Digital I O Module
GE FANUC SERIES 90-30 PLC Digital I/O Module IC697CHS790 FACTORY SEALED
GE FANUC SERIES 90-30 PLC Digital I/O Module IC697CHS790 FACTORY SEALED Product Description: GE Fanuc Discrete input module for 90 - 30 series PLC offers 16 input points with one common power input terminal. It requires an AC power source for convenient operation. Module has LED indicators at the top to offer ON/OFF status of each point. Module has circuit wiring information on the surface towards the inside and circuit identification information on the outside surface.
GE FANUC SERIES 90-30 PLC Digital I/O Module IC697BEM733 FACTORY SEALED
GE FANUC SERIES 90-30 PLC Digital I/O Module IC697BEM733 FACTORY SEALED Product Description: GE Fanuc Discrete input module for 90 - 30 series PLC offers 16 input points with one common power input terminal. It requires an AC power source for convenient operation. Module has LED indicators at the top to offer ON/OFF status of each point. Module has circuit wiring information on the surface towards the inside and circuit identification information on the outside surface.
GE FANUC SERIES 90-30 PLC Digital I/O Module IC697BEM731 FACTORY SEALED
GE FANUC SERIES 90-30 PLC Digital I/O Module IC697BEM731 FACTORY SEALED Product Description: GE Fanuc Discrete input module for 90 - 30 series PLC offers 16 input points with one common power input terminal. It requires an AC power source for convenient operation. Module has LED indicators at the top to offer ON/OFF status of each point. Module has circuit wiring information on the surface towards the inside and circuit identification information on the outside surface.
GE FANUC SERIES 90-30 PLC Digital I/O Module IC693APU302 FACTORY SEALED
GE FANUC SERIES 90-30 PLC Digital I/O Module IC693APU302 FACTORY SEALED Product Description: GE Fanuc Discrete input module for 90 - 30 series PLC offers 16 input points with one common power input terminal. It requires an AC power source for convenient operation. Module has LED indicators at the top to offer ON/OFF status of each point. Module has circuit wiring information on the surface towards the inside and circuit identification information on the outside surface.
GE FANUC SERIES 90-30 PLC Digital I/O Module IC693PCM301 FACTORY SEALED
GE FANUC SERIES 90-30 PLC Digital I/O Module IC693PCM301 FACTORY SEALED Product Description: GE Fanuc Discrete input module for 90 - 30 series PLC offers 16 input points with one common power input terminal. It requires an AC power source for convenient operation. Module has LED indicators at the top to offer ON/OFF status of each point. Module has circuit wiring information on the surface towards the inside and circuit identification information on the outside surface.
DEMO MR-J3-D01 Servo Motor Amplifier Digital I/O Module Interface Mitsubishi
Industrial Servo Drives Mitsubishi MR-J3-500A AC SERVO Amplifier 5kW SPECIFICATION: EUA Stock No31007 Brand/ManufacturerMitsubishi Manufacturer Part NumberMR-J3-D01 Product typeServo Amplifier Supply voltage24 V dc Current rating:800 mA Single Axis Motion Controller (OS included) Model Number MR-MQ100 Stocked Item S Power Supply 24VDC ±10% (Required Current Capacity 400mA) Digital Inputs* 20 Inputs (AI = 2, AO = 2) Digital Outputs* 18 Synchronous Encoder Signal Type A/B Phase
ABB Digital I O Module 24 V d.c (19.2 -30 V) TU849 3BSE042560R1 500 V a.c
ABB Digital I O Module 24 V d.c (19.2 -30 V) TU849 3BSE042560R1 500 V a.c The TU849 is a module termination unit (MTU) for redundant configuration of Optical ModuleBus Modem TB840/TB840A. The MTU is a passive unit having connections for double power supply, one for each modem, a single electrical ModuleBus, two TB840/TB840A and a rotary switch for cluster address (1 to 7) setting. Four mechanical keys, two for each position, are used to configured the MTU for the right types
ABB's Modulebus TU848 3BSE042558R1 24 V d.c (19.2 -30 V) Digital I O Module
