Security Alarm Cable
Exact Cables 10x0.22mm2 Shielded Stranded CCA PVC Insulation Alarm Cable for Industrial
Product Description Shielded Stranded CCA conductor PVC Insulation and Jacket CPR Eca Alarm Cable APPLICATION:These cables are used for installation in signaling and alarm system.This is suitable for the connection of contacts, detectors andsensors.Infra-red as well as micro wave or mixed technology systems to the switch board.Internal wiring of electronic and electrical equipment. PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) unshielded or shieldedConductors Materials: TC/BC
6 Cores Exact Cables 6x0.22mm2 Shielded Stranded CCA Alarm Cable with PVC Insulation
Product Description Shielded Stranded CCA conductor PVC Insulation and Jacket CPR Eca Alarm Cable APPLICATION:These cables are used for installation in signaling and alarm system.This is suitable for the connection of contacts, detectors andsensors.Infra-red as well as micro wave or mixed technology systems to the switch board.Internal wiring of electronic and electrical equipment. PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) unshielded or shieldedConductors Materials: TC/BC
Exact Cables 8X0.5mm Brown Unshielded CPR Alarm Cable En50575 IEC6032-1 for UK Market
Product Description Solid 8X0.5mm Brown Unshielded or Shielded CCA/Tinned Copper/Copper/TCCA CPR Alarm Cable EN50575 IEC6032-1 for UK market PRODUCT DESCRIPTION: Structure:1/0.5mm unshielded or shieldedMaterials: CCA/TC/BC/TCCASpecification: 1/0.50mmCable core: 2/4/6/8/10/12/14/16/18/20 CoresInsulation:PVCRip cord: Nylon FibreShield:Al/foilDrain wire:1*0.5mmJacket:PVC/LSF/LSZH/LSOH/LSNHAPPLICATION:These cables are used for installation in signaling and alarm system.This is
CPR Eca Alarm Cable with PVC Jacket and 2x0.22mm2 Shielded Stranded CCA Conductor
Product Description Specification Part N0.DescriptionItemConductor Spec.InsulationJacketPackingNom Thick. (mm)Nom Diam (mm)Nom Thick. (mm)Nom Diam (mm)ECAC001TC or BC or CCA or TCCA or TCCAM, Screened or Unscreened; Rip cord or NO. Drain wire or NO.2x0.22 mm22×7/0.20.221.050.453.1Box Coil DrumPaper reel Plastic reel Wooden reelECAC0024x0.22 mm24×7/0.20.221.050.453.4ECAC0036x0.22 mm26×7/0.20.221.050.54.1ECAC0048x0.22 mm28×7/0.20.221.050.54.5ECAC00510x0.22 mm210×7/0.20.221.050
Unshielded Shielded CCA/TC/BC/TCCA Stranded Composite Alarm Cable for Industrial
Product Description Unshielded or Shielded CCA/TC/BC/TCCA Stranded 0.22+0.75, 0.22+0.5 Composite CPR Alarm Security Cable PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) & (0.5mm2) & (0.75mm2) unshielded or shieldedMaterials: TC/BC/CCA/TCCA/TCCAMSpecification: 7 stranded,0.18mm/0.19mm/0.20mmCable core: 2/4/6/8/10/12/14/16/18/20/24/30 CoresInsulation:PVC/LSF/LSZH/LSOH/LSNHRip cord: Nylon FibreShield:Al/foilDrain wire:7*0.2mmJacket:PVC/LSF/LSZH/LSOH/LSNHApplication:These cables
Exact Cables 2x0.22mm2 Unshielded Stranded CCA LSF Insulation CPR Eca Alarm Cable
Product Description 2x0.22mm2 Unshielded Stranded CCA conductor LSF Insulation and Jacket CPR Eca Alarm Cable PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) unshielded or shieldedMaterials: TC/BC/CCA/TCCA/TCCAMSpecification: 7 stranded,0.18mm/0.19mm/0.20mmCable core: 2/4/6/8/10/12/14/16/18/20 CoresInsulation:PVC/LSF/LSZH/LSOH/LSNHRip cord: Nylon FibreShield:Al/foilDrain wire:7*0.2mmJacket:PVC/LSF/LSZH/LSOH/LSNHApplication:These cables are used for installation in signaling and
Unshielded Shielded CPR Alarm Cables The Trusted Choice for Industrial and Security
