Hospital Air Sterilization
Alpha Clean Control System 5000 M3/H Hospital Air Sterilization
alpha clean control System Molecular sieve Hospital Air Sterilization Specifications: Technical parameters of MKJ4000-S4 Airflow rate 5000m3/h Klebsiella pneumoniae sterilization rate 100% Aspergillus Niger sterilization rate 100% Sterilization rate of Staphylococcus albus 100% Natural bacteria death rate 99.85% H3N2 influenza virus killing rate 99.99% Purification rate of PM0.5 for one pass 100% (on-site inspection) UV leakage intensity (at 30cm around the device) 0μw/cm2
Molecular Sieve 200m3 UVC Sanitizer Air Purifier
Molecular sieve realizes 100% isolation Hospital Air Sterilization Applications Main applications Respiratory unit, ICU, Emergency unit, Transplantation unit, CT room, Fever clinic unit, Blood wards, Burn wards, Neonatal rooms Environment Class I Laminar flow operation room/ward Environment Class II ICU/Hematological/Burn/Bone Marrow Transplant/Obstetric and Gynecologic/Catheter/Neonatal/Organ Transplant room/ward Environment Class III General/Pediatric/Rooming-in/Gynecologic
Rapid Sterilization UVC Lights HEPA Filter air disinfection purifier
rapid sterilization UVC lights HEPA filter Hospital Air Sterilization . α-Pure System technology · Remove 100% of white staphylococcus · Remove 100% of particles PM0.5 · Remove 99.99% of H3N2 viruses · Medical grade HEPA filtration plus UVC lights · Large CADR up to 1706.4 m3/h (1004 CFM) · Applicable room volume 100 m3 / 3531 ft3 at 20 ACH · Low Noise with low operating power · Strictly produced as per ISO standards · No harm and safety to human health · Easy to maintain and
Remove Bacteria Neonatal Room Air Purification Sterilizer
Remove bacteria Neonatal Room Molecular sieve Hospital Air Sterilization Used in a closed environment, suitable for places with a large number of people and strict requirements on the air environment . α-Pure System technology . Removes 100% of white staphylococcus . Removes 100% of particles PM0.5 . Removes 99.99% of H3N2 viruses . Medical grade HEPA filtration plus UVC lights . Large air flow rate up to 2941 CFM / 5000 m3/h . Applicable room volume 100 m3 / 3531 ft3 at 50
Hematology Department 100m3 Hospital Air Sterilization
LCD touch screen switch 100% Eliminating H3N2 Virus Hospital Air Sterilization Main applications :Respiratory unit, ICU, Emergency unit, Transplantation unit, CT room, Fever clinic unit, Blood wards, Burn wards, Neonatal rooms Classification of Environment MKJ4000-S2 Environment Class I (Indoor ACH≥50 times/h) ≤40 m3 Environment Class II (Indoor ACH≥20 times/h) ≤100 m3 Environment Class III (Indoor ACH≥10 times/h) ≤200 m3 Eliminating rates MKJ4000-S2 Eliminating rate of
Respiratory Department 500m3 Hospital Air Sterilization
hydrodynamics coordinate with high-energy photo ion Burn Department Air Sterilization Air Sterilization sterilization equipment for low immunity susceptible population, especially for leukemia newborn operating room transplant patients with burns intensive care and so on to provide clean, efficient and safe air barrier control medical air disinfection purifier is continuous dynamic safety factor for man-machine coexist in the world high efficiency good effective disinfection
HEPA Filter Membrane 1000 m3/h Hospital Air Sterilization
rapid sterilization HEPA filter membrane Hospital Air Sterilization Air capacity Model # MKJ4000-S1 Circulating air volume 1000 m3/h Antibacterial efficiency Classification of Environment MKJ4000-S1 Environment Class II (Indoor ACH≥20 times/h) ≤50m3 Environment Class III (Indoor ACH≥10 times/h) ≤100 m3 Eliminating rates MKJ4000-S1 Eliminating rate of Klebsiella pneumoniae (1h, 30m3 Experimental chamber), % 100% Eliminating rate of Aspergillus Niger (1h, 30m3 Experimental