ABB's Modulebus TU848 3BSE042558R1 24 V d.c (19.2 -30 V) Digital I O Module The TU848 is a module termination unit (MTU) for redundant configuration of Optical ModuleBus Modem TB840/TB840A. The MTU is a passive unit having connections for double power supply (one for each modem), double electrical ModuleBus, two TB840/TB840A and a rotary switch for cluster address (1 to 7) setting. Two mechanical keys are used to configured the MTU for the right types of modules. Each key has
24 V d.c. (19.2 - 30 V) Digital I O Module TU847 3BSE022462R1 500 V a.c
24 V d.c. (19.2 - 30 V) Digital I O Module TU847 3BSE022462R1 500 V a.c General info Protocol ABB's Modulebus Article number 3BSE022462R1 Master or slave Not Applicable Module redundancy Yes Hot Swap No Type Redundant CI840/CI840A, Single I/O Power input 24 V d.c. (19.2 - 30 V) Mounting Vertical or Horizontal Detailed data Connector PROFIBUS. DSUB9 connector Service ports: RJ45 connector 24 V consumption typ. N/A ModuleBus current distribution Maximum 5 V 1.5 A Maximum 24 V 1
CI868 3BSE048845R1 Master / Slave RJ-45 female (8-pin) Digital I O Module ABB
CI868 3BSE048845R1 Master / Slave RJ-45 female (8-pin) Digital I O Module ABB General info Protocol IEC 61850 Article number 3BSE048845R1 Master or slave Master / Slave Transmission speed 10/100 Mbit/s Line redundancy No Module redundancy No Hot Swap Yes Used together with HI Controller Yes Detailed data Max units on CEX bus 12 Connector RJ-45 female (8-pin) 24 V consumption typ. typ 160 mA Environmental and certification Temperature, Operating 55 °C Protection class IP20
CI860 3BSE032444R1 Digital I O Module 10/100 Mbit/s RJ-45 female (8-pin)
CI860 3BSE032444R1 Digital I O Module 10/100 Mbit/s RJ-45 female (8-pin) General info Protocol FOUNDATION Fieldbus HSE Article number 3BSE032444R1 Master or slave Master / Slave Transmission speed 10/100 Mbit/s Line redundancy No Module redundancy Yes Hot Swap Yes Used together with HI Controller No Detailed data Max units on CEX bus 12 Connector RJ-45 female (8-pin) 24 V consumption typ. typ 100 mA Environmental and certification Temperature, Operating 55 °C Protection class
Digital I O Module CI858 3BSE018135R1 ABB DriveBus typ 200 mA
Digital I O Module CI858 3BSE018135R1 ABB DriveBus typ 200 mA The DriveBus protocol is used to communicate with ABB Drives and ABB Special I/O units. DriveBus is connected to the controller via a CI858 communication interface unit. The DriveBus interface is used for communication between ABB Drives and AC 800M controller. The DriveBus communication is especially designed for sectional drive applications for ABB rolling mill drive systems, and ABB paper machine control systems
CI857 3BSE018144R1 Digital I O Module RJ-45 female (8-pin) 150 mA
CI857 3BSE018144R1 Digital I O Module RJ-45 female (8-pin) 150 mA General info Protocol ABB's INSUM Article number 3BSE018144R1 Master or slave Master Transmission speed 10 Mbit/s Line redundancy No Module redundancy No Hot Swap Yes Used together with HI Controller Yes Detailed data Max units on CEX bus 6 Connector RJ-45 female (8-pin) 24 V consumption typ. typ 150 mA INSUM integration into AC 800M supports higher functionality integration, multidrop configurations, time
120 mA S100 I/O communication Digital I O Module CI856 3BSE026055R1
120 mA S100 I/O communication Digital I O Module CI856 3BSE026055R1 General info Protocol ABB's S100 I/O Article number 3BSE026055R1 Master or slave Master Transmission speed - Line redundancy No Module redundancy No Hot Swap Yes Used together with HI Controller Yes Detailed data Max units on CEX bus 12 Connector Miniribbon (36-pin) 24 V consumption typ. typ 120 mA Environmental and certification Temperature, Operating 55 °C Protection class IP20 according to EN60529, IEC 529
PM891K02 3BSE053242R1 24 V DC (19.2-30 V DC) 660/750 mA 10/100 Mbit/s ABB
PM891K02 3BSE053242R1 24 V DC (19.2-30 V DC) 660/750 mA 10/100 Mbit/s ABB The PM891 processor is a monolithic unit equipped with power supply, CPU-boards and unit termination. The unit contains microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button and a Secure Digital interface. The PM891 does not contain any internal battery The PM891 has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and one RJ45 serial port (COM4).