Product Description Unshielded or Shielded CCA/TC/BC/TCCA Stranded or Solid Alarm Security Cable APPLICATION: These cables are used for installation in signaling and alarm system.This is suitable for the connection of contacts, detectors andsensors.Infra-red as well as micro wave or mixed technology systems to the switch board.Internal wiring of electronic and electrical equipment. PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) unshielded or shieldedConductors Materials: TC/BC
4x0.22 mm2 CPR Stranded Solid Communication Cable for Alarm and Security Application
Product Description Unshielded or Shielded CCA/Tinned Copper/Copper/TCCA Stranded or Solid CPR Alarm Security Cable PRODUCT DESCRIPTION:Multi-roots lay-up bare copper(tinned copper)conductorPVC insulationMulti-cores lay-upRip cordFlame retardant PVC or non-migration PVC or low-smoke POE jacket ELECTRICALCHARACTERISTICSVoltage Test:1500Vcc/minMinimum insulation resistance at 20ºC:1500MΩ.kmMutual capacity of the pairs:
Exact Cables 6x0.22mm2 Shielded Alarm Cable with TCCA Drain Wire and PVC Outer Sheath
Product Description Shielded alarm cable 0.22mm2 Stranded conductors 7*0.2mm TCCA White PVC Outer Sheath APPLICATION: These cables are used for installation in signaling and alarm system.This is suitable for the connection of contacts, detectors andsensors.Infra-red as well as micro wave or mixed technology systems to the switch board.Internal wiring of electronic and electrical equipment. PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) unshielded or shieldedConductors Materials
Stay Connected with Exact Cables' CCA/Tinned Copper/Copper/TCCA Communication Cables
Product Description South Africa UK Market Unshielded or Shielded CCA/Tinned Copper/Copper/TCCA Stranded or Solid CPR Alarm Cable Security Cable PRODUCT DESCRIPTION:Multi-roots lay-up bare copper(tinned copper)conductorPVC insulationMulti-cores lay-upRip cordFlame retardant PVC or non-migration PVC or low-smoke POE jacket ELECTRICALCHARACTERISTICSVoltage Test:1500Vcc/minMinimum insulation resistance at 20ºC:1500MΩ.kmMutual capacity of the pairs:
20 Cores Shielded Alarm Cable 20x0.22mm2 Stranded Conductors 7*0.2mm TCCA White PVC Outer Sheath
Product Description Shielded alarm cable 0.22mm2 Stranded conductors 7*0.2mm TCCA White PVC Outer Sheath APPLICATION: These cables are used for installation in signaling and alarm system.This is suitable for the connection of contacts, detectors andsensors.Infra-red as well as micro wave or mixed technology systems to the switch board.Internal wiring of electronic and electrical equipment. PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) unshielded or shieldedConductors Materials
8 Core Shielded Alarm Cable 0.22mm2 Stranded Conductors TCCA White PVC Outer Sheath
Product Description Shielded alarm cable 0.22mm2 Stranded conductors 7*0.2mm TCCA White PVC Outer Sheath APPLICATION: These cables are used for installation in signaling and alarm system.This is suitable for the connection of contacts, detectors andsensors.Infra-red as well as micro wave or mixed technology systems to the switch board.Internal wiring of electronic and electrical equipment. PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) unshielded or shieldedConductors Materials
Shielded Alarm Cable 24x0.22mm2 7*0.2mm TCCA Stranded Conductors White PVC Outer Sheath
Product Description Shielded alarm cable 0.22mm2 Stranded conductors 7*0.2mm TCCA White PVC Outer Sheath APPLICATION:These cables are used for installation in signaling and alarm system.This is suitable for the connection of contacts, detectors andsensors.Infra-red as well as micro wave or mixed technology systems to the switch board.Internal wiring of electronic and electrical equipment. PRODUCT DESCRIPTION:Structure:24AWG(0.22mm2) unshielded or shieldedConductors Materials: