Industrial Wire and Cable
UL2464 3P×24AWG Flexible Industrial Cable Bare Copper Stranded with SR-PVC Insulation and PVC Jacket 300V 80℃
UL2464 3P×24AWG Flexible Industrial Cable Bare Copper Stranded with SR-PVC Insulation and PVC Jacket 300V 80℃ ITEM 3P×24AWG(44/0.08B)+AB CONDUCTOR Material Bared copper stranded Size 44/0.08±0.008mm O.D.( Ref ) 0.61mm INSULATION Material SR-PVC Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.15±0.05mm TWISTED OD .(Ref) 2.30mm CABLING Filler Cotton+Nylon Material Al-mylar(foil face out) BRAID Material Tinned copper Size 0.10±0.008mm(80% min.) JACKET
UL2725 3P×26AWG Flexible Industrial Cable Tinned Copper Stranded With HDPE Insulation / PVC Jacket 30V 80℃
UL2725 3P×26AWG Flexible Industrial Cable Tinned Copper Stranded with HDPE Insulation and PVC Jacket 30V 80℃ ITEM 3P×26AWG(19/0.10T) CONDUCTOR Material Tinned copper stranded Size 19/0.10±0.008mm O.D.(Ref) 0.50mm INSULATION Material HDPE Min.average thickness 0.13mm Min.thickness at any point 0.08mm O.D. 0.80±0.08mm TWISTED O.D. 1.60mm CABLING Filler Cotton Draid wire Tinned copper stranded 19/0.10±0.008mm Material Al-mylar(face in) Assembly 3P×26AWG(19/0.10T) JACKET Material
UL2464 6C×20AWG Flexible Industrial Cable Tinned Copper Stranded with SR-PVC Insulation and PVC Jacket 300V 80℃
UL2464 6C×20AWG Flexible Industrial Cable Tinned Copper Stranded with SR-PVC Insulation and PVC Jacket 300V 80℃ ITEM 6C×20AWG(65/0.10T)+WDB CONDUCTOR Material Tinned copper stranded+nylon Size 65/0.10±0.008mm O.D.( Ref ) 0.98mm INSULATION Material SR-PVC Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.50±0.10mm CABLING Filler cotton Material Nonwoven tape Assembly 6C×20AWG(65/0.10T)+WD DRAIN Material Tinned copper stranded Size 19/0.127±0.008mm BRAID
UL20549 5C×16AWG Flexible Industrial Cable Tinned Copper Stranded with SR-PVC Insulation and PUR Jacket 300V 80℃
UL20549 5C×16AWG Flexible Industrial Cable Tinned Copper Stranded with SR-PVC Insulation and PUR Jacket 300V 80℃ ITEM 5C×16AWG(105/0.127T) CONDUCTOR Material Tinned copper stranded Size 105/0.127±0.008mm O.D.( Ref ) 1.55mm INSULATION Material PVC Min.average thickness 0.38mm Min.thickness at any point 0.33mm O.D. 2.40±0.10mm CABLING Filler Cotton Assembly 5C×16AWG(105/0.127T) JACKET Material PUR Min.average thickness 0.76mm Min.thickness at any point 0.61mm O.D. 8.40±0.25mm
UL2725 4C×22AWG Flexible Industrial Cable Tinned Copper Stranded with SR-PVC Insulation and PVC Jacket 30V 80℃
UL2725 4C×22AWG Flexible Industrial Cable Tinned Copper Stranded with SR-PVC Insulation and PVC Jacket 600V 105℃ ITEM 4C×22AWG(43/0.10T)+W CONDUCTOR Material Tinned copper stranded Size 43/0.10±0.008mm O.D.( Ref ) 0.76mm INSULATION Material SR-PVC Min.average thickness 0.18mm Min.thickness at any point 0.13mm O.D. 1.20±0.05mm CABLING Filler Cotton Material Non-woven Assembly 4C×22AWG(43/0.10T) JACKET Material PVC( flexible ) Min.average thickness 0.50mm Min.thickness at any
UL2586 Cable 3C×1.3mm2 Flexible Industrial Cable 600V 105℃
UL2586 3C×1.3mm2 Robot Cable Bared Copper Stranded with PVC Insulation and PVC Jacket 600V 105℃ ITEM (3C×1.3mm2(168/0.10B)+AB)+AB CONDUCTOR Material Bare Copper Stranded Size 168/0.10±0.008mm O.D.(Ref) 1.60mm INSULATION Material PVC Min.average thickness 0.50mm Min.thickness at any point 0.40mm O.D. 2.70±0.10mm CABLING-1 Assembly 3C×1.3mm2(168/0.10B)+A Filler Cotton Material Al-mylar(face out) BRAID-1 Material Tinned copper Size 0.10mm ( 80% min.) CABLING-2 Assembly 3C×1.3mm2
UL2517 15C×26AWG Bare Copper Stranded Industrial Flexible Cable With SR-PVC Insulation PVC Jacket 300V
