SICK
SICK Gas Analyzers TRANSIC100LP
Specs at a glance Measured variables O2 Measuring range O2: 0 ... 5 Vol.-% / 0 ... 100 Vol.-% Ambient temperature range –20 °C ... +60 °C
SICK VICOTEC320 air quality measuring device
Specs at a glance Measured variables Visibility (K-value), NO, NO2, NOx, CO, Temperature Measuring range K-value: 0 ... 15 km⁻¹ / 0 ... 200 km⁻¹ NO: 0 ... 20 ppm / 0 ... 45 ppm NO2: 0 ... 1 ppm / 0 ... 5 ppm CO: 0 ... 100 ppm / 0 ... 300 ppm Temperature: -25 ... +55 °C / -25 ... +75 °C Conformities ASTRA "Guideline - Ventilation of Road Tunnels" (2008) RABT 2006 RVS 09.02.22
SICK Dust Measuring Devices DUSTHUNTER SP100 DUSTHUNTER T50 DUSTHUNTER SB100 FWE200 ZIRKOR200 GM700 ZIRKOR302 SW102 GHG-control GM35
Specs at a glance Process temperature -40 °C ... +220 °C Measuring range Scattered light intensity: 0 ... 7.5 mg/m3 / 0 ... 3,000 mg/m3 Measuring ranges freely selectable; nine measuring ranges pre-configured (0 ... 7.5/15/45/75/150/225/375/1,000/3,000 mg/m3) Conformities TÜV type test Suitability tested acc. DIN EN 15267-1 (2009), DIN-EN 15267-2 (2009), DIN EN 15859 (2010), DIN EN 14181 (2014) Certified for use as Dust monitor and Leak monitor for filter control downstream
SICK HISIC450 overheight detector
Specs at a glance Measured variables Overheight Measuring range ≤ 100m for outdoor management Ambient temperature range –25 °C ... +55 °C Degree of protection IP67
SICK Visual range measuring devices: VISIC620 VISIC620-2111
Description Visibility measuring device incl. connecting cable, with male connector, length 5 m, with RS-485 interface and binary input Measured values Standard visual range, K-value Maximum number of measurands 1 Measurement principles Scattered light forward Spectral range 640 nm ... 660 nm Laser, protection class 2, power < 1 mW Measuring ranges Standard visual range 10 ... 500 m / 10 ... 16,000 m Output range freely adjustable Response time (t90) 2 s ... 300 s Accuracy ±
SICK Gas Analyzers MERCEM300Z emission monitoring solution MERCEM300Z SMC9015 MCS100FT-C MKAS SMC9021F MCS100E HW-C SMC9004H
MERCEM300Z emission monitoring solution Specs at a glance Measured variables Hg Ambient temperature range MERCEM300Z: –20 °C ... +50 °C MERCEM300Z Indoor: +5 °C ... +35 °C Process temperature ≤ +1,300 °C
SICK Gas Analyzers METPAX300
Gas Analyzers METPAX300
SICK Dust Measuring Devices DUSTHUNTER SP30 DUSTHUNTER SB50 Combiprobe CP100 DUSTHUNTER T100 DUSTHUNTER SF100 DUSTHUNTER C200 DUSTHUNTER SB30
Specs at a glance Process temperature -40 °C ... +220 °C Measuring range Scattered light intensity: 0 ... 7.5 mg/m3 / 0 ... 3,000 mg/m3 Measuring ranges freely selectable; nine measuring ranges pre-configured (0 ... 7.5/15/45/75/150/225/375/1,000/3,000 mg/m3) Conformities TÜV type test Suitability tested acc. DIN EN 15267-1 (2009), DIN-EN 15267-2 (2009), DIN EN 15859 (2010), DIN EN 14181 (2014) Certified for use as Dust monitor and Leak monitor for filter control downstream
SICK MARSIC200 Gas Analyzers MINESIC700 TBS
SICK MARSIC200 Gas Analyzers MINESIC700 TBS
SICK Gas Analyzers PowerCEMS50 MCS300P HW MCS100E PD SFDS MCS100E HW MCS100E CD MCS100FT
Gas Analyzers PowerCEMS50 MCS300P HW MCS100E PD SFDS MCS100E HW MCS100E CD MCS100FT
SICK VISIC50SF smoke detector Early and reliable fire detection in tunnels
Specs at a glance Measured variables Visibility (K-value) Measuring range Visibility (K-value): 0 ... 150 km⁻¹ Temperature measurement (option): -30 ... +70 °C Ambient temperature range –20 °C ... +55 °C Conformities ASTRA "Guideline - Fire Detection in Road Tunnels" (2007) RABT 2006
SICK Gas Analyzers MINESIC700 GHG
Gas Analyzers MINESIC700 GHG
SICK Gas Analyzers SMC9004M System for ambient-temperature gas analysis in the cement industry
System for ambient-temperature gas analysis in the cement industry This product can meet system requirements to provide continuous monitoring of CO, O2, NOx during the production process. Based on a system of manual control for operations such as sampling, back-purging, and draining, the system’s internal control unit can automatically perform the tasks of sampling, back-purging, and draining to reduce the workload of maintenance staff.
