Differential Pressure Gauge
Dwyer 2300-1KPA,2300-2KPA,2300-2.5 KPA,2300-4KPA Differential Pressure Gauge MAGNEHELIC
Dwyer 2300-1KPA,2300-2KPA,2300-2.5 KPA,2300-4KPA Differential Pressure gauge MAGNEHELIC 2000-60PA ,0-60Pa, 2300-120PA,0-±60Pa, 2000-125PA0,-125Pa, 2300-250PA,0--±125Pa, 2000-125PA,0-250Pa, 2300-500PA,0-±250Pa, 2000-500PA,0-500Pa, 2000-750PA,0-750Pa 2300-1KPA, 2300-2KPA, 2300-2.5 KPA, 2300-4KPA
Dwyer BT Bimetal Thermometer BTB22551 BTB2405D BTB2409D
Dwyer BT Bimetal Thermometer BTB22551 BTB2405D BTB2409D Features Hermetically sealed Adjustable dial position models The Series BT Bimetal Thermometers offer accurate, reliable service even in the toughest environments. These corrosion resistant units are constructed from stainless steel and are hermetically sealed to prevent crystal fogging. The bimetal element directly drives pointer, eliminating gears and linkage. An external reset screw allows field calibration and easy
Dwyer Series 616KD Series Differential Pressure Transmitter 616KD-B-54
Dwyer Series 616KD Series Differential Pressure Transmitter 616KD-B-54 The Series 616KD Differential Pressure Transmitters with One-Touch® Digital Push- Button Calibration Technology are designed for simplicity, making them the ideal choice for installers and maintenance professionals. These instruments not only alleviate cumbersome turn pots typically found in most transmitters, but eliminate entirely the need to span the instruments during calibration. With a single digital
Dwyer Differential SPDT Pressure Switch DXW-11-153-1/ DXW-11-153-2/ DXW-11-153-3/ DXW-11-153-4
Dwyer Differential SPDT Pressure Switch DXW-11-153-1 DXW-11-153-2 DXW-11-153-3 DXW-11-153-4 Series DX Wet/Wet Differential Pressure Switch NEMA 4X Enclosure, Low Differential Set Points The Series DX Wet/Wet Differential Pressure Switch makes a contact output based on the differential between two pressure sources. Wetted materials of brass and fluoroelastomer are suitable for use with most gases and water based solutions. The switch can be used for low differential pressure
Yokogawa CPU Module SCP451-51-S1 Process Module
Yokogawa CPU Module SCP451-51-S1 Process Module The module is widely used in the field of industrial automation, including but not limited to petroleum, chemical, electric power, metallurgy and other industries. Suitable for industrial automation systems requiring high precision and high stability control.
Dwyer Pressure Switch A3000-250PA Pressure Gauge Range 0-250 Pa
Dwyer Pressure Switch A3000-250PA Pressure Gauge range 0-250 Pa Product Applications Air Conditioning Systems Clean Rooms Fume Exhaust Systems 3-in-1 Indicating Gage, Lo-limit and Hi-limit Control A3000-250PA Pressure switch/gage, range 0-250 Pa.
Original Dwyer 485B THERMO-HYGROMETER Dwyer 485B-1
Original Dwyer 485B THERMO-HYGROMETER Dwyer 485B-1 Measures % RH, Temperature, Dew Point and Wet Bulb Features Compatible with Dwyer AP1 thermo-anemometer and VP1 100 mm vane thermoanemometer probes (sold separately) Hold feature to freeze current readings on the display Stores up to 99 readings for future evaluation Model Description 485B-1 Digital thermo-hygrometer includes 9V battery, sensing probe, wrist strap, hard carrying case and instructions
Dwyer Explosion-proof Differential Pressure Switch 1950G-0-B-120-NA 1950G-00-B-240
Dwyer Explosion-proof Differential Pressure Switch 1950G-0-B-120-NA 1950G-00-B-240 Explosion-proof, Weatherproof, Compatible with Natural Gases Features Compatible with natural gas External set point screw provides easy access that simplifies making adjustments without opening or disassembling enclosure Easily accessible electrical connection simplifies the installation
Dwyer U-Tube Manometer 1223-M1000-W/M Rang 500-0-500 Mm W.c.
