In Vitro Diagnostic Reagents
Clinical reagent kit D-Dimer for Automatic immunoassay analyzer in Cardiac Marker
CLIA Reagents of Inflammation (D-Dimer) 【Expected usage】 This product is used to quantitatively detect the content of D-dimer (D-Dimer) in human plasma in vitro. D-dimer is a specific degradation product produced by plasmin hydrolysis after fibrin monomer is cross-linked by activating factor XIII. It is a specific marker of fibrinolysis process. D-dimers are derived from cross-linked fibrin clots lysed by plasmin. The fibrinolytic system is the most important anticoagulant
Diagnostic reagent kit Procollagen Ⅲ N Terminal Peptide(PⅢNP) for Automatic immunoassay analyzer in Hepatic Fibrosis
CLIA Reagents of Inflammation (PⅢNP) PIIINP is an amino-terminal tail peptide that enters the blood circulation after being cleaved by related enzymes before PCIII forms procollagen outside the cell. Intact PIIINP is mainly cleared through endocytosis mediated by sinusoidal endothelial cell receptors. Therefore, when collagen metabolism is active and liver function is damaged, serum PIIINP increases, and PIIINP is regarded as a serological indicator of liver fibrosis. The
50/100 Test Kit(Angiotensin II- human) for Automatic immunoassay analyzer in Hypertension
CLIA Reagents of Hypertension (Angiotensin II- human) Angiotensin II is a polypeptide substance produced by the hydrolysis of angiotensin I under the action of angiotensin-converting enzyme. Angiotensin receptors are present in vascular smooth muscle, cells of the adrenal cortex, and cells in some parts of the brain, heart and kidney organs. Angiotensin II binds to angiotensin receptors, causing corresponding physiological effects, including (1) constricting systemic
Chemiluminescence reagent kit Hepatitis B c Antibo(HBcAb) for Automatic immunoassay analyzer in Infectious Disease
CLIA Reagents of Inflammation (HBcAb) Antibody class Anti-HBc can be divided into three types: anti-HBcIgM, anti-HBcIgA, and anti-HBcIgG. These types appear and disappear in sequence in HBV infection. Only the IgG type can exist for a long time. In the test sheet reported by the laboratory, if only "anti-HBc" is marked and there is no type, then it should be the sum of these three types, but most hospital laboratories report IgM and IgG type II. Anti-HBclgM type, called
Infectious disease kit Hepatitis C Virus Antibody(Anti-HCV) for Automatic immunoassay analyzer in Infectious Disease
CLIA Reagents of Inflammation (Anti-HCV) Hepatitis C Virus Antibody (Anti-HCV) in human serum. The test has to be performed on the CIA fully auto analyzer (Including CIA 600, CIA 1200, CIA 1800). Hepatitis C virus antibody Kit (CLIA) (hereinafter referred to as Anti-HCV) is used for the in vitro qualitative detection of Anti-HCV which is mainly for adjuvant treatment of hepatitis C HCV is spherical, with diameter less than 80nm (in hepatocytes: 36-40nm, in blood: 36-62nm). It
50/100 Tests Insulin (INS) for Automatic immunoassay analyzer in DIABETES In Vitro Diagnostic Reagents
CLIA Reagents of DIABETES (INS) Clinical Significance Determination of insulin can understand islet function and determine the type of diabetes. The blood insulin test is mainly suitable for patients who are not using insulin treatment. It can be measured by drawing blood on an empty stomach and 2 hours after a meal. Under normal circumstances, the fasting insulin level should be 10-25mU/dL, and the postprandial level should be 4 higher than the fasting level. -5 times. If
chemiluminescence immunoassay C-Peptide (CP) for Automatic immunoassay analyzer in DIABETES
CLIA Reagents of DIABETES (CP) 【expected usage】 For in vitro quantitative detection of C-peptide (C-P) in human serum. C-Peptide (C-P) is a connecting peptide connecting insulin A chain and B chain in the proinsulin molecule. It consists of 31 amino acid residues to form a connecting peptide with a molecular weight of 3021. Proinsulin is cleaved in the pancreas by proteases and carboxypeptidases to generate one molecule of insulin and one molecule of C-peptide. C-peptide has
Assayed reagent kit Anti human insulin antibody(INS-Ab) for Automatic immunoassay analyzer in DIABETES
Assayed reagent kit Anti human insulin antibody(INS-Ab) for Automatic immunoassay analyzer in DIABETES Project Introduction Insulin antibody (INS-Ab): Insulin antibodies appear in two cases: one is the drug antibody (IA) produced by insulin therapy in patients receiving exogenous insulin treatment, which is mainly related to the purity of insulin preparations; one These are called insulin autoantibodies (IAAs) in patients who have never been treated with insulin. The two
Solution Reagent Kit PROG Fertility Hormone Progesterone Immunoassay Reagents POCT Born for IVD Emergency
Solution Reagent Kit PROG Fertility Hormone Progesterone Immunoassay Reagents POCT Born for IVD Emergency KIT COMPONENTS Reagent Integral for 100 determinations Magnetic beads: TRIS buffer, magnetic beads complex binding with goat anti-FITC, buffer with BSA 1×3mL Calibrator A-F: BSA buffer with different levels of P antigen 6×0.3mL P Anti A: P Antibody complex labeled FITC, containing buffer with BSA 1×3mL P Anti B: P Antigen complex labeled by AP, containing buffer with BSA
Serum/Plasma/Whole Blood Test Estradiol Reagent kit E2 for Fertility Hormone In Vitro Diagnostic Reagents
Serum/Plasma/Whole Blood Test Estradiol Reagent kit E2 for Fertility Hormone In Vitro Diagnostic Reagents KIT COMPONENTS Reagent Integral for 100 determinations Magnetic beads: TRIS buffer, magnetic beads complex binding with goat anti-FITC, buffer with BSA 1×3.0 mL Calibrator A-G: BSA buffer with different levels of E2 Antigen 7×0.3 mL E2 Anti A: E2 derivative labeled by FITC, containing buffer with BSA 1×6.0 mL E2 Anti B: E2 Antibody complex labeled AP, containing buffer
Kidney Function Reagent+Calibrator+Quality Control H-ALB Assay Kits Chemiluminescence Immunoassay Reagents for IVD
Kidney Function Reagent+Calibrator+Quality Control H-ALB Assay Kits Chemiluminescence Immunoassay Reagents for IVD SPECIMEN COLLECTION Sample material: Serum/Plasma/Whole Blood Collect samples using standard procedures. Store at 2-8℃: 24 hours, for longer storage periods: freeze to below - 20℃ Avoid repeated freezing and thawing cycles, stored samples should be thoroughly mixed prior to use (Vortex mixer) CLIA Reagents of Kidney Function (H-ALB) Test Item H-ALB Luminescent
CE ISO13485 Bottle Diagnostic Reagent Inhibin A 100 Tests/Kit Fertility Hormone Assay for Clinical In Vitro Diagnostic
CE ISO13485 Bottle Diagnostic Reagent Inhibin A 100 Tests/Kit Fertility Hormone Assay for Clinical In Vitro Diagnostic SPECIMEN COLLECTION Sample material: Serum/Plasma/Whole Blood Collect samples using standard procedures. Store at 2-8℃: 24 hours, for longer storage periods: freeze to below - 20℃ Avoid repeated freezing and thawing cycles, stored samples should be thoroughly mixed prior to use (Vortex mixer) CLIA Reagents of Fertility Hormone(Inhibin A) Test Item Inhibin A
High-sensitivity reagent kit aldosterone (ALD) for Automatic immunoassay analyzer in DIABETES
High-sensitivity reagent kit aldosterone (ALD) for Automatic immunoassay analyzer in DIABETES CLIA Reagents of DIABETES (ALD) Test item ALD Specification 100 Test/Box for CIA series 24 Test/Box for POCT Principle sandwich method Component Magnetic Beads Calibrator Low Calibrator High ALD Anti Control 1 Control 2 Accessories Required But Not Provided Substrate Washing solution Sample material serum Sample volume More than 200μL Storage 2-8℃ The three items of hypertension
Chemiluminescence Reagent Kit FSH Follicle-stimulating Hormone Immunoassay High-sensitivity Fertility Hormone Assay Kit