24 MHz 0.46 ms 16 MB (from 800xA 5.1 FP4) PM856AK01 3BSE066490R1 Digital I O Module
24 MHz 0.46 ms 16 MB (from 800xA 5.1 FP4) PM856AK01 3BSE066490R1 Digital I O Module The CPU board contains the microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button, and a CompactFlash interface. The base plate of the PM856A controller has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and two RJ45 serial ports (COM3, COM4). One of the serial ports (COM3) is an RS-232C port with modem control signals, whereas the other
BC810K02 3BSE031155R1 Digital I O Module 50 mA typical (70 mA max) 1.2 W typical
BC810K02 3BSE031155R1 Digital I O Module 50 mA typical (70 mA max) 1.2 W typical General info Article number 3BSE031155R1 (BC810K02) Redundancy Yes High Integrity Yes Performance Hot swap supported Detailed data Power supply Inputs designated L+ and L- 24 V nominal, variation between 19.2 V DC and 30 V DC. Power consumption +24 V typ/max 50 mA typical (70 mA max) Power dissipation typ. 1.2 W typical Environmental and certification Temperature, Operating +5 to +55 °C (+41 to
Redundant TU846, Redundant I/O 3BSE022460R1 Digital I O Module ABB
ABB's Modulebus Digital I O Module Redundant Single I/O, Single Power TU841 3BSE020848R11 Features and benefits • Power supply connection. • Two PROFIBUS connections. • Two service tool connections. • Two rotary switch for station address setting. • Connection for two ModuleBuses. • Connector for ModuleBus Optical Port. • Mechanical keying prevents insertion of the wrong module type. • Latching device to DIN rail for locking and grounding. • DIN rail mounted. The TU846 is a
ABB's Modulebus Digital I O Module Redundant Single I/O, Single Power TU841 3BSE020848R11
ABB's Modulebus Digital I O Module Redundant Single I/O, Single Power TU841 3BSE020848R11 Features and benefits • A rotary switch for cluster address setting • Mechanical keying prevents insertion of wrong module type • Single ModuleBus connection • Latching device to DIN rail for locking and grounding • DIN rail mounted The TU841 is a module termination unit (MTU) for redundant configuration of Optical ModuleBus Modem TB840/TB840A, for use with non-redundant I/O. The MTU is
Digital I O Module 3BSE037760R1 TB840A ABB 24 V consumption typ 120 mA
Digital I O Module 3BSE037760R1 TB840A ABB 24 V consumption typ 120 mA General info Protocol ABB's Modulebus Article number 3BSE037760R1 Master or slave Slave Line redundancy Yes Module redundancy Yes Hot Swap Yes Used together with HI Controller Yes Detailed data 24 V consumption typ. 120 mA Environmental and certification Temperature, Operating 0 to +55 °C Temperature, Storage -25 to +70 °C Pollution degree Degree 2, IEC 60664-1 Corrosion protection ISA-S71.04: G3 Relative