 12.1 Application: Long distance drag chain cable Application standard
Shielded Signal PVC Jacket Robot Cable 300V Long Distance Using
Long Distance Using Shielded Signal Robot Cable Product Number Conductor Insulation Shield Jacket Max. Cond. Resistance (200C) Ω/km Cores Size AWG NO./mm Conductor Dia . mm Thickness mm Nom. Dia. mm Material Nom. Thickness mm Nom. Dia. mm HTR***009 4C 19 7/22/0.08 0.24 0.40 2.1 Inner jacket+ Braiding 1.0 8.3 25 HTR***010 8C 12.6 HTR***011 4C 17 7/36/0.08 0.38 0.40 2.45 9.2 16 HTR***012 8C 12.1 Application: Long distance drag chain cable Application standard: Product character