Chemiluminescence Reagent Kit FSH Follicle-stimulating Hormone Immunoassay High-sensitivity Fertility Hormone Assay Kit Reagent Integral for 100 determinations: Magnetic beads:BSA buffer with magnetic beads complex with goat anti-FITC; 1×3.0mL Calibrator A-F: BSA buffer with different levels of FSH antigen; 6×0.15mL FSH Anti:FSH antibody complex labeled by FITC; FSH antibody complex labeled by AP; Buffer with BSA; 1×6.0mL All reagents are provided ready-to-use. CLIA Reagents
100 Test Vitamin B12 Reagents for Automatic Immunoassay Analyzer in Human Serum Samples
Product description 100 Test Vitamin B12 Reagents for Automatic Immunoassay Analyzer in Human Serum Samples Calibrator L, Calibrator H: Tris buffer (0.15M, PH7.5) containing 0.5% BSA and 0.05% proclin300 was added with different amounts of VB12, the concentrations of VB12 were 250.0pg/mL and 900.0pg/mL, respectively. Quality control product 1, quality control product 2: Tris buffer (0.15M, PH7.5) containing 0.5% BSA was added with different amounts of VB12, and the concentrat
Anemia Reageats Folate(FA) Reagents for Automatic Immunoassay Analyzer in Human Serum Samples
Product description Anemia Reageats Folate(FA) Reagents for Automatic Immunoassay Analyzer in Human Serum Samples Calibrator L (freeze-dried) and calibrator H (freeze-dried): 0.15m Tris buffer (ph7.5) containing 0.5% BSA and 0.05% proclin300 and different contents of folic acid (concentrations are 2.5ng/ml and 10.0ng/ml respectively). Quality control product 1 (freeze-dried) and quality control product 2 (freeze-dried): 0.15m Tris buffer (ph7.5) containing 0.5% BSA and 0.05%
Anemia Reageats Ferritin Reagents for Automatic Immunoassay Analyzer in Human Serum Samples
Product description Anemia Reageats Ferritin Reagents for Automatic Immunoassay Analyzer in Human Serum Samples Ferritin high and low calibrators: there are two different concentrations of high and low, 40ng/mL and 400ng/mL, respectively, with different amounts of ferritin (FERRITIN) antigen (derived from human cell culture) added. 5% bovine serum albumin (BSA) in Tris buffer (0.15M, pH 7.5). Ferritin control 1, quality control 2: There are two different concentrations of
Somatomedin C(IGF-1) Reagents for Automatic Immunoassay Analyzer in Human Serum Samples
Product description Somatomedin C(IGF-1) Reagents for Automatic Immunoassay Analyzer in Human Serum Samples The full name of IGF-1 is insulin-like growth factor 1. IGF-1, also known as "growth-promoting factor" (ie somatomedin C), is a polypeptide protein substance similar in molecular structure to insulin. IGF-1 is important for growth in infants and for continued anabolic effects in adults. Test item IGF-1 Specification 100 Test/Box for CIA series Component Magnetic Beads
Alpha Fetoprotein(AFP) Reagents for Automatic Immunoassay Analyzer in Human Serum Samples
Product description Alpha Fetoprotein(AFP) Reagents for Automatic Immunoassay Analyzer in Human Serum Samples 1. Calibrator: There are two different concentrations, high and low, and buffers containing bovine serum albumin (BSA) with different amounts of alpha-fetoprotein antigen are respectively added; 2. Quality control material: There are two different concentrations, high and low, and buffers containing bovine serum albumin (BSA) with different amounts of alpha-fetoprotei
F-hCGβ Reagents for Automatic Immunoassay Analyzer in Human Serum Samples
Product description F-hCGβ Reagents for Automatic Immunoassay Analyzer in Human Serum Samples High and low value calibrators: 1 bottle each, added with different amounts of F-hCGβ recombinant antigen (E. coli) containing 0.5% BSA, 0.05% proclin300 Tris buffer (0.15M, PH7.0), two calibrations The concentration of the F-hCGβ antigen of the product was 80mIU/mL and 15mIU/mL, respectively; F-hCGβ Anti-Reagent: 1 vial, Fluorescein isothiocyanate (FITC)-labeled mouse monoclonal