SICK Gas Analyzers SMC209C SMC209 C, the extractive flue gas humidity analyzer
SMC209 C, the extractive flue gas humidity analyzer The SMC902 C flue gas humidity analyzer is designed for use in the continuous emission monitoring systems of stationary pollutant emitters to measure flue gas humidity. The device utilizes an anti-wear and anti-corrosion installation that overcomes the high-temperature flue gas problems of particulates, high temperature, and acid corrosion. It can remain on-line and provide long-term stable measurement of flue gas humidity
SICK Gas Analyzers SMC9004D System for low-temperature gas analysis in the cement industry
This product can meet system requirements to provide continuous monitoring of CO during the production process. Based on a system of manual control for operations such as sampling, back-purging, and draining, the system’s internal control unit can automatically perform the tasks of sampling, back-purging, and draining to reduce the workload of maintenance staff.
SICK Gas Analyzers MARSIC280 MARSIC200 MARSIC280 emission monitoring solution Reliably on the right course
Specs at a glance Measured variables CO2, SO2 Measuring range CO2: 0 ... 25 Vol.-% SO2: 0 ... 100 ppm / 0 ... 500 ppm Conformities MARPOL Annex VI and NTC 2008 – MEPC.177(58) Guidelines for exhaust gas cleaning systems – MEPC.340(77) DNV Rules for Type Approvals (DNVGL-CG-0339)
SICK PowerCEMS100 emission monitoring solution High-performance, future-proof CEMS for emission measurement
Specs at a glance Measured variables CO, NO, NO2, NOx, SO2, CH4, N2O, CO2, O2 Ambient temperature range Indoor: +5 °C ... +40 °C Can be expanded on the system side if necessary Indoor with cooling unit: +5 °C ... +50 °C Can be expanded on the system side if necessary Outdoor: –20 °C ... +50 °C Can be expanded on the system side if necessary
SICK Shelter Solutions process gas analyzer Space and protection for measurement and analysis technology
Field of application Shelter solutions are primarily used to protect the installed analyzer systems from extreme ambient conditions such as heat, cold, dust, wind, earthquakes and corrosive or explosive atmospheres. They also offer advantages for transport as well as on-site installation and maintenance. At the factory, everything is coordinated and pre-installed in the shelter in a clear manner. Each shelter can be equipped to fit individual customer requirements.
SICK Digital analyzer solutions SMC900 Data monitoring and control system for continuous emissions monitoring systems
The SMC900 collects, processes, computes, saves, reports, and transmits data. It can transmit data via modem (modem or GPRS) to environmental protection authorities and enables users to carry out remote monitoring and link it into the distributed control system.
SICK TRANSIC Extractive process gas analyzer
Specs at a glance Measured variables O2 Measuring range O2: 0 vol. % ... 5 vol. % 0 vol. % ... 25 vol. % 0 vol. % ... 100 % Ambient temperature range -20 °C ... +60 °C Can be expanded on the system side if necessary