EV Charger Parts
Overcurrent Overload Alarming DC40V EV Charger Parts Din Rail Meter With Antenna
Overcurrent Overload Alarming Din Rail Type DC Meter with Antenna 1.Overview: ● Shunt Sampling for DC Measuring ● 10~240A, 40~400VDC ● NB-IOT/ RS485 Communication Optional ● Over-current/voltage Alarm ● 4 Tariffs with 8 Time Slots ● Widely Used for telecommunication base station/solar power/EV charger/power generation system 2.Specification: Main Parameter Type Din Rail DC Measuring Device Reference voltage DC40V-400V Current 10~240A Operation temp. -20℃~+70℃ Accuracy class
Tou Multi Tariff Rates Direct Current Meter With RS485 IOT Communication
Tou Multi Tariff Rates Direct Current Meter with RS485 IOT Communication Notes:DC direct current meter, which is different from AC static meter. AC meter are common among the daily life. Din rail type energy meter is easy on assembly, and compact on size. Hence Din rail type DC meter is very hot due to these features. 1.Overview: ● Shunt Sampling for DC Measuring ● 10~240A, 40~400VDC ● Equipped with RS485 Communication ● Over-current/voltage Alarm ● 4 Tariffs with 8 Time
Open Core Wireless Mbus 100A Electric Current Sensor High Accuracy Current Sensor
100A Open Core Wireless M-bus Mbus Communication Current Sensor 1.Overview: ● Built-in Metrology & M-bus IC ● Max Measuring Current 100A ● Compact Size with Customized Design ● Stable Performance with Long Service Life ● Widely used for smart meter,smart grid,EV charger,monitoring device,circuit protection,machine equipment 2.Specification: Measuring Current Range 100A Accuracy Class Class 1 Temperature Accuracy 2℃ Frequency 50-60Hz Wiring Diameter ≤φ12mm Operation Temperatur
IEC 62955 PCB Cable 6mA DC Leakage Current Sensor for EV DC Charging Station
IEC 62955 PCB Cable 6mA DC Leakage Current Sensor for EV DC Charging Station Notes:Pins+Cable: Integrated with the above functions, serial port communication (UART) can be carried out, and the leakage current alarm value can be set autonomously, and can also output the switching control signal. The leakage current of AC and DC can be output alarm. 1.Overview: ● mA Level Measurement ● AC DC Leakage Data Readable ● Alarm Value Programmable, 3 alarm Outputs ● One-body Design,
Din Rail RS485 EV Charger Parts NB-IOT Bidirectional DC Energy Meter
Din Rail RS485 NB-IOT Bidirectional DC Energy Meter for Solar System PV Notes:NB-IOT & RS485 commmunication are the advantages of this direct current energy meter. They are prefectly to use with PV solar panel or energy storage system. 1.Main Features: ● Shunt Sampling for DC Measuring ● 10~240A, 40~400VDC ● NB-IOT/ RS485 Communication Optional ● Over-current/voltage Alarm ● 4 Tariffs with 8 Time Slots ● Widely Used for Base Station/Solar Power/EV charger 2.Technical
EV Charger 100A CT Split Core Current Transformer Class 1
EV Charger Parts 100A Split Core Current Transformer CT Smart Sensor with M-BUS 1.Overview: ● Built-in Metrology & M-bus IC ● Max Measuring Current 100A ● Compact Size with Customized Design ● Stable Performance with Long Service Life ● Widely used for smart meter,smart grid,EV charger,monitoring device,circuit protection,machine equipment 2.Specification: Measuring Current Range 100A Accuracy Class Class 1 Temperature Accuracy 2℃ Frequency 50-60Hz Wiring Diameter ≤φ12mm
IEC62752 IEC62752:2016 6mA DC Residual Current Detection Sensor For EV Battery Charger
IEC62752 IEC62752:2016 6mA DC Residual Current Detection Sensor For EV Battery Charger Notes: Type A leakage sensor: Type A leakage current improves the magnetic characteristics of the transformer, which can protect not only the sinusoidal leakage signal, but also the leakage signal containing the pulsating DC component. Type B leakage sensor: It can protect sinusoidal AC signal pulsating DC signal and smooth signal reliably, which has higher design requirements than type A
Form A 40A Dpdt Non Latching Relay On Solar Panels For Home Charging
Form A 40A Dpdt Non Latching Relay On Solar Panels For Home Charging Notes: Electromagnetic relay include power relay and latching relay, we can also say non latching relay and latching relay. Latching means the relay's contacts will hold the status even power off or no pulse. 1. Main Features: ● Continuous Current:40A ● Max. Switching Voltage:277VAC ● Rated Voltage:12VDC/24VDC ● Power Consumption:1.8W/3.0W ● Dielectric withstanding voltage of across open contact:4KVAC ● Cost
Contact Gap Dpdt Dpst 40 Amp Dpdt Relay For Solar Panel For Charging Cable
Contact Gap Dpdt Dpst 40 Amp Dpdt Relay For Solar Panel For Charging Cable Notes: IM-NE801 with contact distance of 3mm hence it can resist up to 4000Vac, As the EV charger factories are looking for 3mm 4mm contact gap relay due to 4Kvac & 6Kvac resistance. The solar panel factories are also looking for 40A 2 pole power relay for solar pumps. 1. Main Features: ● Continuous Current:40A ● Max. Switching Voltage:277VAC ● Rated Voltage:12VDC/24VDC ● Power Consumption:1.8W/3.0W ●
4000Vac 2A 40A Changeover Relay Solar Grid Relay For Ev Ac Charger
4000Vac 2A 40A Changeover Relay Solar Grid Relay For Ev Ac Charger Notes: IM-NE801 with contact distance of 3mm hence it can resist up to 4000Vac, As the EV charger factories are looking for 3mm 4mm contact gap relay due to 4Kvac & 6Kvac resistance. 1. Main Features: ● Continuous Current:40A ● Max. Switching Voltage:277VAC ● Rated Voltage:12VDC/24VDC ● Power Consumption:1.8W/3.0W ● Dielectric withstanding voltage of across open contact:4KVAC ● Cost Efficiency & Surge
