Water Quality Sensor
KWS-1000 Online Oil in Water Sensor with RS-485 Output, Automatic Cleaning Brush, and Ultraviolet Fluorescence Analysis
KWS-1000 Online crude oil-In-Water SensorFeatureDigital sensor, RS-485 output, support MODBUSOptional automatic cleaning brush to eliminate the impact of oil on the measurementEliminate the impact of ambient light on measurements with unique optical and electronic filtering techniquesIt is not affected by suspended solids in waterIntroductionKacise online water sensor uses the principle of fluorescence. Compared with several commonly used methods, the fluorescence method is
IP68 Water Chlorine Sensor with 0.001mg/L Resolution Using Constant Voltage Method for Accurate Residual Chlorine Monitoring
Water Chlorine Sensor 1. Applications Kacise on-line residual chlorine sensor is used to monitor the residual chlorine content continuously in drinking water treatment plant, canning plant, drinking water distribution network, swimming pool, cooling circulating water, water quality treatment project. 2. Technical Specifications Module No. KWS-3000 Principle the constant voltage method Range 0~2.000mg/L(HClO) Accurate ±5% or ±0.05mg/L Resolution 0.001mg/L Calibration Function
GPRS Wireless Water Quality Sensor with RS-485 MODBUS Protocol 1% Accuracy and IP68 Waterproof for Online Dissolved Oxygen Measurement
KWS610A Fluorescent water quality MeasurementSystem Manual GPRS communication mode 1. System summary "Water quality measurement system in GPRS communication mode" includes "water quality measurement terminal equipment in GPRS communication mode", "server management software" and "configuration line". It is used to periodically measure dissolved oxygen content, temperature values, longitude and latitude data, date and time information, and display these val
KWS-600 Online Fluorescence Dissolved Oxygen Sensor with No Membrane No Electrolyte RS485 Modbus Output and IP68 Waterproof
KWS-600 Online Fluorescence Dissolved Oxygen Sensor No Membrane No Electrolyte And No Interference 1. Feature Kacise dissolved oxygen sensor support RS485/Modbus communication. Optional automatic cleaning brush to eliminate the impact of oil on the measurement, this product uses a unique optical and electronic filtering technology to eliminate the impact of ambient light on the measurement, not affected by suspended solids. Best-in-class fluorescence lifetime technology and
RS485 Output Dissolved Oxygen Sensor with IP68 Grade and Fluorescence Technology for Aquaculture
Dissolved Oxygen Sensor For Shrimp Farm And Pond Dissolved Oxygen Sensor Introduction The Kacise KWS-610 fluorescence dissolved oxygen sensor is designed for the aquaculture industry. It has the characteristics of stable online monitoring, and it has excellent characteristics compared with the traditional type sensor. It has no membrane, no need electrolyte, strong anti-interference, no need for frequent calibration, no consumption of oxygen, no flow rate limitation, auto
Dual High Impedance KPH601 Online PH Sensor with Auto Temperature Compensation and RS-485 Output
KPH601 Online PH Sensor Signal Output: RS-485 (Modbus/RTU Protocol) 1. Temperature compensation The pH range (0-14) is determined through the ion product of the water, which to a very small extent dissociates into H+ and OH– ions. [H+ ] [OH– ] = 10–14 = I (25°C) The ion product I is strongly dependent on temperature. The temperature influences the pH measurement through four factors: Chemical equilibria are temperature dependent Temperature dependence of the slope (see Nernst
Dual High Impedance KPH601 Online PH Sensor with RS-485 Output and Auto Temperature Compensation
KPH601 Online PH Sensor Signal Output: RS-485 (Modbus/RTU Protocol) 1. Obtaining an accurate pH measurement Buffer solutions For extremely accurate measurements National Institute of Standards and Technology (NIST) buffer solutions are recommended. These buffer solutions are the basis of the practical pH scale and have been adapted in the DIN 19266. However, they are almost exclusively used in the laboratory. Buffers customarily used (e.g. potassium dihydrogen phosphate and
Dual High Impedance KPH601 Online pH Sensor with RS-485 Output and Auto Temperature Compensation
KPH601 Online PH Sensor Signal Output: RS-485 (Modbus/RTU Protocol)1. Why are pH values measured?We measure pH for a lot of different reasons, such as:to produce products with defined properties – During production it is important to control the pH to ensure that the end product conforms with the desired specifications. The pH can dramatically alter the properties of an end product such as appearance or taste.to lower production costs – This is related to the above-mentioned
KPH500 IP68 Protection PVC Material PH Meter with 2% Calibration Accuracy for Water Quality Monitoring
Production Introduction The PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is
