Differential Pressure Gauge
AVP100-H| Azbil|Smart Valve Positioner 100 Series
Lanyi MR9272E Handheld Process Calibrator with 0.1% Accuracy Multi-Signal Support and Field-Ready Design
Multi-Signal Support: Simultaneously measures and outputs multiple signal types including 4-20mA current, 0-10V voltage, frequency, millivolts, and resistance. Sensor Calibration: Supports direct simulation and reading of thermocouples and thermal resistances, including PT100 and PT1000 sensors. Advanced Protocols: Models often feature HART and MODBUS capabilities for deeper communication with smart industrial devices. Field-Ready Design: Housed in a durable shell with a high
Norgren 11-808-980 pilot pressure regulator, G1, without gauge
Medium Compressed air Operating Temperature -20 ... 80 °C, -4 ... 176 °F Port Size G1 Gauge Port Rc1/8 Adjustment Air pilot operated Maximum Inlet Pressure 20 bar, 290 psi Outlet Pressure Adjustment 0.3 ... 19 bar, 4 ... 275 psi Relieving/Non-Relieving Relieving Flow 180 dm3/s, 381 scfm Materials - Body Zinc alloy Materials - Bonnet Aluminium alloy Materials - Elastomers Nitrile rubber (NBR) Dimensions - Height 125 mm Dimensions - Length 106 mm Dimensions - Width 125 mm
Dwyer 641RM-6 Dwyer Air velocity transmitter with 6 ft cable, no display
Dwyer 641RM-6 Air velocity transmitter with 6 ft cable, no display Air Velocity Transmitter w/ Remote Heated Probe for HVAC & Clean Rooms The Dwyer Series 641RM Air Velocity Transmitter utilizes heated mass flow sensor technology to measure air velocity in HVAC systems and clean rooms. The series is intended for use with clean, dry air and compatible, non-combustible gases.
Differential Pressure Switch 50~5000pa Waterproof Heating Ventilation Furnace Vent Air Pressure Switch
Max. Working Pressure 5000PA Media Water, Air Max. Voltage 250v Material Plastic, Brass, Aluminum alloy, Copper Accuracy Class ±0.1% FS Contact Arrangement SPDT Max. Current 1.5A Application Pressure Control Whether The Smart No Place of Origin Zhejiang, China Model Number LF32 Brand Name LEFOO Product Name Pressure switch Pressure range 20-200Pa;30-300pa;100-1000pa;1000-5000pa Power supply 250V Medium Air, non-combustible and ono-aggressive gass Electrical rating 250VAC/1.5A
Original Germany JUMO 404366/000 Pressure Transmitter IP65 High Precision Piezoresistive Pressure Transducer
Key attributes accuracy 0.01% FS Protection Class IP65 warranty 1 Year customized support OEM place of origin China brand name jumo material stainless steel OUTPUT 4-20mA Packaging and delivery Selling Units Single item Single volume 0 cm³
PG POWER-GENEX Electro-pneumatic Positioner EPL-DB2SN7LN
Key attributes Valve type Ball Valve customized support OEM warranty 1 YEAR place of origin China model number EPL-DB2SN7LN brand name PG-POWER-GENEX Input Signal 4~20mA DC Air Supply Max. 7.0bar Ambient Temperature -40 ~ +70℃ Pressure Gauge Stainless steel Output Characteristics Linear
Yokogawa ZR22G Zirconia Oxygen/Humidity Analyzer
1. In-Situ Direct Measurement Principle (Core Advantage) No complex gas sampling system required; insert probe directly into duct/furnace to measure hot flue gas continuously. Solid zirconia cell sensing principle, supports dual measurement modes: oxygen concentration & high-temperature vapor humidity. Ultra-fast response: 90% value reached within 5 seconds, ideal for real-time combustion closed-loop controlYokogawa E.... Wide measuring range: O₂: 0.01 ~ 100 vol% H₂O vapor: 0
UNI-T UT373 Is a Reliable Digital Non-contact Tachometer
1. Product Overview The UNI-T UT373 is a compact handheld laser digital tachometer designed for non-contact rotational speed testing of motors, fans, spindles, conveyor rollers and automotive rotating components. It adopts laser photoelectric sampling technology with reflective tape for stable RPM reading, supporting dual measurement modes: rotational speed (RPM) and revolution counter. Featuring mini lightweight body, high precision and complete practical functions, it is
