Eaton Vickers Hydraulic Pump
V2020 Series Eaton Vickers Vane Pump Parts Fixed Displacement Hydraulic
Vickers V10/V20/V2010/V2020 Single and Double Vane Pumps Introduction * Series V10, V20, V2010, and V2020 fixed displacement pumps are of Vickers “balanced vane type” construction. V10 and V20 single pumps have rated flow capacities of 1 to 7 USgpm and 6 to 13 USgpm, respectively. Double pumps provide a single power source capable of serving two separate hydraulic circuits, or of providing greater volume through the combined delivery of both sections. In either type of
Vickers 02-341552 PVQ20-B2R-SE1S-20-C21-11 PVQ20 Series Piston Pump
Eaton Vickers PVQ Series Piston Pumps Variable Displacement, Quiet Series for Industrial AppliSAARions PVQ10,PVQ13,PVQ20,PVQ25,PVQ32,PVQ40,PVQ45 Features Operating pressure up to 210 bar (3000 psi) Control type with compensator control “C” or “CM”, etc. Displacement from 10, 5 to 45 cm3/r (0.64 to 2.75 in3/r) Speed up to 1800 r/min PVQs operate at quietness levels that meet today's demanding industrial conditions. The sound level of each unit approaches or is below that of the
50V109A-1A10-132 50V109A-1A11-132 Eaton Vickers 50V Type Vane Pump
Eaton Vickers Single Vane Pumps V Series - Low Noise Vane Pumps 20V, 25V, 35V, 45V, 50V Features and Benefits • High operating pressure capabilities in compact packages provide high power to weight ratios and lower installed costs. • Low noise characteristics inherent in intravane design enhance operator comfort. • Twelve vane system provides low amplitude flow pulsations resulting in low system noise characteristics. • Hydraulic balancing, designed to prevent internally
Vickers Vane 361166-3 25M42A-1C20 High Speed Vane Motors
Eaton Vickers High Speed Vane Motors 25M, 35M, 45M, 50M 25M - 50M Motors Features High Efficiency A unique dual pressure plate design results in low internal leakage and overall operating efficiencies up to 90%. Efficiency varies with motor size, pressure, speed, and fluid viscosity and temperature. Mounting Flexibility The motor’s cover can be assembled in four positions with respect to the body. Changing port positions is accomplished by simply rotating the cover, and the
295058-6 50V100A-1B11-130L Eaton Vickers 50V Type Vane Pump
Eaton Vickers Single Vane Pumps V Series - Low Noise Vane Pumps 20V, 25V, 35V, 45V, 50V Features and Benefits • High operating pressure capabilities in compact packages provide high power to weight ratios and lower installed costs. • Low noise characteristics inherent in intravane design enhance operator comfort. • Twelve vane system provides low amplitude flow pulsations resulting in low system noise characteristics. • Hydraulic balancing, designed to prevent internally
502724-7 50V100A-11C11-130-LH Eaton Vickers 50V Type Vane Pump
Eaton Vickers Single Vane Pumps V Series - Low Noise Vane Pumps 20V, 25V, 35V, 45V, 50V Features and Benefits • High operating pressure capabilities in compact packages provide high power to weight ratios and lower installed costs. • Low noise characteristics inherent in intravane design enhance operator comfort. • Twelve vane system provides low amplitude flow pulsations resulting in low system noise characteristics. • Hydraulic balancing, designed to prevent internally
706998-1 V20-1B13B-1A11-EN1000 Vickers Single Vane Pump
Vickers V10/V20/V2010/V2020 Single and Double Vane Pumps Introduction * Series V10, V20, V2010, and V2020 fixed displacement pumps are of Vickers “balanced vane type” construction. V10 and V20 single pumps have rated flow capacities of 1 to 7 USgpm and 6 to 13 USgpm, respectively. Double pumps provide a single power source capable of serving two separate hydraulic circuits, or of providing greater volume through the combined delivery of both sections. In either type of