UL2517 15C×26AWG Bare Copper Stranded Industrial Flexible Cable with SR-PVC Insulation PVC Jacket 300V 105℃ ITEM 15C×26AWG(7/0.16B) CONDUCTOR Material Bare copper stranded Size 7/0.16±0.008mm O.D.(Ref) 0.48mm INSULATION Material SR-PVC Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.00±0.05mm CABLING Filler PP rope Material Non-woven tape Assembly 15C×26AWG(7/0.16B) BRAID Material Tinned copper Size 0.12mm(80% min.) JACKET Material PVC Min.average
UL2586 3C×24AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 600V FT-1
UL2586 3C×24AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 600V FT-1 ITEM 3C×24AWG(7/0.20T) CONDUCTOR Material Tinned copper stranded Size 7/0.20±0.008mm O.D.( Ref ) 0.60mm INSULATION Material PVC Min.average thickness 0.76mm Min.thickness at any point 0.69mm O.D. 2.20±0.10mm CABLING Assembly 3C×24AWG(7/0.20T) JACKET Material PVC Min.average thickness 0.90mm Min.thickness at any point 0.72mm O.D. 6.70±0.20mm Application: Internal wring or
UL2586 3C×8AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 600V FT-1
UL2586 3C×8AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 600V FT-1 ITEM 3C×8AWG(168/0.254T) CONDUCTOR Material Tinned copper stranded Size 168/0.254±0.008mm O.D.( Ref ) 4.20mm INSULATION Material PVC Min.average thickness 0.76mm Min.thickness at any point 0.69mm O.D. 5.80±0.20mm CABLING Material Filler Material Paper tape Assembly 3C×8AWG(168/0.254T) JACKET Material PVC Min.average thickness 1.14mm Min.thickness at any point 0.92mm O.D.
UL2586 3C×6AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V VW-1
UL2586 3C×6AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V VW-1 Construction Conductor Tinned copper Cross section 6AWG Construction 182/0.32mm Strand Dia. 5.20mm ( Ref. ) Insulation PVC Nom.Thickness 1.30mm Min.Thickness 1.04mm Insulation Dia. 8.0±0.30mm Insulation colour 1~2 orange with black number 1~2 3.Gray Assembly 3C+Filler Material Non woven Jacket PVC Nom.Thickness 1.52mm Min.Thickness 1.22mm Outer Dia. 21.0±0.60mm Colour
UL2517 11C×22AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V
UL2517 11C×22AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V ITEM 11C×22AWG(17/0.16T) CONDUCTOR Material Tinned copper stranded Size 17/0.16±0.008mm O.D.( Ref ) 0.76mm INSULATION Material PVC Min.average thickness 0.26mm Min.thickness at any point 0.18mm O.D. 1.28±0.05mm CABLING Filler PP rope Material Al-mylar( Foil facing out ) Assembly 11C×22AWG(17/0.16T) DRAIN WIRE Material Tinned copper stranded Size 17/0.16mm BRAID Material
UL2464 9C×24AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V
UL2464 9C×24AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V Construction Conductor Tinned copper stranded Cross section 24AWG Construction 7/0.20mm Strand Dia. 0.60mm Insulation PVC Nom.Thickness 0.23mm Min.Thickness 0.18mm Insulation Dia. 1.10±0.08mm Insulation colour 1.black 2.white 3.red 4.green 5.brown 6.blue 7.orange 8.yellow 9.purple Filler Optional Drian Tinned copper , 7/0.20mm Material Al-mylar(foil face in,≥25%) Assembly 8C
UL2464 7Cx14AWG Tinned Stranded Copper Cable With PVC Insulation / PVC Jacket 300V
UL2464 7Cx14AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V Construction Conductor Bare copper stranded Cross section 14AWG Construction 50/0.254mm Strand Dia. 2.07mm Insulation PVC Nom.Thickness 0.38mm Min.Thickness 0.33mm Insulation Dia. 3.00±0.15mm Insulation colour 1.black 2.white 3.red 4.green 5.brown 6.blue 7.orange Covering PVC Nom.Thickness 0.76mm Min.Thickness 0.61mm Outer Dia. 10.80±0.35mm Colour Gray Braid Tinned copper,0
UL2464 6C×26AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V
