HP Flowline/Fittings
Weco Integral, Flow TEE 1-1/2" Fig.1502, F x F x M (Female x Female x Male), 15000PSI
Weco Integral Fitting. Flow Tee Size: 1-1/2", Fig.1502 Union End, F x F x M (Female(Run) x Female(Branch) x Male(Run)) / Thread Half on The Run x Threade Half on The Brunch x Wing Half on The Run. Working Pressure: 15000PSI. NACE MR-0175, H2S SERVICE
Weco Integral Fitting, Flow TEE, 4" Fig.1002, F x M x F (Female x Male x Female), 10000PSI
Weco Integral Fitting. Flow Tee Size: 4", Fig.1002 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 10000PSI.
Weco Integral Fitting, Flow TEE, 4" Fig.602, F x M x F (Female x Male x Female), 6000PSI
Weco Integral Fitting. Flow Tee Size: 4", Fig.602 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 6000PSI.
Weco Integral Fitting, Flow TEE, 3" Fig.2002, F x M x F (Female x Male x Female), 20000PSI
Weco Integral Fitting. Flow Tee Size: 3", Fig.2002 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 20000PSI.
Weco Integral Fitting, Flow TEE, 3" Fig.602, F x M x F (Female x Male x Female), 6000PSI
Weco Integral Fitting. Flow Tee Size: 3", Fig.602 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 6000PSI.
Weco Integral Fitting, Flow TEE, 2" Fig.2002, F x M x F (Female x Male x Female), 20000PSI
Weco Integral Fitting. Flow Tee Size: 2", Fig.2002 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 20000PSI.
Weco Integral Fitting, Flow TEE, 2" Fig.602, F x M x F (Female x Male x Female), 6000PSI
Weco Integral Fitting. Flow Tee Size: 2", Fig.602 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 6000PSI.
Weco Integral Fitting, Flow TEE, 4" Fig.1502, F x M x F (Female x Male x Female), 15000PSI
Weco Integral Fitting. Flow Tee Size: 4", Fig.1502 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 15000PSI.
Weco Integral Fitting, Flow TEE, 3" Fig.1502, F x M x F (Female x Male x Female), 15000PSI
Weco Integral Fitting. Flow Tee Size: 3", Fig.1502 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 15000PSI.
Weco Integral Fitting, Flow TEE, 2" Fig.1502 F x M x F (Female x Male x Female), 15000PSI
Weco Integral Fitting. Flow Tee Size: 2", Fig.1502 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 15000PSI. Any enquiry please contact us by email: Quote@VigorPetro.com and Kevin.Dai@VigorPetro.com, or visit our website: www.VigorPetro.com and www.Wellheadequip.com for more products information.
Weco Integral Fitting, Flow TEE, 2" Fig.1502 F x M x F (Female x Male x Female), 15000PSI
Weco Integral Fitting. Flow Tee Size: 2", Fig.1502 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 15000PSI. Any enquiry please contact us by email: Quote@VigorPetro.com and Kevin.Dai@VigorPetro.com, or visit our website: www.VigorPetro.com and www.Wellheadequip.com for more products information.
Weco Integral Fitting, Flow TEE, 2" Fig.1502 F x M x F (Female x Male x Female), 15000PSI
Weco Integral Fitting. Flow Tee Size: 2", Fig.1502 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Working Pressure: 15000PSI.
Weco Flow TEE 1-1/2" Fig.1502 F x M x F (Female x Male x Female)/Thread x Nut x Thread
Weco Integral Fitting. Flow Tee 1-1/2" Fig.1502 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. 15000PSI.
Weco Flow TEE 1-1/2" Fig.1502 F x M x F (Female x Male x Female)/Thread x Nut x Thread
Weco Integral Fitting. Flow Tee 1-1/2" Fig.1502 Union End, F x M x F (Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. 15000PSI. Any enquiry please contact us by email: Quote@VigorPetro.com and Kevin.Dai@VigorPetro.com, or visit our website: www.VigorPetro.com and www.Wellheadequip.com for more products information.