Dwyer U-Tube Manometer 1223-M1000-W/M Rang 500-0-500 mm w.c. Suitable for Pressures up to 100 psi, Better Precision Duct static pressure Calibration labs Filter monitoring Model Description 1221-12-W/M U-tube manometer, range 6-0-6" w.c. 1221-16-W/M U-tube manometer, range 8-0-8" w.c. 1221-20-W/M U-tube manometer, range 10-0-10" w.c. 1221-24-W/M U-tube manometer, range 12-0-12" w.c. 1221-36-W/M U-tube manometer, range 18-0-18" w.c. 1221-8-W/M U-tube manometer, range 4-0-
Dwyer DIFFERENTIAL PRESSURE GAGES 2301-HA-SS MAGNEHELIC
Dwyer DIFFERENTIAL PRESSURE GAGES 2301-HA-SS MAGNEHELIC Model Description 2301 Differential pressure gage, range 0.5-0-0.5" w.c., minor divisions .02. Filter Monitoring Air Velocity with Dwyer Pitot Tube Blower Vacuum Monitoring Fan Pressure Indication Duct, Room or Building Pressures Clean Room Positive Pressure Indication
Huba Control 501.931003141 Water Pipe Pressure Transmitter 0-16 Bar Sensor
Medium Liquids and gases Pressure range -1 ... 0 - 60 bar Output ratiom. 10% ... 90% 0 ... 5 V 1 ... 6 V 0 ... 10 V 4 ... 20 mA Accuracy < 0.5% fs Electrical connection Cable 1.5 m Connector DIN EN 175301-803-A or C M12x1 Pressure connection Inside thread or outside thread
2-wire Output Type NJ1 5-8-N-Y18812 Inductive Sensor With Special Adjustment And 1.5 Mm Rated Operating Distance
General specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance 1.5 mm Installation flush Assured operating distance 0 ... 0.97 mm Reduction factor rAl 0.4 Reduction factor rCu 0.3 Reduction factor r304 0.85 Output type 2-wire Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 2000 Hz Hysteresis 0.1 mm Current consumption Measuring plate not detected min. 2.5 mA Measuring plate detected ≤ 1.2 mA Functional safety related
UNI T UTi120MS Thermal Camera For IPhone IOS , Infrared Cameras Thermal Imaging , 120X90 IR Resolution,Thermal Imager,-4°F~1022°F Temperature Range,25Hz Frame Rate,Support Video Recording
Technical Data IR resolution (Pixels) 120×90 Field of view(FOV) 50°×38° Thermal sensitivity(NETD) ≤60mK @25℃ Spatial resolution(IFOV) 7.3mrad Frame rate ≤25Hz Spectral range 8~14µm Focus Focus free Lens focal length 2.28mm Temperature measurement range -20℃ ~ 400℃ Accuracy ±2℃ or ±2% whichever is greater Emissivity 0.01~1.00 adjustable (0.95 default) Functions Color palettes 7 (White hot, Lava, Ironbow,Black hot, Red hot, Rainbow, Rainbow HC) Image modes Thermal,Fusion,PIP On
Good Gas Detector MSA 5X 4X 4RX 2X Multigas Detector LEL O2 CO/H2S SO2 CO/NO2 CO For Workplace Safety
customized support OEM, ODM place of origin China warranty 1 years brand name - model number 4XR power POWER material PVC Model Number: 5X Warranty: 1 year Operating Temperature: -40℃~60℃ Place of Origin: USA Dimensions: 6.68 x 3.52 x 1.95 inches Style: LEL, O2, CO, H2S, HCN (Color, Instrument/Line/Probe) Usage Other
Megger MIT1025-UK Insulation Tester With Output, 20 Teraohms Resistance , 10kV Multi-Range Test Voltage
100% New Original Only Basic Grade Electronic Refrigerant Meter Weight 2424 G
Intelligent basic level electronic refrigerant meter The Smart Basic level electronic refrigerant watch band has two temperature compensated pressure sensors to accurately measure high and low end pressure, and the App allows you to easily read the measurement data on the smart device, complete and send the measurement report in the field. List of refrigerants in the instrument. Suitable for refrigeration system and heat pump system repair, maintenance and commissioning. The
New Digital Auto Car Paint Thickness Tester Coating Thickness Gauge With Led Flashlight
Digital Auto Car Paint Thickness Tester Min diameter 12mm Min thickness 0.5mm Weight 109g Operating temperature range -20~40℃
Absolute And Gauge Pressure Cerabar PMP51PMP71B Pressure Transmitter PMP71-1BA1
Pressure transmitter with ceramic and metal sensors • Very good reproducibility and long-term stability • High reference accuracy: up to 0.075%, as PLATINUM version: 0.05% • Turn down 100:1, higher on request • Used for process pressure monitoring up to SIL3, certified according to IEC 61508 by TÜV SÜD • HistoROM®/M-DAT memory module • Function-monitored from the measuring cell to the electronics • Continuous modularity for differential pressure, hydrostatic and pressure
Original FMB50-2ED10 Ultrasonic Level Transmitter FMP55 FMI51 FMP52 FTL51C In Stock
Ultrasonic level transmitter Operational safety and process safety: • Alternative monitoring measures must be taken to ensure operational safety and process safety during confiugration, testing and maintenance work on the device. • The device is safely built and tested according to state-of-the-art technology and has left the factory in perfect condition as regards technical safety. The applicable regulations and European standards have been taken into account. • Pay
100% New Original Germany 4-channel Transmitter Liquiline Cm444
Multi-parameter transmitter Multiparameter transmitter with a maximum of eight measuring channels based on digital Memosens technology. Extensible multiparameter controller for monitoring and controlling processes in industry and the environmental sector. Measuring range 0-14 PH Weight 17kg Type Ph Transimitter