2 Group Dpdt Vs Spdt 40A Ac Relay Solar Energy Relay For Slow Charging
2 Group Dpdt Vs Spdt 40A Ac Relay Solar Energy Relay For Slow Charging Notes: IM-NE801 with 2 groups of contacts, the switching current is 40A. It was widely used for 32A AC slow charging and 40A solar pumps 1. Main Features: ● Continuous Current:40A ● Max. Switching Voltage:277VAC ● Rated Voltage:12VDC/24VDC ● Power Consumption:1.8W/3.0W ● Dielectric withstanding voltage of across open contact:4KVAC ● Cost Efficiency & Surge Protection ● Contact Form:2A/2B ● Compact Size:49
1.8W 3.0W 2 Channel Dpdt A Spdt 40A Relay Wiring Solar Dc Relay
1.8W 3.0W 2 Channel Dpdt A Spdt 40A Relay Wiring Solar Dc Relay Notes: Dual-way Relay, means DPDT ,2 Channel or 2 Phase relay The relay contact form can be 2A or 2B ,that is normally open and normally close 1. Main Features: ● Continuous Current:40A ● Max. Switching Voltage:277VAC ● Rated Voltage:12VDC/24VDC ● Power Consumption:1.8W/3.0W ● Dielectric withstanding voltage of across open contact:4KVAC ● Cost Efficiency & Surge Protection ● Contact Form:2A/2B ● Compact Size:49
12Vdc 24Vdc 40A Relay 12V Relay Solar Panel For Solar Rooftops
12Vdc 24Vdc 40A Relay 12V Relay Solar Panel For Solar Rooftops Notes: In order to protect the environment, the world is vigorously developing the new energy industry, and the AC electric vehicle charging pile market is under hot development. If you are not in this era, or you are involved in the new energy electric vehicle industry, or you are already considering the internal parts of the existing charging pile to modify. This is all great news. IVY introduces the new energy
100A Class Clamp Split Core Current Sensor For EV Charger
High Accuracy Class Clamp Split Type Current Sensor for EV Charging Plug Home Charger Notes:This open core current sensor uses ferrite with high magnetic conductivity as the magnetic conducting material.It has high precision, stable performance, small volume, convenient installation, no rust at the opening and other sex points. Suitable for current and temperature measurement and monitoring, and with M-BUS communication function. Open and close design structure, under the
IEC61851 High Accuracy Integrated Leakage Detection VAC Residual Current Sensors
IEC61851 High Accuracy Integrated Leakage Detection VAC Residual Current Sensors NotesThe AC DC leakage current sensor is installed on the positive and negative output lines of the AC or DC circuit. When the device is in operation, it can detect the output signals of each branch sensor in real time. When the branch insulation is normal, the current flowing through the sensor is equal in magnitude and opposite in direction, and its output signal is zero. When the branch is
6mA DC Fault Current Detection Leakage Sensor for Electric Vehicle Charging Station
6mA DC Fault Current Detection Leakage Sensor for Electric Vehicle Charging Station Notes:Pins+Cable: Integrated with the above functions, serial port communication (UART) can be carried out, and the leakage current alarm value can be set autonomously, and can also output the switching control signal. The leakage current of AC and DC can be output alarm. 1.Overview: ● mA Level Measurement ● AC DC Leakage Data Readable ● Alarm Value Programmable, 3 alarm Outputs ● One-body
EV Charging Components IEC61851 Certified 6mA 30mA DC AC Leakage Current Sensor
EV Charging Components IEC61851 Certified 6mA 30mA DC AC Leakage Current Sensor for Public Charging Notes: Type A leakage sensor: Type A leakage current improves the magnetic characteristics of the transformer, which can protect not only the sinusoidal leakage signal, but also the leakage signal containing the pulsating DC component. Type B leakage sensor: It can protect sinusoidal AC signal pulsating DC signal and smooth signal reliably, which has higher design requirements
IEC62955:2018 Complaint Leakage Current Transformer AC DC Current Sensor for EV Charger
IEC62955:2018 Complaint Leakage Current Transformer AC DC Current Sensor for EV Charger Notes:Different markets have different needs. AC DC Leakage sensor for Vietnamese market, the pin-mounted AC DC leakage sensor is relatively more common, especially for the charging pile is undoubtedly the best choice. It can accurately detect the mA level of electricity.In addition, Germany may prefer the installation method of cable only, and AC DC leakage sensors are also popular in
IEC 62752 Standard SMD Footprint AC DC Leakage Current Sensor for EV Portable Charger
IEC 62752 Standard SMD Footprint AC DC Leakage Current Sensor for EV Portable Charger NotesThe AC DC leakage current sensor is installed on the positive and negative output lines of the AC or DC circuit. When the device is in operation, it can detect the output signals of each branch sensor in real time. When the branch insulation is normal, the current flowing through the sensor is equal in magnitude and opposite in direction, and its output signal is zero. When the branch
Flame Retardant EV Charger Parts 5W 12V Switching Power Supply Module
EV Components Input Voltage 85-450VAC 5W 12V AC DC Switching Power Supply Module Notes:The power supply module, also called modular power supply, is a "building block" produced by power supply manufacturers based on the prediction of large-scale market demand. Its advantage is that if you need to buy an AC/DC converter or DC/DC converter or need to customize it from scratch One that is fully compatible with the equipment. With the AC DC and DC DC power supply module, such as