1" Fig.1502 Union End, Flow TEE F x M x F (Female x Male x Female)/Thread x Nut x Thread
Flow Tee 1" Fig.1502 Union End F x M x F(Female(Run) x Male(Branch) x Female(Run)) / Thread Half on The Run x Wing Half on The Brunch x Thread Hald on The Run. Integral. Any enquiry please contact us by email: Quote@VigorPetro.com and Kevin.Dai@VigorPetro.com, or visit our website: www.VigorPetro.com and www.Wellheadequip.com for more products information.
Integral Forged Tees, Crossovers, Elbows, Wyes, Laterals and Crosses
Integral Forged Tees, Crossovers, Elbows, Wyes, Laterals and Crosses Integral Forged Tees, Crossovers, Elbows, Wyes, Laterals and Crosses are based on the technology from FMC. All of them are made of high strength alloy steel and heat-treated to enhance load-bearing capacity and lengthen service life. Performances and strength are field-proven. These robust integral forged fittings are ideal for handling a complete range of standard and sour gas well servicing fluids at
2" Figure 1502 Adjustable Choke Valve, 15000PSI, API Monogramed
2" Figure 1502 Adjustable Choke Valve / Union End Choke Valve, Working Pressure 15000PSI, API Monogramed Union End Choke valves are mainly used for flow and pressure adjustment in HP pipelines. We provide two types of choke valves: fixed and adjustable. The adjustable choke valves can be divided into needle, plunger and orifice plate type. They can be manually or hydraulically operated, and conform to API 6A and 16C. Flow and pressure can be adjusted through changing fluid
Integral Pup Joint, 2" Fig1502 X 20' Non-Pressure Seal Thread (NPST), H2S, NACE MR-01-75
Integral Pup Joint, High Pressure Flowline 2" Fig1502 X 20' long, Non-Pressure Seal Thread (NPST), H2S Service, NACE MR-01-75. Date Sheet: Description End Connection Cold WP(PSI) Diameter (inch) 1-1/2" 2" 3" 4" Integral Pup Joints FIG 602 6,000psi • • • FIG 1002 10,000psi • • • FIG 1502 15,000psi • • • Integral Pup Joints for sour gas service FIG 602 5,000psi • • • FIG 1002 7,500psi • • • FIG 1502 10,000psi • • Welded Pup Joints FIG 602 6000psi • • • • FIG 1002 10,000psi
Integral Pup Joint, 2" Fig1502 X 10' Non-Pressure Seal Thread (NPST), H2S, NACE MR-01-75
Integral Pup Joint, High Pressure Flowline 2" Fig1502 X 10' long, Non-Pressure Seal Thread (NPST), H2S Service, NACE MR-01-75. Date Sheet: Description End Connection Cold WP(PSI) Diameter (inch) 1-1/2" 2" 3" 4" Integral Pup Joints FIG 602 6,000psi • • • FIG 1002 10,000psi • • • FIG 1502 15,000psi • • • Integral Pup Joints for sour gas service FIG 602 5,000psi • • • FIG 1002 7,500psi • • • FIG 1502 10,000psi • • Welded Pup Joints FIG 602 6000psi • • • • FIG 1002 10,000psi
Integral Pup Joint, 2" Fig1502 X 8' Non-Pressure Seal Thread (NPST), H2S, NACE MR-01-75
Integral Pup Joint, High Pressure Flowline 2" Fig1502 X 8' long, Non-Pressure Seal Thread (NPST), H2S Service, NACE MR-01-75. Date Sheet: Description End Connection Cold WP(PSI) Diameter (inch) 1-1/2" 2" 3" 4" Integral Pup Joints FIG 602 6,000psi • • • FIG 1002 10,000psi • • • FIG 1502 15,000psi • • • Integral Pup Joints for sour gas service FIG 602 5,000psi • • • FIG 1002 7,500psi • • • FIG 1502 10,000psi • • Welded Pup Joints FIG 602 6000psi • • • • FIG 1002 10,000psi