PERKINS Diesel Generator Set
113KVA 90KW PERKINS Diesel Generator Set High Water Temperature Protection
PERKINS Diesel Generator Set ,113KVA/90KW 60Hz PERKINS Diesel Engine Model 1104C-44TAG2 Generator set Genset Model SP113E6 Standby power 123.75KVA/99KW Rated power 113KVA/90KW Output voltage 230v/400v Frequency 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 50°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below one thousand (1000) meters
Electrical 50Hz 80KW Perkins 100 Kva Diesel Generator High Performance
PERKINS Diesel Generator Set ,100KVA/80KW 50Hz PERKINS Diesel Engine Model 1104C-44TAG2 Generator set Genset Model SP100E5 Standby power 110KVA/88KW Rated power 100KVA/80KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 21.4L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude
Efficient PERKINS 60kva Diesel Generator 50HZ Frequency AC Three Phase Output
PERKINS Diesel Generator Set ,80KVA/64KW 50Hz PERKINS Diesel Engine Model 1104A-44TG2 Generator set Genset Model SP80M5 Standby power 88KVA/70.4KW Rated power 80KVA/64KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 69.8dB(A)/59.2dB(A) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 18.7L/h (100%Load) Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80
Stable Performance Perkins Soundproof Generator 36KW With Water Cooled System
PERKINS Diesel Generator Set ,33KVA/26KW 50Hz PERKINS Diesel Engine Model 404D-22G Generator set Genset Model SP45M5 Standby power 49KVA/39KW Rated power 45KVA/36KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 76.1dB(A)/66.9dB(A) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 10.7L/h (100%Load) Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80%
26KW PERKINS Diesel Generator Set 50HZ Frequency Open Controller Output
PERKINS Diesel Generator Set ,33KVA/26KW 50Hz PERKINS Diesel Engine Model 404D-22G Generator set Genset Model SP33M5 Standby power 36KVA/29KW Rated power 33KVA/26KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 67.14dBA Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 5.3L/h (100%Load) Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below
Industrial 24kw Diesel Generator / Perkins Diesel Power Generator Low Oil Pressure Protection
PERKINS Diesel Generator Set ,30KVA/24KW 50Hz PERKINS Diesel Engine Model 1103A-33G Generator set Genset Model SP30M5 Standby power 33KVA/26.4KW Rated power 30KVA/24KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 67dBA Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 7.1L/h (100%Load) Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below
AC Three Phase PERKINS Diesel Generator Set Low Oil Pressure Protection
PERKINS Diesel Generator Set ,27KVA/22KW 50Hz PERKINS Diesel Engine Model 404D-22TG Generator set Genset Model SP27M5 Standby power 30KVA/24KW Rated power 27KVA/22KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 65dBA Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 7.1L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below
Durable PERKINS Diesel Generator Set 22KVA 18KW With Stable Performance
PERKINS Diesel Generator Set , 22KVA/18KW 50Hz PERKINS Diesel Engine Model404D-15G Generator set Genset Model SP22M5 Standby power 24KVA/19KW Rated power 22KVA/18KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 66.2dBA Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 3.67L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below
SP20M5 PERKINS Diesel Generator Set AC Three Phase Output 50HZ Frequency
PERKINS Diesel Generator Set , 20KVA/16KW 50Hz PERKINS Diesel Engine Model 404D-22G Generator set Genset Model SP20M5 Standby power 22KVA/17.2KW Rated power 20KVA/16KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 59.3dBA Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 6.2L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude
Precision PERKINS Diesel Generator Set 69KVA / 55KW 60Hz AC Three Phase Output
PERKINS Diesel Generator Set ,69KVA/55KW 60Hz PERKINS Diesel Engine Model 1103A-33TG2 Generator set Genset Model SP69M6 Standby power 68.1KVA/54.5KW Rated power 69KVA/55KW Output voltage 230v/400v Frequency 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below one thousand (1000) meters Max
60 Hz Frequency PERKINS Diesel Generator Set 3.3L Displacement Low Oil Pressure Protection
PERKINS Diesel Generator Set ,53KVA/43KW 60Hz PERKINS Diesel Engine Model 1103A-33TG1 Generator set Genset Model SP53M6 Standby power 58KVA/47KW Rated power 53KVA/43KW Output voltage 230v/400v Frequency 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below one thousand (1000) meters Max
SP18M5 PERKINS Diesel Generator Set 4 Stroke Cycle Over Load Protection
PERKINS Diesel Generator Set , 18KVA 14KW 50Hz PERKINS Diesel Engine Model 403D-11G Generator set Genset Model SP18M5 Standby power 20KVA/16KW Rated power 18KVA/14KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 64 Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 2.6L/h (100%Load) Ambient temperature -25°C to 50°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below one
Three Phase AC Diesel Generator Perkins Soundproof Generator High Performance
PERKINS Diesel Generator Set ,32KVA/26KW 60Hz PERKINS Diesel Engine Model 404D-22TG Generator set Genset Model SP32M6 Standby power 36KVA/29KW Rated power 32KVA/26KW Output voltage 230v/400v Frequency 60 Hz Noise level(7m) 68dB(A) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below one thousand (1000) meters Max
60HZ Frequency PERKINS Diesel Generator Set AC Three Phase Output 24KVA / 19KW
PERKINS Diesel Generator Set , 24KVA/19KW 60Hz PERKINS Diesel Engine Model 404D-22G Generator set Genset Model SP24M6 Standby power 26KVA/21KW Rated power 24KVA/19KW Output voltage 230v/400v Frequency 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below one thousand (1000) meters Max currency
SP11M6 Small Diesel Generator Set / 9kw Diesel Generator Battery Start Mode
PERKINS Diesel Generator Set , 11KVA/9KW 60Hz PERKINS Diesel Engine Model 403D-11G Generator set Genset Model SP11M6 Standby power 12KVA/10KW Rated power 11KVA/9KW Output voltage 230v/400v Frequency 60 Hz Noise level(7m) N/A Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below one thousand (1000) meters Max currency
7KVA 6kw Diesel Generator 60Hz Frequency 3 Phase 4 Wires Over Load Protection
PERKINS Diesel Generator Set , 7KVA/6KW 60Hz PERKINS Diesel Engine Model 403D-07G Generator set Genset Model SP7M6 Standby power 8.25KVA/6.6KW Rated power 7KVA/6KW Output voltage 230v/400v Frequency 60 Hz Noise level(7m) 56dB(A) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude Below one thousand (1000) meters Max
AC Three Phase Perkins Diesel Power Generator 13KVA / 10KW Over Speed Protection
PERKINS Diesel Generator Set , 13KVA/10KW 50Hz PERKINS Diesel Engine Model 403D-15G Generator set Genset Model SP13M5 Standby power 13.5KVA/10.8KW Rated power 13KVA/10KW Output voltage 230v/400v Frequency 50 Hz Noise level(7m) 54.6dB(A) Power factor COSΦ=0.8(lagging) Phase/wires 3 phase 4 wires Start mode Battery Fuel consumption 3.7L/h (100%Load) Ambient temperature -25°C to 45°C. The coolant heater is needed when the temperature is below 5°C Humidity Less than 80% Altitude
3 Phase PERKINS Diesel Generator Set , 50Hz 144KW 180KVA PERKINS Silent Generator
Silent 3 Phase 50Hz 144kw 180kva Diesel Generator powered by Perkins Output Ratings: Gensets Model Prime Power Standby Power kW kVA kW kVA SP180M5 144 180 158 200 Voltage 380V-415V 220V-240V 190V-208V Amps 250-274 433-473 499-547 lStandard open type is good to working in engine room with ventilation system. lThe super silent model (up to 50kw) has electronic cooling fan and special design low noise level canopy. which is specialized for low noise level environment, such as
Latest Design Open Type Small Diesel Generator Set With Engine Model 403D-11G
Open type 50hz 9kva Specification of new design Diesel Generator Powered by Perkins Output Ratings: Gensets Model Prime Power Standby Power kW kVA kW kVA SP9M5 7 9 8 10 Voltage 380V-415V 220V-240V 190V-208V Amps 12-13 21-23 24-27 Ratings and Performance Data Engine Brand Perkins Engine Model 403A-11G1 Alternator Brand Stamford Alternator Model PI044E Control System DSE6020 / DSE7320 Standard Noise Level@7m 85 db (Open Sets) Circuit Breaker Type 3 Pole MCCB Frequency & Phase
4 Stroke 10KW 13KVA PERKINS Diesel Generator Set Powered By Engine Model 403D-15G
4 Stroke 50HZ 10KW 13KVA Silent PERKINS Diesel Generator powered by 403D-15G Product description: Output RatingsGensetsModelPrime PowerStandby PowerkWkVAkWkVATP13PC1S10131114 Voltage380V-415V220V-240V190V-208VAmps17-1930-3335-38 Ratings at 0.8 power factor1) Ambient reference conditions: 1,000 mbar, 27℃, 30% relative humidity;2) ESP: Standby Power Standby duty, operation under variable load, without over load;3) PRP: Prime Power-Continuous duty operation, under variable load