CJ1W-IC/II Expand CJ/NJ-series with These Units
New Original Three-Phase Power Quality Analyzers Fluke 1775 In Stock
Specifications: Fluke 1770 Series Three-Phase Power Quality Analyzers Key features Voltage inputs Number of inputs 4 inputs, 3 phases and neutral referenced to PE (5 connectors) Measurement category 1000 V CAT III / 600 V CAT IV Maximum input voltage 1000 V rms / 1000 V dc (1700 Vpk) Nominal voltage range Wye and single phase: variable (50 V – 1000 V)Delta: Variable (100 V – 1000 V)IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin ) 100 V – 690 V Input
Original and New FS24X FS20X Series Detectors FS20X-211-24-3 FS20X-211-23-3 WiTH Good Price
Key attributes warranty 1year customized support OEM, ODM place of origin usa color - power - brand name - material Stainless steel
wika Bourdon Tube Pressure Gauges Models 233.53, 232.53 Stainless Steel Series
With liquid filled case for applications with high dynamic pressure pulsations or vibration Suitable for corrosive environments and gaseous or liquid media that will not obstruct the pressure system Process industry: chemical/petrochemical, power stations, mining, on and offshore, environmental technology, mechanical engineering and plant construction Accuracy class 2” & 2½”: ± 2/1/2 % of span (ASME B40.100 Grade A) 4”: ± 1.0 % of span (ASME B40.100 Grade 1A)
IMI Norgren 18-015 Series 18-015-209 18-015-211 18-015-204 Pressure Gauge, 0-160 PSI,1/4 NPT center back port
Medium - Compressed air, oil and gases or liquids which do not corrode copper alloys North American Port Sizes - 1/8 & 1/4 NPT Conform to BS EN 837-1:1998 Back or bottom connection
OMRON Network Module CJ1W-NC434
Rated Voltage 52 V, 12 V, 220 V, 24 V, 110 V, 5 V Rated Current 10A, 12 A, 16 A, 18 A Material other Feature Durable, Lightweight, Eco-Friendly, Flexible, High Efficiency, Waterproof, Safety Model Number CJ1W-NC434 Place of Origin Japan Brand Name OMRON
Dwyer MARK II M-700PA Molded Plastic Manometer 10-0-700 Pa Inclined Vertical with Red Fluid
Dwyer MARK II M-700PA molded plastic manometer offers precise 10-0-700 Pa range for air velocity, filter, and paint booth monitoring. Durable inclined-vertical design with red fluid ensures clear readings. Reliable for industrial HVAC and B2B applications.
Dwyer Magnetic Differential Pressure Gauge 0-750 Pa 2% Accuracy Model 2000
Dwyer Model 2000 magnetic differential pressure gauge offers ±2% accuracy across ranges up to 1000 Pa. Ideal for HVAC, clean rooms, and filter monitoring. Lightweight 0.7 kg design with magnetic coupling for durability. CE certified, reliable delta pressure measurement.
6DR5020-0NG00-0AA0 SIPART PS2 Electropneumatic Positioner
Product Description
New Original Fluke 381 True RMS AC/DC Clamp Meter with 999.9 A Range and Remote Display
Electrical Specifications AC Current via Jaw Range 999.9 A Resolution 0.1 A Accuracy 2% ± 5 digits (10-100 Hz) 5% ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz) 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2% for C.F. > 2 AC Current via Flexible Current Probe Range 999.9 A / 2500 A (45 Hz – 500 Hz) Resolution 0.1 A / 1 A Accuracy 3% ± 5 digits Crest Factor (50/60 Hz) 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 Position Sensitivity Distance from Optimum i2500-10
Kyoritsu KEW 4106 EARTH RESISTANCE & RESISTIVITY TESTER
Function Range Resolution Measuring range Accuracy Earth resistanceRe(Rg atρ measurement) 2Ω 0.001Ω 0.03 to 2.099Ω ±2%rdg±0.03Ω 20Ω 0.01Ω 0.03 to 20.99Ω ±2%rdg±5dgt (*1) 200Ω 0.1Ω 0.3 to 209.9Ω 2000Ω 1Ω 3 to 2099Ω 20kΩ 10Ω 0.03 to 20.99kΩ 200kΩ 100Ω 0.3 to 209.9kΩ Auxiliary earth resistanceRh, Rs 8% of Re+Rh+Rs Earth resistivityρ 2Ω 0.1 to 1Ω·mAuto-ranging 0.2 to 395.6Ω·m ρ=2×π×a×Rg (*2) 20Ω 0.2 to 3956Ω·m 200Ω 20 to 39.56kΩ·m 2000Ω 0.2 to 395.6kΩ·m 20kΩ 2.0 to 1999kΩ·m 200kΩ