Transformer Testing Equipment
Transformer CT Current Transformer Testing Equipment On-Site Calibrator 0.05S Accuracy 5A-25000A
High-precision on-site calibrator for CT and PT testing with 0.05S accuracy. Features recursive error measurement, variable frequency power supply, and wide range 5A-25000A. Eliminates need for standard CT and load box. Includes large LCD, auto error rounding, and RS232/USB data export. Durable mold box.
ZXR-10A+ Three Phase Transformer DC Winding Resistance Tester 10A 5A 1A Three Channels
Measures three circuits simultaneously for YN, Y, and delta transformers. Features 10A, 5A, 1A output, 0.1μΩ resolution, and 0.2% accuracy. Compact, lightweight, with English interface and menu prompts. Ideal for efficient transformer testing.
ZXR-40A 40A DC Winding Resistance Tester for Transformer Field Test with 0.2% Accuracy
High-precision ZXR-40A tester measures transformer DC resistance with 40A output. Features fast response, automatic discharge alarm, and strong anti-interference. Ideal for field use with compact design and 0.2% accuracy.
ZX-BZK Lightweight Transformer Short Circuit Impedance Tester 0-250V 0-10A
Compact and portable short circuit impedance tester for 110kV and above transformers. Features single-phase measurement, phase-locking technology, and LCD display. Supports external CT/PT. Ideal for on-site winding deformation checks. Factory direct with 1-year warranty.
10KVA-30KVA Transformer Partial Discharge Testing Machine PD Test Equipment
Compact and lightweight partial discharge detector for transformers. 40-65% lighter than oil-immersed units, maintenance-free, and unaffected by harsh climates. High insulation strength with low corona. Ideal for reliable PD testing.
JSY-03 GB/T19001 Anti Interference Transformer Tan Delta Tester 10kV 45-55Hz
Measures dielectric loss factor (tgδ) and capacitance of transformers, bushings, capacitors, and arresters. Features strong anti-interference, 10kV auto boost, 45/55Hz variable frequency, and high accuracy. Compact with built-in HV supply, RS232 interface, and safety protections. ISO9001 certified.
Power Transformer Winding Deformation Tester 10MHz Sweep Frequency Response Analyzer
Detect transformer winding deformation via frequency response analysis per DL/T911-2004. Features 10MHz sweep, 0.1dB accuracy, wireless WiFi/Bluetooth connectivity, and auto analysis. Ideal for 6kV+ transformers. Custom options available.
10kV Capacitance Tan Delta Tester Power Transformer Testing Equipment 45Hz 55Hz
Automatic frequency conversion tan delta tester for dielectric loss measurement of transformers, bushings, and arresters. Features strong anti-interference, 10kV output, and high accuracy. Ideal for field use in substations with electromagnetic interference.
Transformer On Load Tap Changer AC Parameter Tester 200k/s 500V for On Site Testing
AC method tester for on load tap changers, capturing true transition waveforms without filtering. Tests 10kV-500kV, features 200k/s sampling, 8M byte cache, and built-in power supply. Portable, touch screen, and supports data export for analysis.
On Load Tap Changer Tester AC DC Electrical Parameter Test Equipment 200k/s 500V
Tests transition waveform, time, resistance, and three-phase sync for 10kV-500kV transformers. Features 200k/s sampling, 8MB cache, 10.4" touch screen, and built-in power supply. Portable, CE certified, with data export and remote transmission.
ZXR-40A Transformer Winding Resistance Tester 40A DC Resistance Meter Fast Response Sound Discharge Alarm
High-precision 40A DC resistance meter for transformer testing. Features fast response, sound discharge alarm, and automatic discharge. Ideal for medium and large transformers with 0.2% accuracy and 0.1μΩ resolution.
ZX-BRL 750V 100A Transformer Capacity Loss Parameters Tester High Precision Passive Active Measurement
The ZX-BRL tester measures transformer capacity, no-load loss, and short-circuit loss with high precision. Built-in rechargeable Li-battery supports 100 tests per charge. Features auto calibration, external CT/PT support, and a thermal printer. Ideal for B2B industrial export.
Full-Automatic Three Phase Transformer On-Load Switch Tester 3A 1A 0.6A 0.2A 100 Ohm
Measures transition time, resistance, and three-phase synchronism of on-load tap changers. Features 0.1ms time resolution, 0.1 Ohm resistance resolution, and 300ms waveform recording. Supports Y0, Y, and Delta transformers with direct resistance display. Includes touch screen, printer, and USB data export.
ZX-BCS 0.1 Accuracy Portable Automatic Transformer Turns Ratio Tester 0.8-10000 Range
High-speed TTR tester with 0.1% accuracy, 5-inch LCD, and built-in lithium battery for field use. Measures turns ratio, phase angle, and connection group. Supports single/three-phase and tap tests. Lightweight 3kg, stores 1000 results.
Digital Sweep Frequency Response Transformer Winding Deformation Tester 0.1dB Accuracy 10MHz
Measures transformer winding deformation via frequency response analysis per DL/T911-2004. Features 10MHz sweep, 0.1dB accuracy, wireless WiFi/Bluetooth connectivity, and auto analysis. Fast 60s per phase test. Ideal for 6kV+ power transformers.
ZX-BCS Multifunctional 3 Phase Transformer Turns Ratio Tester 0.8-10000 Range
Measures turns ratio, phase angle, and error for Z/Scott transformers. Features 7-inch LCD, 0.1% accuracy, and 40-second three-phase test. Built-in lithium battery, lightweight 3kg. Ideal for industrial power testing.
On Load Tap Changer Tester AC DC Parameter Transformer Testing Equipment 200k/s
High-speed 200k/s sampling for true transition waveform analysis. Tests 10kV-500kV transformers with AC/DC methods. Built-in 1000VA power supply, 10.4" touch screen, and 8M byte FIFO cache. Supports data export and remote transmission. Portable, integrated design for on-site use.
JSY-03 10kV Automatic Transformer Oil Tan Delta Dielectric Loss Tester with 45/55Hz Variable Frequency
The JSY-03 Tan Delta Tester offers high-precision dielectric loss measurement for transformers, bushings, and arresters. Features automatic frequency conversion, strong anti-interference up to 200%, and 10kV output. Ideal for field use in power plants. Compact design with built-in standard capacitor and HV supply.
Electronic Automatic Transformer On Load Tap Change Tester 1.0A 0.5A 0.3A
Measures transition waveform, time, resistance, and three-phase synchronization. Features 1.0A/0.5A/0.3A output, 5.7-inch LCD, U disk storage, and strong anti-interference. Ideal for power plants and transformer manufacturing.
Micro Computer System Power Transformer On Load Tap Changer Tester 1.0A 0.5A 0.3A
Measures transformer on-load tap changer transition waveform, time, resistance, and three-phase synchronization. Features 1.0A/0.5A/0.3A output, 28V open circuit voltage, 5.7-inch LCD, U disk storage, and strong anti-interference. Ideal for power plants and transformer manufacturing.