UL2464 6C×26AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket 300V Construction Conductor Tinned Copper Stranded Cross section 26AWG Construction 7/0.16mm Strand Dia. 0.48mm ( Ref. ) Insulation PVC Nom.Thickness 0.23mm Min.Thickness 0.18mm Insulation Dia. 1.00±0.05mm Insulation colour 1.black , 2.brown , 3.red , 4.orange , 5.yellow , 6.green Filler Optional Assembly 6C×26AWG Material AL-mylar(foil face out) ,≥ 25% Braid Tinned Copper Size 0
UL2464 5C×22AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket
UL2464 5C×22AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket Construction Conductor Tinned copper stranded Cross section 22AWG Construction 7/0.254mm Strand Dia. 0.76mm Insulation PVC Nom.Thickness 0.23m Min.Thickness 0.18mm Insulation Dia. 1.30±0.08m Insulation colour 1.black 2.red 3.orange 4.yellow 5.green Filler optional Material Al-mylar(facing out) Assembly 5C×22AWG+A Braid Tinned copper Size 0.10mm ,80%Min. Jacket PVC Nom.Thickness 0
UL2464 4C×16AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket
UL2464 4C×16AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket Construction Conductor Tinned Copper Stranded Cross section 16AWG Construction 26/0.254mm Strand Dia. 1.49mm ( Ref. ) Insulation PVC Nom.Thickness 0.38mm Min.Thickness 0.33mm Insulation Dia. 2.30±0.10mm Insulation colour 1.red 2.black 3.brown 4.blue Filler Optional Material Al-mylar(foil face out) ,≥ 25% Drain Tinned Copper Stranded , 26/0.16mm Assembly 4C×16AWG+A Braid Tinned
UL20327 3Cx16AWG Tinned Copper Stranded Industrial Flexible Cable with XLPE Insulation TPE Jacket
UL20327 3Cx16AWG Tinned Copper Stranded Industrial Flexible Cable with XLPE Insulation TPE Jacket Construction Conductor Tinned Copper Stranded Cross section 16AWG Construction 105/0.127mm Strand Dia. ( Ref. ) 1.50mm Insulation XL-PE Nom.Thickness 0.38mm Min.Thickness 0.33mm Insulation Dia. 2.40±0.10mm Insulation colour 1.black 2.red 3.yellow Filler Optional Material Non-woven ,≥ 25% Twist 3C×16AWG+W Jacket TPE(UV resistance ) Nom.Thickness 0.76mm Min.Thickness 0.61mm Outer
UL2464 2P×20AWG Tinned Copper Stranded Industrial Flexible Cable with SR-PVC Insulation PVC Jacket
UL2464 2P×20AWG Tinned Copper Stranded Industrial Flexible Cable with SR-PVC Insulation PVC Jacket ITEM 2P×20AWG(105/0.08T)+ADB CONDUCTOR Material Tinned copper stranded+Nylon Size 105/0.08±0.008mm+250D O.D.( Ref ) 1.05mm INSULATION Material SR-PVC Min.average thickness 0.23mm Min.thickness at any point 0.18mm O.D. 1.50±0.10mm TWISTED O.D.( Ref ) 3.00mm CABLING Filler cotton Material Al-mylar(face out) Assembly 2P×20AWG(105/0.08T)+AD DRAIN Material Tinned copper stranded Size
3Cx0.34mm2 Bare Copper Wire 300V Copper Stranded Cable UL2517
UL2517 3Cx0.34mm2 Bare Copper Stranded Industrial Flexible Cable with PVC Insulation PVC Jacket Construction Conductor Bare copper stranded Cross section 0.34mm2 Construction 65/0.08mm Strand Dia. 0.74mm Insulation PVC Nom.Thickness 0.23mm Min.Thickness 0.18mm Insulation Dia. 1.25±0.10mm Insulation colour 1.brown 2.blue 3.black Filler Optional Material Paper tape,≥25% Assembly 3Cx0.34mm2+P Jacket PVC Nom.Thickness 0.76mm Min.Thickness 0.61mm Outer Dia. 4.50±0.15mm Application
UL1007 28AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation 105℃ 300V
UL1007 28AWG Tinned Copper Stranded Industrial Flexible Cable with PVC Insulation 80℃ 300V Construction Conductor Tinned copper stranded Cross section 28AWG Construction 7/0.127mm Strand Dia. 0.38mm Insulation PVC Nom.Thickness 0.38mm Min.Thickness 0.33mm Insulation Dia. 1.20±0.05mm Insulation colour black Application: Internal wring or external interconnection of electronic equipment. These cables are appropriate for flexible use with medium mechanical stresses, and free