KPH500 PH Sensor Water Quality Analyzer with 0-14PH Measuring Range IP68 Protection and Automatic Temperature Compensation
KPH500 ph plant sensors water quality analyzer ph meter ph controller ph/o ph sensorProduction IntroductionThe PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media
KPH500 PH Sensor Water Quality Analyzer with 0-14PH Measuring Range Automatic Temperature Compensation and 485 Communication
Production IntroductionThe PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is
KPH500 Micro Water Quality Sensor PVC PH ORP Meter Controller with 0-14PH Range and IP68 Protection
Production Introduction The PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is
KPH500 PH/ORP Meter with 0-14PH Measuring Range PVC Material and IP68 Protection Level for Waste Water
Production Introduction The PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is
KPH500 PH Sensor with 4-20mA Output and IP68 Protection for Seawater Water Quality Meter with Automatic Temperature Compensation
Production IntroductionThe PH/ORP meter is a precision meter used to detect the pH/oxidation-reduction potential of liquids. It is designed with a microcomputer based on the principle of the primary battery and is simple to operate and easy to maintain. Not affected by color, turbidity, colloidal substances, oxidants and reducing agents, it is suitable for the determination of various media such as clean water, wastewater, industrial water, chemical reagents, etc., and is
Portable Conductivity Meter SC92 with IP67 Waterproof, Wide Measuring Range, and Large Backlit Display
Portable Conductivity Meter SC92 Wide Measuring Range, Your Daily Measuring Partner Tough and Easy-to-Use Portable Conductivity Meter Our long-selling Personal Conductivity Meter has been redesigned as a Portable Conductivity Meter with enhanced ease of use. Connecting the appropriate sensor for the application can measure the entire conductivity range of 0-2 S/cm and retain accuracy when measuring 0-2 µS/cm or resistivity. This handheld conductivity meter has an IP67
SC25V pH Sensor with External Titanium Liquid Earth Built-in Temperature Sensor and Hazardous Area Certification
pH sensor SC25V with external liquid earth and built-in temperature sensor Having a stable, reliable and accurate measurement is of vital importance for pH measurement and control. The SC25V pH sensor has been developed and designed to ensure it delivers these results in every application. The built-in temperature sensor is located close to the pH measuring glass, resulting in increased accuracy of temperature compensation and therefore the pH measurement. The integrated
KWS-850 Multi-parameter Water Quality Sensor with RS-485(Modbus/RTU) Output, Automatic Cleaning, and ±0.1pH Accuracy for Wastewater Treatment
KWS-850 On-line Multi-Parameter Water Quality Sensor The KWS-850 on-line multi-parameter water quality sensor is an indispensable asset for wastewater treatment plants. It is meticulously designed to meet the complex demands of monitoring and treating diverse wastewater streams. This advanced sensor can simultaneously measure multiple crucial parameters including pH level, dissolved oxygen, conductivity, turbidity, total dissolved solids (TDS), and specific contaminants. With
Compact and Durable Online COD Sensor with COD Accuracy ±5% for Wastewater Treatment
Introduction Dissolved organic compounds in water frequently absorb UV radiation. Measuring the absorption of 254 nm UV light by these substances provides an accurate method for determining the concentration of dissolved organic pollutants in the water. The KWS-150 online COD sensor incorporates two separate light sources: one for measuring the COD concentration via ultraviolet light and another for assessing water turbidity. Furthermore, an advanced algorithm compensates for
Multiparameter Water Quality Meter with RS485 Output MODBUS Protocol and Automatic Cleaning Function
Multiparameter Water Quality Meters & Probes 1. Feature Digital sensor, RS485 output, support MODBUS, all calibration parameters are stored in the sensor, each probe has a waterproof connector, which can be easily plugged and replaced. Equipped with automatic cleaning function, it can effectively remove sensor surface contamination, prevent microbial growth, and be more accurate and less maintenance. Optional fluorescence dissolved oxygen, four-electrode conductivity, fiber
KSM-150B Wall Mounted Residual Chlorine Meter with Non-Membrane Sensor and 4-20mA Output
KSM-150B Wall Mounted Residual Chlorine Meter Product Overview This advanced intelligent water quality detector features non-membrane constant voltage sensor technology, eliminating the need for diaphragm and reagent replacement. With high sensitivity, rapid signal response, and precise measurement capabilities, it delivers stable performance with minimal maintenance requirements. The instrument offers English menu operation, superior stability, excellent repeatability, and