Low Smoke Zero Halogen Power Cable
LSZH Class 2 Copper Conductor XLPE MV Cable IEC 60502 three cores
Detailed Product Description What is LSOH Power Cable Typical structure of LSOH flame-retardant cable: non-metallic cable cladding material is LSOH flame-retardant material with different properties. This structure enables the cable to pass class A tests in IEC 60332-3-22 and related tests in IEC 60754 and IEC 61034. Benefits of FR Cable When a fire occurs, the combustion of combustibles in the ordinary power
XLPE insulated LSZH sheath SWA power cable rated voltage 1KV
Detailed Product Description Standards International: IEC 60502, IEC 60228, IEC 60332, IEC 60754 China: GB∕T 12706.1-2008, GB∕T 19666-2005 Other standards such as BS,VDE and ICEA upon request Benefits of FR Cable When a fire occurs, the combustion of combustibles in the ordinary power system will produce a large amount of halogen-containing smoke. The LSOH power cable and the LSOH building materials used together
CU / XLPE / SWA / PVC Steel Tape Armour Power Cable Cu conductor XLPE Insulation
Detailed Product Description Benefits of FR Cable When a fire occurs, the combustion of combustibles in the ordinary power system will produce a large amount of halogen-containing smoke. The LSOH power cable and the LSOH building materials used together can effectively reduce the total amount of smoke released by combustible combustion and the content of halogen, so as to reduce the casualty rate
Cu/XLPE/CTS/ /LSOH 24kV steel tape armored power cable 3X120 mm2
Detailed Product Description Technical data Rated voltage: 12/20 kV Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions. Min. Ambient Temp.: The cable shall be pre heated if the ambient temperature is below 0℃ Min. Bending Radius: single core cable 20(d+D)±5% Multi-core cable 15(d+D)±5% Certificates CE, SGS, KEMA and more others at request
Underground MV power cable with cu/XLPE/CTS/LSOH/STA/LSOH rated voltage 12/20kV
Detailed Product Description Standards International: IEC 60502, IEC 60228, IEC 60332, IEC 60754 China: GB∕T 12706.2-2008, GB∕T 19666-2005 Other standards such as BS,VDE and ICEA upon request Note: Insulation identification as per standards or customer requirement Applications Laying in room ,tunnel ,cable trench ,and pipes. Constructions Conductor : Compact stranded copper conductor, Cl.2 as per
Underground MV power cable with cu/XLPE/CTS/LSOH/STA/LSOH rated voltage 8.7/15kV
Detailed Product Description Ordering Advice Rated Voltage Application Standard: IEC/BS/UL/GB Number of Cores Conductor Size & Construction Type of Insulation Armored or unarmored. If armor, the armor type & material The Requirement of Sheath Length of Cable & Packing Requirement Other Requirement Standards International: IEC 60502, IEC 60228, IEC 60332, IEC 60754 China: GB∕T 12706.2-2008, GB∕T
Single core and 3 cores CU/XLPE/CTS/STA/LSOH power cable rated voltage 6/10(12)kV
Detailed Product Description Applications Laying in room ,tunnel ,cable trench ,and pipes. Certificates CE, SGS, KEMA and more others at reques. Note: Insulation identification as per standards or customer requirement Standards International: IEC 60502, IEC 60228, IEC 60332, IEC 60754 China: GB∕T 12706.2-2008, GB∕T 19666-2005 Other standards such as BS,VDE and ICEA upon request Technical data
IEC60502.2 approval MV power cable with copper conductor XLPE insulation/STA/ LSOH sheath
Detailed Product Description Note: Insulation identification as per standards or customer requirement Applications Laying in room ,tunnel ,cable trench ,and pipes. Certificates CE, SGS, KEMA and more others at reques. Standards International: IEC 60502, IEC 60228, IEC 60332, IEC 60754 China: GB∕T 12706.2-2008, GB∕T 19666-2005 Other standards such as BS,VDE and ICEA upon request Technical
6/10 or 6.35/11KV double steel tape armored power cable with LSZH properties and cross section from 35~630mm2
Detailed Product Description Standards International: IEC 60502, IEC 60228, IEC 60332, IEC 60754 China: GB∕T 12706.2-2008, GB∕T 19666-2005 Other standards such as BS,VDE and ICEA upon request Technical data Rated voltage: 6/10 kV Maximum Conductor Temperature: under normal (90 ℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions. Min. Ambient Temp.
LSZH Class 2 Copper Conductor XLPE insulation and steel tape armored MV Cable IEC 60502 3 cores 300mm2
Detailed Product Description What is LSOH Power Cable Typical structure of LSOH flame-retardant cable: non-metallic cable cladding material is LSOH flame-retardant material with different properties. This structure enables the cable to pass class A tests in IEC 60332-3-22 and related tests in IEC 60754 and IEC 61034 . Benefits of FR Cable When a fire occurs, the combustion
1KV copper conductor XLPE insulation and LSOH sheath fixed application power cable
Detailed Product Description Constructions Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with BS EN 60228 Insulation : XLPE(cross-linked polyethylene) rated at 90 ℃ Interlining: LSOH Flame Retardant Polyolefin, black Armouring: STA(Steel-Tape Armouring) Sheath : LSOH Flame Retardant Polyolefin, black Certificates CE, SGS, KEMA and more others at request
CU / XLPE / STA / PVC Steel Tape Armour Power Cable Cu conductor XLPE Insulation
Detailed Product Description Note: Insulation identification as per standards or customer requirement Applications Laying in room ,tunnel ,cable trench ,and pipes. Product Description Designed for fixed power and control applications where mechanical protection is not required. Suitable for use indoors, outdoors or laid in concrete but not for direct burial or immersion in water LSZH cables
Low smoke and zero halogen flame retardant cable with Copper Conductor/mica tape/ XLPE Insulated /LSOH sheath
What is LSZH Cable? LSZH cable/wire refers to cables where the cable jacketing and insulation is made with materials that produce low/limited smoke and non-toxic halogens when exposed to fire or high temperatures. There is also low smoke cable and zero halogen cable / halogen free cable. Benefits of LSZH Cable Low smoke zero halogen cables are used when fire safety is critical, especially in enclosed spaces. A number of fires in transportation facilities and other locations