Vickers 02-305663-3 F3-20V5A-1C22R Vickers Double Vane Pump
Eaton Vickers Double Vane Pumps 2520V, 2525V, 3520V, 3525V, 4520V, 4525V, 4535V Series - Low Noise Vane Pumps Features and Benefits • High operating pressure capabilities in compact packages provide high power to weight ratios and lower installed costs. • Low noise characteristics inherent in intravane design enhance operator comfort. • Twelve vane system provides low amplitude flow pulsations resulting in low system noise characteristics. • Hydraulic balancing, designed to
PVH Series Variable Displacement Piston Pump 02-125777 PVH098R13AJ30A250000001AM1AB010A
SAAR specialized in pumps, motors, valves, bearings, couplings, gearbox, engine spare parts, filter elements, fittings, connectors, electronic components and accessories, mobile equiupment spare parts. Eaton Vickers PVH Series Variable Displacement Piston Pumps PVH Series Benefits • Versatile design includes single pumps, thru-drive arrangements, and a variety of drive shaft and control options that will adapt to any appliSAARion and provide the most cost effective installatio
Eaton 02-346207 PVH57C-RF-1S-11-C25VT4-31 Vickers Variable Axial Piston Pump Old Version
Eaton Vickers PVH Variable Axial Piston Pump Old Version PVH- 98- QI- C- R- ﹡ F- 1- S- 10- C- 25- ﹡ ﹡ 31 ﹡ 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 1- Piston pump, variable displacement 2- Maximum geometric displacement: 57= 57.4 cm3/r. (3.5 in3/r) 63= 62.7 cm3/r. (3.84 in3/r) 74 = 73.7 cm3/r. (4.5 in3/r) 81= 81 cm3/r. (4.9 in3/r) 98= 98.3 cm3/r. (6.0 in3/r) 106= 106.5 cm3/r. (6.5 in3/r) 131= 131.1 cm3/r. (8.0 in3/r) 141= 141 cm3/r. (8.64 in3/r) 3- Design /
Eaton Vickers 42135-U 3525VQ35A12-1DA20 Tandem Hydraulic Pump
Eaton Vickers VQ Series High Speed, High Presure Pumps Features * Design In all pumps, except the rear pump of triple pumps, fluid flow is developed in a cartridge which consists principally of a cam ring, rotor, ten vanes, and unique side plates and support plates. The bimetallic flexible side plates are loSAARed on each side of the rotor with their bronze face toward the rotor and their steel face toward the support plate. Two cavities in each support plate hold high
432659-3 4535VQ60A38-11CC20 Eaton Vickers Tandem Hydraulic Pump
Eaton Vickers VQ Series High Speed, High Presure Pumps Features * Design In all pumps, except the rear pump of triple pumps, fluid flow is developed in a cartridge which consists principally of a cam ring, rotor, ten vanes, and unique side plates and support plates. The bimetallic flexible side plates are loSAARed on each side of the rotor with their bronze face toward the rotor and their steel face toward the support plate. Two cavities in each support plate hold high
Eaton Vickers 02-346207 PVH57C-RF-1S-11-C25VT4-31 Variable Axial Piston Pump Old Version
Eaton Vickers PVH Variable Axial Piston Pump Old Version PVH- 98- QI- C- R- ﹡ F- 1- S- 10- C- 25- ﹡ ﹡ 31 ﹡ 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 1- Piston pump, variable displacement 2- Maximum geometric displacement: 57= 57.4 cm3/r. (3.5 in3/r) 63= 62.7 cm3/r. (3.84 in3/r) 74 = 73.7 cm3/r. (4.5 in3/r) 81= 81 cm3/r. (4.9 in3/r) 98= 98.3 cm3/r. (6.0 in3/r) 106= 106.5 cm3/r. (6.5 in3/r) 131= 131.1 cm3/r. (8.0 in3/r) 141= 141 cm3/r. (8.64 in3/r) 3- Design /
709042-5 V2020-1F13B11B-1AA20-LH Eaton Vickers V2020 Series Double Vane Pump
Vickers V10/V20/V2010/V2020 Single and Double Vane Pumps Introduction * Series V10, V20, V2010, and V2020 fixed displacement pumps are of Vickers “balanced vane type” construction. V10 and V20 single pumps have rated flow capacities of 1 to 7 USgpm and 6 to 13 USgpm, respectively. Double pumps provide a single power source capable of serving two separate hydraulic circuits, or of providing greater volume through the combined delivery of both sections. In either type of
850357-5 V2020 -1F13B11B -1AA30 LH Eaton V2020 Series Eaton Vickers Vane Pump Parts Fixed Displacement Hydraulic
Vickers V10/V20/V2010/V2020 Single and Double Vane Pumps Introduction * Series V10, V20, V2010, and V2020 fixed displacement pumps are of Vickers “balanced vane type” construction. V10 and V20 single pumps have rated flow capacities of 1 to 7 USgpm and 6 to 13 USgpm, respectively. Double pumps provide a single power source capable of serving two separate hydraulic circuits, or of providing greater volume through the combined delivery of both sections. In either type of
421555-4 35VQ30A-1D20 Eaton Vickers Type 35VT Single Vane Pump
Eaton Vickers Single Vane Pumps 35V - 35VT - 35VQ - 35VQT - 35VQH Vickers 35V series vane pumps have been made in several designs for many years in various appliSAARions. Features and Benefits • High operating pressure capabilities in compact packages provide high power to weight ratios and lower installed costs. • Low noise characteristics inherent in intravane design enhance operator comfort. • Twelve vane system provides low amplitude flow pulsations resulting in low system
295913-4 50V109A-1D11-130 Eaton Vickers Single Vane Pumps V Series Low Noise Vane Pumps
Eaton Vickers Single Vane Pumps V Series - Low Noise Vane Pumps 20V, 25V, 35V, 45V, 50V Features and Benefits • High operating pressure capabilities in compact packages provide high power to weight ratios and lower installed costs. • Low noise characteristics inherent in intravane design enhance operator comfort. • Twelve vane system provides low amplitude flow pulsations resulting in low system noise characteristics. • Hydraulic balancing, designed to prevent internally
Eaton Vickers 709042-5 V2020-1F13B11B-1AA20-LH V2020 Series Double Vane Pump
Vickers V10/V20/V2010/V2020 Single and Double Vane Pumps Introduction * Series V10, V20, V2010, and V2020 fixed displacement pumps are of Vickers “balanced vane type” construction. V10 and V20 single pumps have rated flow capacities of 1 to 7 USgpm and 6 to 13 USgpm, respectively. Double pumps provide a single power source capable of serving two separate hydraulic circuits, or of providing greater volume through the combined delivery of both sections. In either type of
Eaton Vickers 02-334574PVB15-FRSY-40-CM-11 Axial Piston Pumps
Eaton Vickers PVB5/PFB6/PFB5/PVB10/PVB15/PVB20/PVB29/PVB45 Axial Piston Pumps Fixed and Variable Displacement PFB 5, PFB 10, PFB 20 PVB 5/6, PVB 10/15, PVB 20/29, PVB 45 and PVB 90 to SAE PVB 5/6, PVB 10/15, PVB 20/29 to DIN/ISO 3019 Features Operating pressure up to 210 bar (3000 psi) Model with compensator control “C” or “CM” Displacement from 10,5 to 197,5 cm3/r (0.64 to 12 in3/r) Speed up to 1800 r/min Variable displacement models make up this range of axial piston pumps.
02-335097 PVH98QIC-RAF-13S-11-C25VT4-31 Eaton Vickers Variable Axial Piston Pump
Eaton Vickers PVH Variable Axial Piston Pump Old Version PVH- 98- QI- C- R- ﹡ F- 1- S- 10- C- 25- ﹡ ﹡ 31 ﹡ 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 1- Piston pump, variable displacement 2- Maximum geometric displacement: 57= 57.4 cm3/r. (3.5 in3/r) 63= 62.7 cm3/r. (3.84 in3/r) 74 = 73.7 cm3/r. (4.5 in3/r) 81= 81 cm3/r. (4.9 in3/r) 98= 98.3 cm3/r. (6.0 in3/r) 106= 106.5 cm3/r. (6.5 in3/r) 131= 131.1 cm3/r. (8.0 in3/r) 141= 141 cm3/r. (8.64 in3/r) 3- Design /